Eaton Crouse-Hinds Ex-CELL XLVPS1614083B Enclosure - Hazardous Location Rated
Part Number: XLVPS1614083B
Manufacturer
Eaton Crouse-Hinds
Part number
XLVPS1614083B
Quick Summary
Eaton Crouse-Hinds Ex-CELL XLVPS1614083B enclosure provides rugged protection for electrical gear in hazardous environments. If you’re facing tight spaces, frequent maintenance, or strict regulatory pressure, this enclosure helps you keep wiring organized and compliant. It carries NEC/CEC compliance and hazardous-location approvals, including Class I Zone 1, Class II Division 2, and Class I Division 2, along with a NEMA rating of 3S–4, enabling safer operation in demanding conditions. The painted mild steel body delivers durable enclosure performance, while three gland plates and a hinged, bolted cover support straightforward installation and service. Vertical lugs simplify mounting on varied frame configurations, delivering reliability across chemical plants, oil refineries, and offshore facilities.
Product Information
Extended Description
XLVPS1614083B Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 16" x 14" x 8", Painted mild steel, 3 gland plates, Cover fixed with hinges and bolts, Vertical lugs
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLVPS1614083B
Product Length/Depth
14 in
Product Height
16 in
Product Width
8 in
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Zone 1 Class II, Division 2 Class I, Division 2
NEMA Rating
3S 4
Material
Painted mild steel
Enclosure size
16" x 14" x 8"
Number of gland plates
3
Type
Vertical lugs
Special features
Cover fixed with hinges and bolts
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
ENK10673 Ex-Cell Operating Instructions
Eaton Specification Sheet - XLVPS1614083B
Feature: Rugged construction with painted mild steel, sized at 16" x 14" x 8", three gland plates, hinge-and-bolt cover, and vertical lugs. Business impact: Delivers durable protection against corrosion, impact, and environmental exposure in hazardous areas, reducing downtime and maintenance costs. Application: Ideal for chemical processing, oil and gas, and mining environments where reliable enclosure integrity is essential. Long-tail keywords: Ex-CELL enclosure, painted mild steel enclosure, 16x14x8 enclosure, vertical lug mounting. Feature: Hazardous-location compliance with NEC/CEC standards and area classifications. Business impact: Ensures regulatory alignment and risk reduction, simplifying audits and permitting. Application: Suitable for Class I Zone 1 and Class II Division 2 installations in refineries and offshore facilities. Long-tail keywords: Class I Zone 1, Class II Division 2, NEC/CEC compliance. Feature: Practical design for serviceability with 3 gland plates and hinged cover. Business impact: Accelerates wiring and maintenance tasks, cuts field labor time, and improves reliability. Application: Fastened closure supports quick entry for routine inspections in demanding environments. Long-tail keywords: three gland plates, hinged cover, quick-entry enclosure. Feature: Mounting versatility via vertical lugs and compatibility with Ex-CELL catalog configurations. Business impact: Reduces installation complexity and enables flexible mounting on standard frames. Application: Fits diverse industrial layouts in plants and offshore platforms. Long-tail keywords: vertical lugs, Ex-CELL compatibility, mounting versatility. Feature: NEMA 3S 4 protection levels and area-classified suitability. Business impact: Provides weather and ingress protection for outdoor or harsh indoor spaces, supporting long-term asset protection. Application: Outdoor substations, process plants, and remote installations. Long-tail keywords: NEMA 3S/4, enclosure protection, hazardous-location enclosure.
Get a Quick Quote for a Eaton Crouse-Hinds XLVPS1614083B
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLVPS1614083B?
Enquire Now
FAQs
This enclosure is designed for Class I Zone 1 and Class II Division 2 environments. It features a hinged cover, three gland plates, and vertical lugs for straightforward mounting on standard frames. Follow ENK10673 installation instructions to ensure correct sealing, grounding, and wiring practices, minimizing risk and downtime during commissioning.
Key specs include 16 in length, 14 in height, 8 in width, painted mild steel construction, three gland plates, hinged and bolted cover, and vertical lugs. It carries NEC/CEC compliance with hazardous-location ratings and a NEMA rating of 3S/4, making it suitable for demanding industrial environments.
Yes. With Class I Zone 1 and Class II Division 2 approvals, NEC/CEC compliance, and NEMA 3S/4 protection, the XLVPS1614083B is well-suited for offshore platforms, chemical processing, and other hazardous-location facilities where reliable enclosure performance is critical.
The enclosure adheres to NEC/CEC standards with hazardous-area classifications (Class I Zone 1; Class II Division 2; Class I Division 2) and carries a NEMA rating of 3S and 4. It is designed for area classifications of Hazardous/Classified Locations, supporting safe operation and regulatory compliance.
Maintenance benefits include quick access through a hinged cover and three gland plates for flexible wiring, reducing service time. Material choice (painted mild steel) offers durability at a reasonable cost, extending service life in harsh environments and lowering total cost of ownership through fewer replacements and faster downtime recovery.