Eaton 35MM240R1240C94 Commercial Meter Stack - UL Listed
Part Number: 35MM240R1240C94
Quick Summary
Introducing the Eaton 35MM240R1240C94 commercial meter stack for rugged three-phase metering in industrial power distribution. Many projects stall when installers need flexible termination options or reliable field compatibility. UL Listed, this unit aligns with control panel standards and industry codes for metering assemblies. It supports top, bottom, or back terminations to fit diverse enclosures, enabling rapid retrofits. With a 400A rating and copper 1200A bus, it delivers scalable metering for industrial facilities. Engineers will appreciate the compact yet robust footprint and compatibility with 208Y/120V networks. Catalog notes support outdoor installations and rainproof cap configurations when exiting from the top. This makes it a reliable, future-ready solution for utility-grade metering projects.
Product Information
Extended Description
35MM240R1240C94 Eaton: Eaton 35MM commercial meter stack, 3-Phase Module, 400A, K-frame included secondary breaker, (1) 200A and (1) 400A breaker installed, 400A socket, 208Y/120V, Ringless, Cu 1200A bus, Lever bypass, Five-jaws, 2 sockets
Product Name
Eaton 35MM commercial meter stack
Catalog Number
35MM240R1240C94
UPC
786689165925
Product Length/Depth
66.625 in
Product Height
8.75 in
Product Width
19.375 in
Product Weight
320 lb
Certifications
UL Listed
Catalog Notes
Main tenant feeders can exit top, bottom, or back, If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap. 120/240V, single-phase, three-wire systems and 208Y/120V network metering
Type
Plug-in socket
Number of jaws
Five-jaw
Number of sockets
2
Phase
Three-phase in, single-phase out
Amperage Rating
400A
Residential and Light Commercial, Metering Products, Volume 1 Tab 4
Eaton Specification Sheet - 35MM240R1240C94
Three-phase metering with a 400A capacity uses a five-jaw, plug-in socket design for secure, low-resistance connections. This reduces contact resistance and speeds commissioning, delivering more reliable energy data at scale. It is well suited for 208Y/120V networks and three-phase in, single-phase out metering in commercial and light industrial environments. Flexible termination options include top, bottom, or back exits to accommodate a range of enclosure layouts. The capability minimizes field rewiring and enclosure redesign, accelerating project timelines and reducing install risk. In practice, it supports retrofit programs and new-build projects where site constraints vary. Inline K-frame secondary breaker and lever bypass are integrated into the assembly. This simplifies installation, enhances fault isolation, and speeds maintenance during commissioning or after-sell service. It is ideal for utility-grade metering and service-transfer scenarios in demanding power distribution systems. Copper 1200A bus provides a low-impedance path for high current. This design reduces voltage drop and improves measurement accuracy under high-load conditions. It’s beneficial for large commercial facilities and data centers where load profiles can spike. Ringless construction and robust enclosure compatibility enable durable outdoor installations. Catalog notes support rainproof hubs if top exiting is used, expanding weather-resilient metering options. This reduces enclosure customization and protects metering assets in exposed environments. UL Listed certification confirms compliance with recognized safety standards for meter stacks. This credential helps streamline procurement and installation within regulated facilities and projects. The combination of rugged construction and UL certification delivers dependable long-term performance in industrial power distribution.
Get a Quick Quote for a Eaton 35MM240R1240C94
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 35MM240R1240C94?
Enquire Now
FAQs
This meter stack supports top, bottom, and back exit terminations, enabling flexible integration into a wide range of enclosures. The ability to adapt to existing panel cutouts reduces retrofit risk, speeds field installation, and minimizes wiring rearrangements while preserving access for service and maintenance.
The unit is a 400A, three-phase in, single-phase out meter stack with two sockets and five-jaw plug-in sockets. It operates with 208Y/120V networks and 120/240V configurations, and uses a copper 1200A bus. These specs support accurate load measurement in mid-size commercial and light industrial installations.
Yes, the product is UL Listed, confirming compliance with recognized safety standards for meter stacks. Catalog notes support outdoor applications with appropriate rainproof cap configurations for top exits, making it suitable for exterior metering installations in varying weather conditions.
The five-jaw, plug-in socket design provides secure, low-resistance connections that improve measurement stability and reduce wiring complexity. With two sockets and a 400A rating, the stack accommodates higher load profiles and simplifies wiring layouts in compact electrical rooms.
Built around a robust Cu 1200A bus and a durable enclosure footprint, the unit is designed for long-term reliability in demanding environments. Regular inspection of terminations, connectors, and external housing, along with periodic verification of meter performance, helps maintain accuracy and reduces unscheduled downtime.