Eaton 12191130005 Exit Sign - Ex-Lite ZE IP66

Part Number: 12191130005
Manufacturer
Eaton
Part number
12191130005

Quick Summary

Exit Sign functionality from Eaton Ex-Lite ZE provides reliable egress visibility in hazardous industrial environments. Facility teams often wrestle with maintenance, self-test routines, and documentation to prove compliance for emergency lighting. This Ex-Lite ZE supports IP66 ingress protection and NEC/CEC standards, with Hazardous Locations ratings that cover Class I Division 2 and Zone 1. Its LED illumination, wall-mounting ease, and self-diagnostic features simplify installation and ongoing maintenance, delivering dependable life-safety messaging while reducing total cost of ownership. The unit also operates across 50/60 Hz and accepts wide voltage inputs from 120-277 Vac or 110-250 Vdc, making it compatible with retrofit and new-build projects.

Product Information

Extended Description

12191130005 Eaton: Eaton Crouse-Hinds series Ex-Lite ZE exit sign, 3/4" entries, 50/60 Hz, LED, Red letter color, Horizontal lettering, Aluminum alloy, Wall mount, With nickel cadmium battery, self-diagnostic, self-test, 120-277 Vac, 110-250 Vdc
Product Name
Eaton Crouse-Hinds series Ex-Lite ZE exit sign
Catalog Number
12191130005
EAN
4250959900630
Product Length/Depth
16.6 in
Product Height
9.1 in
Product Width
4.5 in
Product Weight
14.75 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 1 Class II, Division 2
Ingress protection (IP) ratings
IP66
Lamp type
LED
Letter color
Red
Lettering direction
Horizontal
Voltage rating
120-277 Vac, 110-250 Vdc
Frequency rating
50/60 Hz
Mounting
Wall
Entry size
3/4"
Material
Aluminum alloy
Special features
With nickel cadmium battery, self-test
LED illumination with a nickel cadmium battery delivers bright, low-energy exit signaling for fast, reliable egress during an outage. This combination reduces energy costs and provides a robust back-up source, helping plant managers meet life-safety obligations without compromising uptime in hazardous environments such as chemical processing or oil and gas facilities. Self-diagnostic and self-test features offer proactive maintenance and clear compliance evidence. The ability to automatically verify operation reduces unplanned outages and streamlines audits, which is especially valuable in environments with rigorous regulatory oversight. Wide power compatibility supports both ac and dc inputs: 120-277 Vac and 110-250 Vdc at 50/60 Hz. This flexibility simplifies procurement during retrofits and new installations, reducing the need for multiple stock keeping units. In practice, it allows a single, standardized exit sign across diverse electrical systems, cutting installation time. Durable housing uses aluminum alloy and IP66 protection, resisting dust, water, and harsh washdown conditions. This rugged construction ensures reliable operation in Class I Division 2, Zone 1, and Class II Division 2 areas, where equipment must withstand corrosive atmospheres and vibrations. In field tests, it demonstrates consistent performance in extreme temperatures and demanding industrial cycles. Compact wall-mount design with 3/4" entries and a 16.6 in length, 9.1 in height, and 4.5 in width keeps installation tidy and accessible. The lightweight 14.75 lb unit supports quick retrofits and reduces crane time on site. Together with horizontal red lettering and LED technology, it delivers legible, compliant messaging across long egress paths.

Get a Quick Quote for a Eaton 12191130005

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 12191130005? Enquire Now

FAQs

Install on a wall using the 3/4" entries with compatible wiring. The unit supports 120-277 Vac or 110-250 Vdc at 50/60 Hz and includes a nickel cadmium battery for backup. Use the IF 479 installation guidelines and ensure proper mounting to maintain IP66 integrity in Class I Division 2, Zone 1 or Class II Division 2 environments.
Key specs include LED lamp type with red horizontal lettering, voltage range 120-277 Vac and 110-250 Vdc, 50/60 Hz operation, IP66 ingress protection, 3/4" entry size, aluminum alloy housing, wall mounting, and a backup nickel cadmium battery. The unit weighs 14.75 lb and uses 16.6 in by 9.1 in by 4.5 in dimensions, optimizing space in tight installations.
Yes. The Ex-Lite ZE is designed for Hazardous/Classified Locations with NEC/CEC compliance and IP66 protection. It is rated for Class I Division 2 and Zone 1, as well as Class II Division 2, making it appropriate for chemical plants, refineries, and other hazardous areas requiring robust, code-compliant exit signaling.
The product adheres to NEC/CEC standards and hazardous location ratings, with IP66 protection. Documentation includes the Ex-Lite catalog page, installation instructions (IF 479), and the Eaton specification sheet for model 12191130005, enabling traceable compliance, easy procurement, and consistent field installation across sites.
Self-test and self-diagnostic features simplify ongoing maintenance by continuously verifying operation and generating actionable status signals, reducing downtime during audits. The nickel cadmium battery provides reliable backup, improving life-safety reliability and lowering total cost of ownership through fewer service visits and predictable performance in power outages.