Eaton commercial meter stack 37MM240R124024 - UL Listed

Part Number: 37MM240R124024
Manufacturer
Eaton
Part number
37MM240R124024

Quick Summary

The Eaton commercial meter stack 37MM240R124024 delivers compact, modular power metering for 3-phase commercial facilities. It eliminates installation guesswork by integrating a 400A bus, two sockets, lever bypass, and factory-installed breakers in a single enclosure. UL Listed certification underpins safety and regulatory compliance for commercial metering installations. The unit supports 208Y/120V service with ringless cover, 1200A aluminum bus, and factory A-B phase balance to simplify commissioning. Designed to streamline procurement and maintenance, it reduces on-site wiring, accelerates panel upgrades, and lowers total cost of ownership for data centers, retailers, and light industrial facilities. This combination addresses common project risks, from miswiring to slow commissioning, with predictable performance.

Product Information

Extended Description

37MM240R124024 Eaton: 37MM-3-Phase Commercial Meter Stack Modules, 400A, K-frame included secondary breaker, (1) 250A and (1) 400A breaker installed, 400A socket, 208Y/120V, Ringless, Al 1200A bus, Lever bypass, Seven-jaws, 2 sockets, Factory A-B phase balance
Product Name
Eaton commercial meter stack
Catalog Number
37MM240R124024
UPC
782116995646
Product Length/Depth
66.625 in
Product Height
8.75 in
Product Width
19.375 in
Product Weight
320 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Number of sockets
2
Amperage Rating
400A
Cover
Ringless
High amperage with two sockets is a core feature, enabling up to 400A service in a single stack. This reduces equipment diversity on site and minimizes spare-part inventories, delivering greater project predictability and shorter lead times. In practice, operators can specify one unit to serve multiple tenants or critical loads, simplifying procurement and commissioning for office complexes and light industrial facilities. Pre-installed internal breakers—one 250A and one 400A—and a dedicated 400A socket streamline wiring and testing during the build phase. The business impact is a shorter installation window, lower labor costs, and fewer field modifications that can cause delays. This configuration is well-suited for 3-phase commercial feeders, retail storefronts, data centers, and other multi-load applications where space is constrained. Ringless cover reduces physical damage risk during handling and simplifies inspection access. The lever bypass provides safe service isolation without full disconnection, supporting safer maintenance windows. With seven jaws and two sockets, the unit accommodates flexible conductor routing and reduces rework in complex bus configurations. Aluminum 1200A bus delivers a robust current path with low impedance, improving overall voltage regulation under heavy load. The result is lower voltage drop, better power quality, and enhanced protection coordination for downstream equipment. This bus design supports scalable upgrades as facility loads grow. Factory A-B phase balance helps ensure even loading across three phases, reducing neutral currents and motor heat. The measured balance translates to longer equipment life and fewer nuisance trips during peak demand. When paired with 208Y/120V service and precise metering, it supports reliable energy management for commercial operations.

Get a Quick Quote for a Eaton 37MM240R124024

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 37MM240R124024? Enquire Now

FAQs

When planning installation, ensure access to a 208Y/120V supply and provide adequate clearance for the 66.625 in depth and 19.375 in width enclosure. Take advantage of the ringless cover, two sockets, lever bypass, and pre-installed breakers to minimize field wiring. Verify alignment with downstream equipment and confirm phase balance requirements to optimize performance.
A 400A rating supports higher service feeders in multi-tenant or light industrial facilities, reducing the need for multiple meters. This enhances safety by consolidating metering and protection in a single unit, while enabling easier fault isolation and maintenance. Properly matching the load profile to the stack improves voltage stability and reduces unplanned outages.
Yes, the unit is designed for 208Y/120V service, which is common in commercial environments. This compatibility simplifies panel integration, ensures correct voltage regulation for downstream equipment, and supports accurate energy metering for load balancing and demand management. It also aligns with typical building electrical codes and utility requirements.
UL Listed certification indicates compliance with recognized safety standards for electrical equipment, reducing risk during installation and operation. For this meter stack, UL Listing signals dependable construction, safe disconnect features, and suitability for commercial metering applications. Certification can streamline audits, inspections, and warranty eligibility with Eaton’s policy backing.
The stack reduces on-site wiring time, minimizes field modifications, and lowers labor costs through pre-installed breakers and a compact, integrated design. Its durable 1200A aluminum bus and ringless cover support easier maintenance and longer service intervals. Over the life of a facility, these efficiencies translate to faster project completion and lower total cost of ownership.