Eaton Crouse-Hinds XLVPS3024081 Ex-CELL - Class I Zone 1
Part Number: XLVPS3024081
Manufacturer
Eaton Crouse-Hinds
Part number
XLVPS3024081
Quick Summary
Ex-CELL enclosure protects electrical equipment in hazardous locations while enabling reliable control panel installations. Engineers often struggle with enclosures that fail in aggressive environments or fail to meet evolving codes, driving maintenance costs and downtime. This XLVPS3024081 Ex-CELL enclosure meets NEC/CEC compliance with hazardous-location ratings including Class I Zone 1 and Class II Division 2, plus a NEMA 4/3S protection profile for rugged conditions. With a 30" x 24" x 8" footprint, painted mild steel construction, one gland plate, and vertical lugs, it delivers robust physical protection and installation flexibility that help facilities reduce lifecycle costs and support scalable control architectures.
Product Information
Extended Description
XLVPS3024081 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 30" x 24" x 8", Painted mild steel, 1 gland plate, Vertical lugs
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLVPS3024081
UPC
662276749115
Product Length/Depth
24 in
Product Height
30 in
Product Width
8 in
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 2 Class I, Zone 1 Class I, Division 2
NEMA Rating
4 3S
Material
Painted mild steel
Enclosure size
30" x 24" x 8"
Number of gland plates
1
Type
Vertical lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
ENK10673 Ex-Cell Operating Instructions
Eaton Specification Sheet - XLVPS3024081
Painted mild steel construction provides robust durability in dusty, humid, and washdown-prone environments, delivering long-term reliability and reduced maintenance costs. This translates to lower downtime and easier compliance with industrial safety standards in everyday panel-building tasks. The enclosure’s hazardous-location certifications—NEC/CEC with Class I Zone 1 and Class II Division 2 ratings—minimize regulatory risk during design reviews and commissioning, helping systems go live faster in chemical plants, refineries, and mining sites. The NEMA 4 and 3S ratings deliver water and dust ingress protection for outdoor and semi-exposed installations, extending service intervals and lowering preventive-maintenance spend. The 30" x 24" x 8" footprint, 1 gland plate, and vertical-lug configuration simplify wiring, support modular devices, and streamline field upgrades without heavy rework. Finally, the Ex-CELL lineage aligns with catalog and installation resources, accelerating procurement, stocking, and on-site installations across multiple facilities.
Get a Quick Quote for a Eaton Crouse-Hinds XLVPS3024081
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLVPS3024081?
Enquire Now
FAQs
Plan for a 30" x 24" x 8" footprint with a single gland plate and vertical lugs to simplify conduit entries and device mounting. Ensure proper sealing and grounding per NEC/CEC guidelines, and reference ENK10673 Ex-Cell Operating Instructions for wiring practices, gasket integrity, and field modifications. The enclosure is rated for Class I Zone 1 and Class II Division 2, supporting compliant installations in chemical, petrochemical, and mining environments.
The XLVPS3024081 Ex-CELL enclosure carries NEC/CEC compliance with hazardous-location ratings including Class I Zone 1 and Class II Division 2, along with a NEMA 4 and 3S enclosure rating. These certifications support regulatory acceptance for installations in hazardous environments and outdoor or washdown conditions, reducing risk during audits and system handovers.
Yes. With a NEMA 4 and 3S rating, the Ex-CELL enclosure provides dependable protection against water, dust, and certain washdown conditions. Painted mild steel construction adds external durability, enabling reliable operation in outdoor plant areas, weather-exposed spaces, and harsh process environments common in oil, gas, and chemical processing facilities.
The enclosure footprint is 30 inches high, 24 inches deep, and 8 inches wide, with one gland plate provided. The design also features vertical lugs to facilitate mounting. This configuration supports mid-size control panels and straightforward cabling routes, helping minimize wiring complexity and installation time while allowing space for modest device density.
The Ex-CELL XLVPS3024081 delivers a favorable total cost of ownership by reducing downtime through rugged hazardous-location protection, lowering maintenance frequency with durable painted mild steel, and streamlining installation with a simple gland-plate/wiring layout. Regulatory compliance is achieved upfront with NEC/CEC ratings, shortening commissioning, and enabling faster capital project progress.