Eaton Crouse-Hinds XLVS11614081 Ex-CELL enclosure - IP66
Part Number: XLVS11614081
Manufacturer
Eaton Crouse-Hinds
Part number
XLVS11614081
Quick Summary
Ex-CELL enclosure from Eaton Crouse-Hinds protects critical equipment in hazardous locations. It is engineered to withstand corrosion, ingress, and harsh environmental conditions common in chemical plants and oil fields. This model offers a 16" x 14" x 8" footprint in 316L stainless steel with a single gland plate and vertical lugs for flexible mounting. For engineers and procurement teams, predictable performance reduces downtime and asset deterioration. The enclosure carries IECEx/ATEX certifications alongside NEC/CEC compliance, and is rated IP66 with NEMA 4X protection, ensuring safe operation across global sites. By combining rugged materials with straightforward installation and reliable regulatory compliance, XLVS11614081 delivers long-term value, minimizes maintenance costs, and supports safe, compliant automation deployments.
Product Information
Extended Description
XLVS11614081 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 16"x 14" x 8", 316L stainless steel, 1 gland plate, Vertical lugs
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLVS11614081
Product Length/Depth
14 in
Product Height
16 in
Product Width
8 in
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX NEC/CEC
NEC hazardous rating
Class I, Zone 1 Class II, Division 2 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
16"x 14" x 8"
Number of gland plates
1
Type
Vertical lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
ENK10673 Ex-Cell Operating Instructions
Eaton Specification Sheet - XLVS11614081
Feature → Business Impact → Application: 316L stainless steel construction provides exceptional corrosion resistance in aggressive environments, extending service life and reducing replacement costs across chemical, pharmaceutical, and offshore facilities. This translates to lower total cost of ownership while maintaining mechanical integrity in washdown routines and salt spray exposures. Feature → Business Impact → Application: IP66 and NEMA 4X protection guard against dust ingress and powerful water jets, enabling reliable operation in outdoor substations, dockside installations, and washdown zones without compromising enclosure integrity. This reduces unscheduled downtime and maintenance frequency in harsh environments. Feature → Business Impact → Application: IECEx/ATEX and NEC/CEC certifications ensure regulatory compliance for hazardous locations, minimizing compliance risk and accelerating project approvals in oil and gas, petrochemical, and mining sites. Feature → Business Impact → Application: 16" x 14" x 8" enclosure size with 1 gland plate and vertical lugs simplifies wiring, routing, and panel integration, cutting installation time and improving wiring accuracy in compact control rooms or cable-heavy installations. Feature → Business Impact → Application: The Ex-CELL design supports straightforward field retrofits and compatibility with standard gland entries, enabling faster upgrades and reduced commissioning costs for growing automation systems.
Get a Quick Quote for a Eaton Crouse-Hinds XLVS11614081
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLVS11614081?
Enquire Now
FAQs
This enclosure uses vertical lugs for mounting and includes one gland plate, with overall dimensions of 16x14x8 inches. It is designed for surface mounting in hazardous locations and supports straightforward wiring layouts. For best results, follow the ENK10673 installation instructions and reference the datasheet to ensure proper seal integrity and cable entry sequencing.
Yes. The Ex-CELL XLVS11614081 is certified for hazardous/classified locations with IECEx/ATEX and NEC/CEC standards. It also carries IP66 and NEMA 4X protection, ensuring safe operation in environments with dust, water ingress, and corrosive exposure typical of oil & gas, chemical plants, and offshore facilities.
The enclosure measures 16 inches in length, 14 inches in height, and 8 inches in width. It features a single gland plate for entry and vertical lugs for mounting. This configuration supports flexible cable management and compact panel integration in constrained installation spaces.
You can access the Crouse-Hinds Ex-CELL resources, including brochures, installation instructions ENK10673, and the specification sheet for XLVS11614081, through Eaton’s official literature library. These documents provide wiring diagrams, sealant recommendations, and mounting guidance to streamline field commissioning.
The 316L stainless steel construction delivers superior corrosion resistance, reducing replacement intervals and maintenance costs in aggressive environments. IP66/NEMA 4X protection minimizes ingress-related failures, while hazardous location certifications support faster project approvals, lowering downtime during commissioning and routine service.