Eaton Crouse-Hinds Ex-CELL XLVS22016080 Enclosure - IP66
Part Number: XLVS22016080
Manufacturer
Eaton Crouse-Hinds
Part number
XLVS22016080
Quick Summary
The Eaton Crouse-Hinds Ex-CELL XLVS22016080 enclosure provides rugged protection for electrical equipment in hazardous locations. Operators often struggle with corrosion, ingress, and regulatory complexity when assets sit in demanding environments. This enclosure carries IECEx/ATEX and NEC/CEC certifications, along with IP66 and NEMA 4X ratings, to help you meet global compliance. With a stainless-steel body and a compact 20x16x8 in footprint, it supports easy mounting and long-term reliability, reducing maintenance costs while enabling safe, compliant installations. The vertical lugs and zero gland plates simplify installation in tight spaces, while the Ex-CELL family’s proven durability translates to less downtime and more productive uptime for your critical processes.
Product Information
Extended Description
XLVS22016080 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 20" x 16" x 8", 304 stainless steel, 0 gland plates, Vertical lugs
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLVS22016080
UPC
662276748385
Product Length/Depth
16 in
Product Height
20 in
Product Width
8 in
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX NEC/CEC
NEC hazardous rating
Class II, Division 2 Class I, Zone 1 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
304 stainless steel
Enclosure size
20" x 16" x 8"
Number of gland plates
0
Type
Vertical lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
ENK10673 Ex-Cell Operating Instructions
Eaton Specification Sheet - XLVS22016080
Feature: 304 stainless steel construction delivers outstanding corrosion resistance and mechanical durability. Business Impact: This reduces replacement frequency and maintenance costs in chemical processing, oil and gas, and offshore environments. Application: Long service life in demanding environments with minimal rework during retrofits. Feature: IP66 ingress protection and NEMA 4X rating. Business Impact: Protects against dust, water jets, and harsh weather, boosting reliability and uptime. Application: Outdoor or washdown areas, skid-mounted or fixed systems in chemical plants. Feature: IECEx/ATEX and NEC/CEC certifications. Business Impact: Enables global deployment and regulatory compliance, lowering project risk and approval times. Application: Hazardous locations across multiple regions with strict safety standards. Feature: Enclosure size 20" x 16" x 8" with vertical lugs and 0 gland plates. Business Impact: Facilitates straightforward wiring, mounting flexibility, and reduced ingress points, accelerating installation. Application: Control panels in space-constrained areas and retrofit projects. Feature: Vertical lugs mounting compatibility and exposed interior that supports straightforward conduit routing. Business Impact: Faster installation and serviceability, lower labor costs, and safer access for maintenance staff. Application: Industrial control panels in hazardous environments requiring robust, configurable mounting.
Get a Quick Quote for a Eaton Crouse-Hinds XLVS22016080
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLVS22016080?
Enquire Now
FAQs
XLVS22016080 provides vertical lugs for versatile mounting on flat surfaces or panels. The enclosure’s 20x16x8 in footprint fits common control arrangements in hazardous zones, and the vertical lugs allow secure, vibration-resistant mounting without requiring special brackets. For retrofit projects, verify whether existing mounting plates align with the Ex-CELL dimensions and ensure appropriate conduit entry clearance.
This Ex-CELL enclosure carries IECEx/ATEX and NEC/CEC standards, with NEC hazardous ratings including Class I, Zone 1 and Division 2, along with Class II, Division 2. It also meets NEMA 4X and IP66 requirements, providing ingress protection against water, dust, and corrosive exposures. These certifications facilitate global deployment and reduce compliance risk for hazardous location deployments.
Yes. The combination of IP66 and NEMA 4X ratings, plus 304 stainless steel construction, makes XLVS22016080 well-suited for oil and gas, chemical processing, and downstream/rigsite applications. Its corrosion resistance, robust sealing, and ability to withstand washdowns help protect sensitive controls and drive longer asset life in tough environments.
The enclosure is certified to IECEx/ATEX for explosion-protected environments and NEC/CEC for hazardous-location compliance. These standards verify safe enclosure operation in Zone 1 and Division 2 areas, ensuring that internal components remain isolated from ignition sources and that assembly practices meet rigorous safety criteria across international markets.
Maintenance is typically reduced due to the corrosion resistance and sealed design, which minimizes ingress and related downtime. The stainless steel construction withstands harsh environments, lowering replacement costs and service intervals. ROI benefits include longer service life, fewer spare parts, and improved overall equipment availability in demanding industrial settings.