Eaton Crouse-Hinds Ex-CELL XLVS12416060 - IP66

Part Number: XLVS12416060
Manufacturer
Eaton Crouse-Hinds
Part number
XLVS12416060

Quick Summary

The Eaton Crouse-Hinds Ex-CELL XLVS12416060 enclosure protects electrical and control gear in hazardous, industrial environments. Providing reliable protection reduces downtime and simplifies maintenance in facilities operating in Class I, Zone 1 or Division 2 locations. This enclosure carries IECEx/ATEX and NEC/CEC certifications, plus a NEMA 4X rating and IP66 ingress protection, helping ensure compliance and safe operation across harsh conditions. Constructed from 316L stainless steel, it resists corrosion in washdown and chemical environments, supporting long service life and lower total cost of ownership. With dimensions 24" x 16" x 6" and vertical-lug mounting, it enables straightforward deployment in control rooms and field installations, even in space-constrained areas.

Product Information

Extended Description

XLVS12416060 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 24" x 16" x 6", 316L stainless steel, 0 gland plates, Vertical lugs
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLVS12416060
UPC
662276748811
Product Length/Depth
16 in
Product Height
24 in
Product Width
6 in
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX NEC/CEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class II, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
24" x 16" x 6"
Number of gland plates
0
Type
Vertical lugs
Hazardous-location compliance reduces regulatory risk and enables installation in Zone 1/Class I environments, delivering safer operations and faster project approvals. The Ex-CELL series is engineered from 316L stainless steel for superior corrosion resistance, extending service life in washdown and chemical processes while lowering replacement costs. IP66 and NEMA 4X protection translate to reliable ingress protection against dust and water, minimizing unplanned downtime in offshore, mining, and chemical plants. The enclosure’s 24" x 16" x 6" footprint plus vertical-lug mounting simplifies field retrofits and new installs, reducing labor time and enabling plug-and-play compatibility with existing frames and components. Zero gland plates (0 gland plates) offer a clean foundation for customized gland configurations when needed, supporting flexible cable management. Global certifications (IECEx/ATEX, NEC/CEC) enable cross-border deployments with confidence. Overall lifecycle cost is improved through robust stainless steel durability and consistent performance across harsh environments.

Get a Quick Quote for a Eaton Crouse-Hinds XLVS12416060

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLVS12416060? Enquire Now

FAQs

To install XLVS12416060 in hazardous locations, mount the enclosure using its vertical lugs, ensure proper surface preparation, and connect field wiring through approved glands if required. The 316L stainless steel construction and IP66/NEMA 4X rating provide robust protection against dust, water, and corrosion, while IECEx/ATEX and NEC/CEC certifications confirm compliance for Class I/Zone 1 installations. Follow Eaton installation instructions ENK10673 for step-by-step guidance and safety considerations.
Key specifications include a 24" x 16" x 6" enclosure size, 316L stainless steel material, 0 gland plates, vertical lugs, IP66 ingress protection, and NEMA 4X rating. Cataloged as XLVS12416060, it carries IECEx/ATEX and NEC/CEC certifications for hazardous locations, with a UPC of 662276748811. This combination supports durable, compliant deployments in harsh environments.
Yes. The Ex-CELL XLVS12416060 is designed for hazardous locations such as Class I/Zone 1, with IECEx/ATEX and NEC/CEC certifications, IP66 protection, and corrosion-resistant 316L stainless steel. Its dimensions and vertical-lug mounting make it adaptable for space-constrained offshore platforms and chemical plants, while the 4X/NEMA protection reduces maintenance needs and extends service life in aggressive environments.
XLVS12416060 carries IECEx/ATEX, NEC/CEC, NEMA 4X, and IP66 certifications, all of which validate safe operation in hazardous and classified locations. These certifications facilitate global deployment, ensure compliance with industry standards, and reduce project risk by confirming the enclosure’s suitability for demanding environments such as oil and gas, chemical processing, and mining.
The 316L stainless steel composition provides excellent corrosion resistance, extending service life in washdown and chemically aggressive settings. With IP66/NEMA 4X protection and rigorous certifications, maintenance needs are reduced due to fewer protective breaches. The enclosure also supports straightforward installation and long-term reliability, contributing to lower total cost of ownership and higher asset uptime in demanding facilities.