Eaton 1800MV3AI41FGMW Capacitor Bank - CSA Certified

Part Number: 1800MV3AI41FGMW
Manufacturer
Eaton
Part number
1800MV3AI41FGMW

Quick Summary

Eaton 1800MV3AI41FGMW Capacitor Bank is an automatically switched MV AutoVAR solution designed for reactive power management in medium-voltage systems. Operators often battle VAR fluctuations, delayed switching, and penalties from utilities when reactive power is poorly managed. CSA Certified (Canada Only) compliance ensures safety and traceability across Canadian sites, while the 4160V, 60 Hz rating aligns with standard MV power systems. This solution helps substations and industrial facilities meet grid codes while delivering cost savings through better power factor and reduced demand charges. Designed for large facilities and substations, it supports scalable, automated VAR control for efficient energy management. Its CSA-certified design and 4160V, 60 Hz rating align with typical industrial power systems, easing procurement and installation.

Product Information

Extended Description

1800MV3AI41FGMW Eaton: Eaton Automatically Switched MV AutoVAR Capacitor Bank, 1800KVAR, 4160V, 60Hz, Unfiltered
Product Name
Eaton MV AutoVAR unfiltered capacitor bank
Catalog Number
1800MV3AI41FGMW
UPC
786689014599
Product Length/Depth
49 in
Product Height
91 in
Product Width
135 in
Product Weight
6500 lb
Certifications
CSA Certified (Canada Only)
Type
Capacitor bank
Frequency rating
60 Hz
Feature: Automatically Switched MV AutoVAR capacitor bank. Business Impact: Reduces reactive power penalties and improves voltage stability, enabling smoother operation of sensitive equipment. Application: Substations and industrial facilities needing reliable VAR control. Feature: High capacity of 1800 kVAR at 4160V 60 Hz. Business Impact: Scales to heavy reactive loads, supporting tighter power factor targets and grid code compliance. Application: Large manufacturing sites and utility-connected systems. Feature: Unfiltered capacitor bank design. Business Impact: Cost-effective solution for sites where harmonic filtering is managed separately, reducing upfront spend. Application: Plants with existing harmonic mitigation strategies. Feature: CSA Certified (Canada Only). Business Impact: Enhances regulatory compliance and traceability for Canadian projects, simplifying procurement governance. Application: Canadian facilities with strict safety and documentation requirements. Feature: Robust physical footprint and installation-ready configuration. Business Impact: Easier integration with existing MV switchgear and reduced installation time. Application: New builds and retrofit projects in industrial environments.

Get a Quick Quote for a Eaton 1800MV3AI41FGMW

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 1800MV3AI41FGMW? Enquire Now

FAQs

The 1800MV3AI41FGMW is designed for 4160 V, 60 Hz medium-voltage systems and integrates with standard MV switchgear architectures. Ensure clearance for the large cabinet footprint (width 135 in, height 91 in, depth 49 in) and proper bus connections. CSA certification aids with Canadian regulatory alignment during procurement and installation.
Key specs include 1800 kVAR capacity, 4160 V operation at 60 Hz, dimensions of 49 in length, 91 in height, and 135 in width, with a total weight of 6500 lb. The catalog number is 1800MV3AI41FGMW and it carries CSA Certification for Canada.
CSA Certification is indicated as Canada Only for this model, ensuring compliance with Canadian electrical safety and performance standards. If you operate outside Canada, verify regional certifications or additional approvals with Eaton or local authorities before deployment.
Benefits include improved power factor, reduced reactive power penalties, and tighter voltage regulation, which translate to lower energy costs and enhanced equipment performance. The automated VAR control reduces manual switching, increases reliability, and supports regulatory compliance in industrial facilities and substations.
Plan for the unit’s footprint (approximately 135 in W x 91 in H x 49 in D) and 6500 lb weight, and ensure adequate mechanical support and clearances. Confirm 4160V, 60 Hz compatibility with existing MV switchgear, and coordinate with electrical code requirements and CSA documentation for a smooth deployment.