Eaton XLVS12424121 Ex-CELL Enclosure - IP66, 4X
Part Number: XLVS12424121
Manufacturer
Eaton Crouse-Hinds
Part number
XLVS12424121
Quick Summary
The Eaton Ex-CELL enclosure protects electrical equipment in hazardous locations with a robust 316L stainless steel housing. Maintenance downtime from corrosion and ingress is a top cost driver in hazardous plants. It meets NEC/CEC IECEx/ATEX, IP66, and NEMA 4X ratings, enabling safe operation in classified areas. Designed for hazardous locations, stainless steel enclosures from the Ex-CELL line help ensure regulatory compliance and uptime. This combination supports asset protection, faster installation, and lower total cost of ownership across industrial facilities. Its gland plate option and vertical lugs streamline field wiring while maintaining ingress protection. This translates to reduced commissioning time and predictable performance in harsh environments. Rugged 24x24x12 in footprint fits many stainless steel enclosure applications across process, mining, and energy sectors.
Product Information
Extended Description
XLVS12424121 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 24" x 24" x 12", 316L stainless steel, 1 gland plate, Vertical lugs
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLVS12424121
Product Length/Depth
24 in
Product Height
24 in
Product Width
12 in
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IECEx/ATEX
NEC hazardous rating
Class I, Zone 1 Class II, Division 2 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
24" x 24" x 12"
Number of gland plates
1
Type
Vertical lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
ENK10673 Ex-Cell Operating Instructions
Eaton Specification Sheet - XLVS12424121
316L stainless steel construction delivers exceptional corrosion resistance and long service life in chemical, offshore, and heavy industrial environments. This reduces maintenance intervals and unplanned downtime, lowering lifecycle costs for critical equipment. It is ideally suited for hazardous locations such as chemical plants and refineries where exposure to aggressive media is routine. IP66 and NEMA 4X protection provide robust ingress resistance against dust, high-pressure washdowns, and harsh washdowns encountered in harsh facilities. The result is enhanced safety, regulatory confidence, and reduced risk of damp or contaminated controls in demanding facilities. This protection supports reliable operation of control panels, drives, and power distribution in hazardous locations. With a 24x24x12 inch footprint, a single gland plate, and vertical lugs, installation and wiring are remarkably streamlined and predictable. Field wiring is easier, commissioning time is shortened, and mounting is straightforward in constrained or retrofit environments. The compact footprint also facilitates modular expansions and retrofits within existing control rooms without compromising safety or access. NEC/CEC compliance and IECEx/ATEX certifications enable scalable deployments across global facilities with consistent safety baselines. The area classification of Hazardous/Classified Locations, together with IP66 and NEMA 4X ratings, helps ensure code conformity and risk mitigation. These approvals reduce project risk, accelerate time-to-operation for multi-site installations, and simplify supplier qualification for end users. Designed to integrate with the Ex-CELL family of enclosures and mounting accessories, XLVS12424121 supports flexible configurations and future upgrades. The material, finish, and protection work in concert to lower maintenance costs, spare parts requirements, and replacement cycles over the system life. This broad compatibility translates into lower total cost of ownership and faster ROI for industrial automation projects.
Get a Quick Quote for a Eaton Crouse-Hinds XLVS12424121
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLVS12424121?
Enquire Now
FAQs
XLVS12424121 includes a single gland plate and vertical lugs to simplify field wiring and mounting. The 24x24x12 in footprint fits common control cabinets, while the 316L stainless steel construction delivers long-term corrosion resistance. This combination supports scalable, reliable installations in hazardous locations without requiring specialized accessories.
The enclosure is rated IP66 and NEMA 4X, providing strong protection against dust, moisture, and washdowns in demanding environments. It supports hazardous-location classifications including NEC/CEC Class I, Zone 1 and Class II, Division 2, enabling safe operation in regulated facilities such as chemical plants and refineries.
Yes. The Ex-CELL enclosure aligns with NEC/CEC and IECEx/ATEX standards, plus area classifications for Hazardous/Classified Locations. This global compliance enables deployments across multi-site operations with consistent safety baselines, reducing design risk and accelerating project approval in international markets.
The combination of a single gland plate, vertical lugs, and a compact footprint streamlines wiring and mounting, shortening commissioning times and minimizing access constraints during retrofit projects. Its compatibility with Ex-CELL accessories supports scalable configurations and easier upgrades without extensive redesign or equipment replacement.
316L stainless steel provides superior corrosion resistance, reducing maintenance and part replacements in harsh environments. With IP66 and NEMA 4X protection, the risk of ingress-related faults drops, leading to lower downtime. Global certifications further reduce qualification costs and enable faster ROI for process automation projects.