Eaton 12191031003 Ex-Lite N Exit Sign - IP66 IECEx/ATEX

Part Number: 12191031003
Manufacturer
Eaton
Part number
12191031003

Quick Summary

Eaton 12191031003 Ex-Lite N exit sign is a hazardous-location LED exit sign designed for reliable egress in Zone 1/21/22 environments. It features 422 mm length, 230 mm width, and 115 mm height aluminum housing with a gray finish and wall-mount capability. It operates on 110-277 Vac or 110-250 Vdc at 50/60 Hz with LED illumination for long life. Certifications include IECEx/ATEX and IP66, with Zone 1/21/22 approvals that support regulatory compliance. The self-contained battery, pictogram cover (arrow 6h), and M25 glands simplify installation and outage operation. This DIN 4844-compatible sign is suitable for retrofits and new builds in oil, gas, chemical, and mining facilities, delivering safety and reliability.

Product Information

Extended Description

12191031003 Eaton: Eaton Crouse-Hinds series Ex-Lite N exit sign, Arrow down, Gray, LED, White letters, Aluminum alloy, Wall mount, Cover with pictogram (arrow 6h), battery, 1 x M25 plastic cable glands, 1 x M25 screw plug, DIN 4844, 110-277 Vac, 110-250 Vdc
Product Name
Eaton's Crouse-Hinds series Ex-Lite N exit sign
Catalog Number
12191031003
EAN
4250217412714
Product Length/Depth
422 mm
Product Height
115 mm
Product Width
230 mm
Product Weight
6.7 kg
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX IEC
IECEx/ATEX hazardous rating
Zone 1 Zone 21 Zone 22 Zone 2
Ingress protection (IP) ratings
IP66
Lamp type
LED
Exit sign designation
Arrowhead downwards
Letter color
White
Trade size
1 x M25 plastic cable glands, 1 x M25 screw plug
Voltage rating
110-277 Vac, 110-250 Vdc
Frequency rating
50/60 Hz
Mounting
Wall
Material
Aluminum alloy
Housing finish color
Gray
Special features
Includes cover with pictogram (arrow 6h), self-contained battery system
Type
DIN 4844
Feature: LED lighting for the Ex-Lite N exit sign delivers bright, long-life illumination with minimal lumen depreciation in harsh environments. Business impact: predictable performance lowers maintenance costs, reduces lamp replacements, and sustains evacuation visibility through extended duty cycles. Application: ideal for hazardous-area egress in oil, gas, chemical, and mining facilities where uptime and visibility are non-negotiable. Feature: Self-contained battery system and pictogram cover (arrow 6h) support standalone operation during power loss. Business impact: ensures exit signaling remains active during outages, boosting safety and compliance with emergency lighting requirements. Application: mission-critical signaling in zones with variable power availability or where continuous emergency illumination is mandated. Feature: IP66 ingress protection and a rugged aluminum housing with a gray finish. Business impact: resists dust, water jets, and washdowns, reducing field failures and warranty claims. Application: outdoor walls, dock areas, chemical plants, and other harsh industrial locations. Feature: Wide voltage and frequency range—110-277 Vac and 110-250 Vdc at 50/60 Hz—simplifies electrical design and regional deployment. Business impact: simplifies procurement, lowers on-site wiring errors, and supports standardized training and maintenance across global sites. Application: multinational facilities and projects spanning diverse power networks and regional standards. Feature: Wall mounting with DIN 4844 compatibility, plus 1 x M25 plastic cable gland and 1 x M25 screw plug, streamlines installation. Business impact: reduces pre-wiring, accelerates commissioning, and minimizes change orders in retrofit or greenfield hazardous-area projects. Application: new builds or retrofits in hazardous locations requiring compliant, fast-to-install exit signage.

Get a Quick Quote for a Eaton 12191031003

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 12191031003? Enquire Now

FAQs

The Ex-Lite N is IECEx/ATEX certified for hazardous locations, with Zone 1 and Zone 21/22 approvals, plus IP66 ingress protection. It meets DIN 4844 standards for signage and is suitable for compliant installation in hazardous environments found in petrochemical, mining, and other high-risk facilities.
Model 12191031003 supports a wide input range: 110-277 Vac and 110-250 Vdc, operating at 50/60 Hz. This flexibility simplifies global deployment and ensures consistent performance across regional electrical systems.
Yes. The Ex-Lite N is certified for Zone 1 and related hazardous locations (Zone 21/22) under IECEx/ATEX, providing reliable egress indication in explosive atmospheres while maintaining IP66 protection against dust and water ingress.
It includes a wall-mount design, DIN 4844 compatibility, and 1 x M25 plastic cable glands plus 1 x M25 screw plug. A self-contained battery and pictogram cover (arrow 6h) further simplify wiring, commissioning, and maintenance, reducing site work and downtime.
LED illumination offers long life with low lumen depreciation, reducing replacement frequency. The self-contained battery ensures operation during outages, lowering maintenance intervals and improving safety compliance in mission-critical facilities.