Eaton 3MM212R Meter Stack Residential - UL Listed

Part Number: 3MM212R
Manufacturer
Eaton
Part number
3MM212R

Quick Summary

Eaton 3MM212R Meter Stack Residential is a compact group metering solution designed for multi-tenant and light commercial buildings. Engineers often struggle with space constraints, wiring complexity, and service reliability in shared-meter installations. UL Listed certification underpins safety and compliance, and its indoor/outdoor enclosure supports flexible siting across utility requirements. By delivering centralized metering with a robust 125A rating and aluminum bus, it helps streamline procurement and improve energy management outcomes.

Product Information

Extended Description

3MM212R Eaton: Eaton's Three-Phase Residential Meter Stack Module, Group Metering Type, 125A, Aluminum Bus 800 Ampere, No bypass, Indoor/outdoor, Five-jaws, 2 Sockets, Three-phase in, single-phase out, Ring Security, 120/208V
Product Name
Eaton residential meter stack
Catalog Number
3MM212R
UPC
786849051969
Product Length/Depth
40 in
Product Height
8 in
Product Width
15 in
Product Weight
52 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Type
Group Metering
Utility approvals
MD : First Energy (Potomac Edison) AL : Alabama Power DC : Atlantic City Electric / Delmarva (Connectiv) DE : Atlantic City Electric / Delmarva (Connectiv) MD : Atlantic City Electric / Delmarva (Connectiv) NJ : Atlantic City Electric / Delmarva (Connectiv) TX : CenterPoint Energy (HL&P/Reliant) NC : Dominion VA : Dominion MI : DTE Energy (Detroit Edison) NM : El Paso Electric TX : El Paso Electric MO : Empire District Electric OK : Empire District Electric AR : Entergy LA : Entergy MS : Entergy TX : Entergy CA : City of Los Angeles - DWP (LADWP) AZ : Southern California Edison CA : Southern California Edison CA : Pacific Gas and Electric (PG&E) CA : Sacramento Municipal Utility District (SMUD) CA : PacifiCorp/Pacific Power/Rocky Mountain Power ID : PacifiCorp/Pacific Power/Rocky Mountain Power OR : PacifiCorp/Pacific Power/Rocky Mountain Power UT : PacifiCorp/Pacific Power/Rocky Mountain Power WA : PacifiCorp/Pacific Power/Rocky Mountain Power WY : PacifiCorp/Pacific Power/Rocky Mountain Power HI : Hawaiian Electric MT : NorthWestern Energy NE : NorthWestern Energy SD : NorthWestern Energy WY : NorthWestern Energy MD : Baltimore Gas and Electric DC : PEPCO MD : PEPCO AZ : Tucson Electric Power/ UniSource AZ : Sulphur Springs Valley Electric Coop IN : Indianapolis Power and Light (IP&L)
Interrupt rating
Depends on selected main circuit breaker
Enclosure
Indoor/outdoor
Secondary circuit breaker
BR2_, BRH2_, BRHH2_
Bus Rating
800 A
Phase
Three-phase in, single-phase out
Voltage rating
120/208V
Amperage Rating
125A
Bus material
Aluminum
Bypass
None
Number of jaws
Five-jaw
Number of sockets
2
Phase balance
A-B
Security
Ring
Three-phase in, single-phase out metering with five jaws and two sockets simplifies the connection topology while reducing cabinet footprint and wiring points of failure, which translates to faster installs and lower labor costs. The 800 A bus rating on an aluminum bus delivers high current capacity with lighter weight and easier handling, improving long-term reliability in dense installations. Indoor/outdoor enclosure versatility enables installation in varied environments, reducing the need for separate enclosures and enabling consistent performance across locations. Compatibility with secondary circuit breakers BR2_, BRH2_, BRHH2_ provides flexible protection options, simplifying upgrades and maintenance while minimizing spare-part inventories. The included warranty—Eaton’s 25-000 policy, one year from installation or eighteen months from shipment—lowers lifecycle risk and supports predictable procurement budgeting. Utility approvals reflected in the specification set indicate broad compatibility with major utilities, reinforcing compliance confidence for commissioning teams. By design, bypass is None, which minimizes unnecessary failure points and supports straightforward fault isolation during service events. This solution is well-suited for commercial-residential transitions where centralized metering accelerates energy analytics and bill-back processes.

Get a Quick Quote for a Eaton 3MM212R

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 3MM212R? Enquire Now

FAQs

The 3MM212R is a group metering module with three-phase in and single-phase out capability, featuring five jaws and two sockets for flexible feeder connections. It is designed for indoor/outdoor use and works with compatible secondary breakers BR2_, BRH2_, BRHH2_. Verify utility approvals for your region and ensure the main circuit breaker rating matches system requirements to achieve the intended interrupt performance.
The interrupt rating is dependent on the selected main circuit breaker installed with the meter stack. The module itself supports an 800 A bus rating with a 125 A amperage rating, and the actual interrupt capability is defined by the main breaker you pair with the unit, ensuring it meets system fault considerations.
Yes. The device is a Three-phase in, Single-phase out group metering module with a 125A rating and aluminum bus, tailored for residential group metering and light commercial applications. Its five-jaw, two-socket configuration supports efficient feed distribution, while indoor/outdoor enclosure compatibility accommodates diverse installation sites and simplifies energy accounting.
The 3MM212R is UL Listed, providing recognized safety and compliance for metering hardware in residential and light commercial settings. It also lists extensive utility approvals in its specifications, supporting acceptance by multiple utilities and streamlining commissioning in common market territories.
Eaton’s warranty policy for this product offers one year from installation or eighteen months from shipment, whichever comes first. This, combined with durable aluminum bus construction, robust group metering capability, and flexibility with BR2_BRH2_BRHH2 breakers, contributes to reduced lifecycle risk, faster deployment, and lower total cost of ownership for meter stack deployments.