Eaton LV AutoVAR 300 capacitor bank - UL 508A

Part Number: 150MCSR6313
Manufacturer
Eaton
Part number
150MCSR6313

Quick Summary

Eaton LV AutoVAR 300 capacitor bank improves power factor for 600 V, three-phase industrial systems. Poor power factor often leads to higher energy costs, utility penalties, and unnecessary heat in electrical networks. This solution complies with IEEE Std. 18, CSA Std. C22.2 No. 190, and UL 508A, delivering safety and reliability in switchgear assemblies. Designed for wall-mounted installations, it provides 150 kVAR of correction capabilities in a compact footprint, supporting scalable deployment across growing facilities. By delivering consistent PF improvement, facilities can reduce demand charges and achieve stable voltage profiles, driving measurable business value in energy spend and equipment longevity.

Product Information

Extended Description

150MCSR6313 Eaton: Eaton Wall-mounted switched capacitor bank, Low voltage application, 150 kVAR, 600V, 144A, Three-phase, 60 Hz
Product Name
Eaton LV AutoVAR 300 capacitor bank
Catalog Number
150MCSR6313
UPC
786685879307
Product Length/Depth
36 in
Product Height
60 in
Product Width
13.67 in
Product Weight
240 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the product or eighteen (18) months from the date of shipment of the product, whichever occurs first. Plus 5 years on capacitor cells.
Certifications
IEEE Std. 18 CSA Std. C22.2 No. 190 UL 508A UL 810
Type
Low voltage application
Amperage Rating
144A
Frequency rating
60 Hz
Phase
Three-phase
Voltage rating
600 V
kVA rating
150 KVR
Feature: 150 kVAR capacity with 600 V, 144 A, three-phase, 60 Hz operation. Business Impact: Rapid, predictable reactive power support reduces wasted energy and lowers utility demand charges. Application: Suitable for mid- to large-size manufacturing lines and facilities with motor-heavy loads. The system maintains consistent power factor under varying load conditions, improving overall efficiency and grid interaction.Feature: Wall-mounted switched capacitor bank. Business Impact: Space-efficient installation with simplified maintenance and faster retrofits. Application: Ideal for retrofit projects inside existing switchgear enclosures or compact facilities where floor space is at a premium. This design minimizes installation time and reduces site disruption.Feature: Robust safety and certifications (IEEE Std. 18; CSA Std. C22.2 No. 190; UL 508A; UL 810). Business Impact: Regulatory compliance and safer operation lessen risk while easing procurement and long-term asset management. Application: Critical for industries with strict safety and performance requirements such as process industries and commercial facilities.Feature: One-year warranty with an additional five years on capacitor cells. Business Impact: Lower total cost of ownership through extended capacitor cell life and predictable maintenance planning. Application: Asset-intensive environments benefit from reduced replacement cycles and clearer budgeting for capacitor health.Feature: Compatibility with low-voltage power systems and 60 Hz networks. Business Impact: Smooth integration with existing 600 V panel boards and Eaton AutoVAR ecosystem, enabling scalable expansion without rewiring. Application: Common in automotive, metals, and general manufacturing facilities where PF correction is needed across multiple lines.

Get a Quick Quote for a Eaton 150MCSR6313

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 150MCSR6313? Enquire Now

FAQs

Plan for a wall-mounted installation within a compliant enclosure rated for 600 V service. Ensure adequate clearance for cooling and inspection, proper wiring to the 144 A bus, and secure mounting to support weight (approximately 240 lb). Verify panel compatibility with a 60 Hz system and follow UL 508A wiring practices. Pre-check peaking loads to optimize kVAR sizing and avoid over/under-correction in the initial commissioning.
This unit delivers 150 kVAR of reactive power at 600 V, three-phase, 60 Hz. By supplying reactive current locally, it raises the overall power factor toward unity, reducing VAR flow from the grid, lowering energy losses, and decreasing utility penalties. Correct sizing and staged cross-tiring with your load profile ensure stable PF improvements during peak and off-peak periods.
Yes. The 150 kVAR LV AutoVAR is well-suited for motor-driven processes common in metals, automotive, and general manufacturing, as well as processing environments where consistent PF correction improves motor efficiency and minimizes heat. The wall-mounted design supports integration into existing switchgear, helping retrofit projects in facilities with space constraints and strict safety requirements.
It meets IEEE Std. 18, CSA Std. C22.2 No. 190, UL 508A, and UL 810. Certification assures electrical safety, conductor protection, and electrical equipment reliability, which is essential for ongoing plant safety audits, insurance compliance, and long-term maintenance planning in industrial facilities.
Expect routine inspections on capacitor cells, with a 5-year life expectancy on cells and a 1-year base warranty. ROI comes from reduced energy costs and demand charges, improved voltage stability, and extended equipment life. For asset-intensive operations, plan a quarterly health review and a yearly PF audit to maximize uptime and financial returns.