Eaton 12191031101 Ex-Lite N Exit Sign - IP66 Hazardous

Part Number: 12191031101
Manufacturer
Eaton
Part number
12191031101

Quick Summary

Ex-Lite N exit sign is a wall-mounted LED emergency sign that delivers reliable visibility for hazardous locations. In demanding environments, outages or dim lighting can compromise safety; this unit is designed to endure harsh conditions while maintaining legibility of the pictogram. With IECEx/ATEX certification across Zones 1, 2, 21, and 22 and IP66 ingress protection, it meets rigorous global standards. The combination of rugged construction and a self-contained battery reduces maintenance cycles, while universal voltage compatibility supports a range of power systems. For facilities seeking reliable hazardous-area signaling, this sign delivers safety, compliance, and long-term cost efficiency.

Product Information

Extended Description

12191031101 Eaton: Eaton Crouse-Hinds series Ex-Lite N exit sign, Arrowhead right, Gray, LED, White letter color, Aluminum alloy, Wall mount, Cover with pictogram (arrow 3h), battery, 2 x M20 metal thread, DIN 4844, 110-277 Vac, 110-250 Vdc
Product Name
Eaton's Crouse-Hinds series Ex-Lite N exit sign
Catalog Number
12191031101
EAN
4250217412691
Product Length/Depth
422 mm
Product Height
115 mm
Product Width
230 mm
Product Weight
6.7 kg
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX
IECEx/ATEX hazardous rating
Zone 22 Zone 2 Zone 21 Zone 1
Ingress protection (IP) ratings
IP66
Lamp type
LED
Exit sign designation
Arrowhead right
Letter color
White
Trade size
2 x M20 metal thread
Voltage rating
110-277 Vac, 110-250 Vdc
Frequency rating
50/60 Hz
Mounting
Wall
Material
Aluminum alloy
Housing finish color
Gray
Special features
Includes cover with pictogram (arrow 3h), self-contained battery system
Type
DIN 4844
Feature LED illumination and an aluminum alloy housing deliver energy efficiency and corrosion resistance, which translates to lower operating costs and less downtime in hazardous environments. Business impact is reduced energy use and longer service life, supporting continuous egress illumination in chemical plants, oil rigs, refineries, and mining operations. Application: deploy in wall-mounted configurations where space is constrained and critical escape paths require consistent visibility. Feature IP66 protection and IECEx/ATEX certifications safeguard operation in dust, water, and explosive atmospheres; the result is compliant performance with fewer field failures. Application: installation in Zone 1/2 and Zone 21/22 locations with heavy-duty dust and moisture. Feature Self-contained battery with pictogram cover enables stand-alone operation during mains outages; benefit is uninterrupted egress signaling without external power dependencies; application includes retrofit or new builds. Feature 110-277 VAC and 110-250 VDC compatibility offers flexible supply options; impact is easier integration, less wiring complexity, and cost savings during site upgrades. Feature Wall mounting with DIN 4844 footprint and 2 x M20 threads simplifies installation and future maintenance; application spans chemical plants, offshore platforms, and manufacturing floors. Long-tail keywords: hazardous area exit sign, LED exit sign for ATEX zones, IP66 exit sign, wall-mounted hazardous location lighting, DIN 4844 exit sign, offshore lighting.

Get a Quick Quote for a Eaton 12191031101

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 12191031101? Enquire Now

FAQs

When installing the Ex-Lite N, ensure a wall-mounted DIN 4844 footprint with 2 x M20 entries and unobstructed pictogram visibility. Verify IP66 seals, secure cable entries, and follow local ATEX/IECEx installation standards. Plan for proper grounding, adequate clearance for maintenance, and compatibility with the 110-277 VAC or 110-250 VDC supply.
Model 12191031101 operates from 110-277 VAC or 110-250 VDC, with a 50/60 Hz frequency. It uses LED illumination, includes a self-contained battery, and measures 422 mm by 230 mm by 115 mm with a mass around 6.7 kg. It supports a wall-mount DIN 4844 configuration and features two M20 metallic thread entries for wiring.
Yes. The Ex-Lite N is IECEx/ATEX certified for hazardous areas and is rated for Zone 1, Zone 2 as well as Zone 21 and Zone 22. It carries IP66 protection, ensuring robust ingress resistance against dust and water. This makes it suitable for chemical plants, oil refineries, and other hazardous-location installations.
Retrofits are straightforward thanks to the wall-mount DIN 4844 footprint and 2 x M20 threads. Ensure compatible power supply within 110-277 VAC or 110-250 VDC, verify IP66 seals after mounting, and use the pictogram cover for clear egress indicators. The self-contained battery minimizes downtime during power interruptions.
The LED design and self-contained battery reduce maintenance frequency, while the robust build and IP66/IPEx ratings minimize replacement and service calls in harsh environments. Although upfront cost is higher, lifecycle costs are lower due to longer LED life, fewer lumen drops, and reduced downtime from failed exit signaling.