Eaton Crouse-Hinds XLVS11620121 Ex-CELL enclosure - IP66

Part Number: XLVS11620121
Manufacturer
Eaton Crouse-Hinds
Part number
XLVS11620121

Quick Summary

Eaton Crouse-Hinds Ex-CELL enclosure XLVS11620121 protects electrical gear in hazardous locations. Industrial plants struggle with corrosion, dust ingress, and the cost of noncompliant enclosures. This unit carries IECEx/ATEX and NEC/CEC certifications with IP66 ingress protection and a NEMA 4X rating for durable performance. Choosing a stainless-steel Ex-CELL enclosure reduces maintenance, extends service life, and simplifies compliance across chemical, oil & gas, and water-treatment environments. Its 316L construction offers corrosion resistance in aggressive atmospheres, while a single gland plate supports straightforward cable entry. Logistics and installation benefits come from standard vertical lugs and a compact 16x20x12 size that fits tight spaces.

Product Information

Extended Description

XLVS11620121 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 16" x 20" x 12", 316L stainless steel, 1 gland plate, Vertical lugs
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLVS11620121
Product Length/Depth
20 in
Product Height
16 in
Product Width
12 in
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX NEC/CEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 1 Class II, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
16" x 20" x 12"
Number of gland plates
1
Type
Vertical lugs
Feature: 316L stainless steel construction provides exceptional corrosion resistance in aggressive environments. Business Impact: Extends service life and reduces maintenance costs in chemical processing, oil & gas, and water treatment facilities. Application: Ideal for harsh indoor or outdoor enclosures where humidity, chemicals, or salt spray are present. Feature: Enclosure size 16" x 20" x 12" with a single gland plate. Business Impact: Facilitates clean, organized cable management and simplifies field wiring without adding bulk. Application: Suitable for compact control panels in constrained plant spaces. Feature: IP66 ingress protection and NEMA 4X rating. Business Impact: Delivers reliable dust and water ingress protection, lowering downtime due to enclosure contamination. Application: Critical for hazardous-location installations in process plants. Feature: Area classification for hazardous/classified locations and IECEx/ATEX plus NEC/CEC compliance. Business Impact: Streamlines multi-region approvals, reducing project delays and installation cost. Application: Enables safe operation across global sites with consistent engineering standards. Feature: Vertical lugs and Ex-CELL design enable straightforward mounting and door operation. Business Impact: Improves installation efficiency and maintenance access, reducing labor time. Application: Panel builders and service teams benefit from faster commissioning and easier retrofit work. Industry context: Stainless Ex-CELL enclosures are trusted across chemical, oil & gas, water/wastewater, and energy sectors for long-term reliability and regulatory alignment.

Get a Quick Quote for a Eaton Crouse-Hinds XLVS11620121

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLVS11620121? Enquire Now

FAQs

For safe, compliant deployment, plan for the 16" x 20" x 12" Ex-CELL enclosure's vertical lug mounting and one gland plate, which simplifies cable entry. Ensure enclosure orientation allows for proper drainage and access to internal components. Verify a compatible gland kit and sealants per IECEx/ATEX and NEC/CEC requirements. Regular inspection schedules will preserve IP66 and 4X performance in harsh environments.
XLVS11620121 carries IECEx/ATEX certification alongside NEC/CEC, confirming compliance across international hazardous-location standards. The IP66/NEMA 4X ratings ensure robust protection against dust and water ingress, enabling safe operation in Zone 1/2 and other hazardous classifications. This combination reduces regulatory risk and simplifies procurement for global projects.
Yes. The Ex-CELL design supports standard components and mating hardware used with Crouse-Hinds stainless enclosures. With 316L stainless steel construction, one gland plate, and vertical lugs, you can source compatible hinges, seals, and gland kits from Eaton’s catalog to maintain sealing integrity and serviceability without custom modifications.
The 316L stainless steel construction provides superior corrosion resistance, reducing repainting and structural degradation in aggressive environments. Routine maintenance focuses on seal integrity, gland plate access, and lid alignment. The enclosure’s rugged build minimizes unplanned downtime, extends product life in offshore or chemical processing settings, and lowers total cost of ownership over the asset lifecycle.
By combining IP66/NEMA 4X protection with IECEx/ATEX and NEC/CEC certifications, this enclosure minimizes compliance hurdles and maintenance costs while reducing downtime from contamination or corrosion. Its stainless-steel construction and compact 16x20x12 footprint speed up installation and retrofits, delivering a faster path to regulatory approval and a favorable return on investment in hazardous-area projects.