Eaton 100MCSR6313MW AutoVAR capacitor bank - UL 508A

Part Number: 100MCSR6313MW
Manufacturer
Eaton
Part number
100MCSR6313MW

Quick Summary

The Eaton LV AutoVAR 300 capacitor bank improves power factor for medium to large motors and drives. Many users struggle with reactive power penalties and uptime costs when not tuned for peak loads. This unit carries UL 508A, CSA C22.2 No. 190, UL 810 and IEEE 18 certifications, delivering safety and reliability. Its wall-mount footprint with dimensions 14 in D x 60 in H x 36 in W and a 280 lb weight supports straightforward retrofits while reducing installation time. Its 600 V rating supports broad compatibility with industrial drives and energy management systems, delivering measurable returns through improved efficiency, reduced peak demand, and predictable maintenance planning.

Product Information

Extended Description

100MCSR6313MW Eaton: Eaton wall mtd, switched cap bank, 600V, 100 kvar 250 cb and 3R
Product Name
Eaton LV AutoVAR 300 capacitor bank
Catalog Number
100MCSR6313MW
UPC
786685198934
Product Length/Depth
14 in
Product Height
60 in
Product Width
36 in
Product Weight
280 lb
Certifications
UL 508A CSA Std. C22.2 No. 190 UL 810 IEEE Std. 18
Type
AutoVAR
Phase
Three-phase
Is a three-phase AutoVAR switched capacitor bank rated for 600 V and delivering 100 kvar reactive power. Business impact: provides targeted reactive power correction that lowers energy costs, reduces utility penalties, and stabilizes voltage across load fluctuations. Application: ideal for motor drives, fans, pumps, and process equipment in manufacturing and facilities where consistent PF is critical.\n\nIs a compact wall-mount enclosure with a footprint of 14 in D by 60 in H by 36 in W and a 280 lb weight. Business impact: enables space-efficient retrofits and simplified integration into existing control panels, shortening installation times and minimizing structural changes. Application: suitable for retrofit projects in mid to large facilities and energy management cabinets.\n\nIs certified to UL 508A, CSA Std C22.2 No. 190, UL 810 and IEEE Std 18. Business impact: regulatory compliance and safety reduce approval cycles and risk for panel builders and end users. Application: critical in industrial automation environments where code compliance across jurisdictions is mandatory.\n\nIs designed for three-phase operation in 600 V networks. Business impact: seamless integration with standard industrial drives and buses, supporting wide operating ranges and scalable energy management. Application: ideal for facilities with mixed load profiles seeking PF stability during peak demand.\n\nIs compatible with the Eaton AutoVAR ecosystem and supports straightforward installation. Business impact: simplifies commissioning, maintenance planning, and future expansion while delivering predictable performance. Application: suitable for new builds and retrofits in manufacturing, HVAC, and process industries seeking measurable efficiency gains.

Get a Quick Quote for a Eaton 100MCSR6313MW

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 100MCSR6313MW? Enquire Now

FAQs

Plan for a clean, ventilated wall-mount area with adequate clearance per enclosure ratings. Mount the unit in a three-phase panel, connect incoming 600 V three-phase supply to the appropriate switching contactors, and wire the capacitor modules according to the Eaton specification. Ensure proper grounding, labeling, and protective devices, then verify compliance with UL 508A and IEEE 18 guidelines.
The unit is UL 508A, CSA Std C22.2 No. 190, UL 810, and IEEE Std 18 certified. These certifications confirm safe operation in control panels and industrial environments, streamline panel approvals, and reduce regulatory risk. They are typically required by NEC-based codes and regional standards, making this capacitor bank a dependable fit for compliant installations.
Yes. The capacitor bank is designed for 600 V operation in a three-phase configuration and provides 100 kvar of reactive power, enabling effective power factor correction for motor drives, pumps, and process equipment. It supports PF improvement across mixed-load scenarios, helping to stabilize voltage and reduce energy waste.
Schedule periodic visual inspections for signs of overheating, swelling, or loose connections. Verify wiring integrity and protection devices during each preventive maintenance window. Keep the enclosure clean and dry, confirm grounding continuity, and reassess PF targets as load profiles shift. Routine checks help extend capacitor life and maintain consistent performance.
By correcting reactive power and lowering utility penalties, the AutoVAR bank delivers measurable energy cost reductions and improved voltage stability. ROI depends on the facility's load profile and peak demand; facilities with significant motor and drive loads typically see faster payback through lower kVA demand charges and reduced energy waste.