Eaton LV AutoVAR 600 capacitor bank improves power factor for three-phase industrial systems. Too often operators face energy waste, tariff penalties, and voltage swings when PF is neglected. Key certifications include UL Listed, CSA Certified, UL 508A, and IEEE Std. 18, ensuring safe, compliant operation in demanding facilities. Designed for 480V systems, the AutoVAR 600 avoids costly misconfigurations with a robust main breaker and fuses and heavy-duty capacitor cells. Implementing this solution translates to reduced energy costs, steadier voltage profiles, and improved reliability across manufacturing lines and automation projects. The unit supports scalable PF correction with 8 x 50 kvar steps, enabling precise tuning to your site load profile.

Product Information

Extended Description

400TPHSR431M Eaton: Eaton AutoVAR 600 Capacitor Bank, 481A, 60 Hz, Three-phase, 480V, Main breaker and fuses, Heavy duty capacitor cells, Power Factor Correction, 8 x 50 kvar, 400 kVAR
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
400TPHSR431M
UPC
786685924441
Product Length/Depth
25 in
Product Height
80 in
Product Width
41.3 in
Product Weight
1000 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed CSA Certified UL 508A CSA Std. C22.2 No. 190 UL 810 IEEE Std. 18
Type
Power Factor Correction
Amperage Rating
481A
Frequency rating
60 Hz
Options
Heavy duty capacitor cells
Phase
Three-phase
Voltage rating
480 V
kVA rating
400 KVR
Protection
Main breaker and fuses
Step X kVAR
8 x 50 kVAR
High-capacity PF correction: This unit delivers up to 400 kVAR through eight 50 kvar steps, enabling substantial reduction in reactive power and improved power factor. Business impact: lower energy bills, reduced demand charges, and better utility compliance. Application: large motors, pumps, and conveyors in manufacturing and process plants. Heavy-duty capacitor cells: Built to withstand industrial environments, these cells offer longer service life and lower maintenance intervals. Business impact: reduced replacement costs and fewer outage risks. Application: continuous operation in demanding facilities with high switching loads. Main breaker and fuses included: Integrated protection enables safe startup, fault isolation, and coordinated protection with existing switchgear. Business impact: safer maintenance, faster fault resolution, and easier code compliance. Application: retrofits and new installations in controls centers and MCC rooms. 480 V three-phase compatibility: Designed for standard plant power distribution, simplifying integration with existing electrical rooms and switchgear. Business impact: faster commissioning, lower integration risk, and scalable expansion. Application: facility upgrades, new lines, and automation projects. Certifications and safety: UL Listed, CSA Certified, UL 508A, CSA Std. C22.2 No. 190, UL 810, IEEE Std. 18. Business impact: strengthens audit readiness, regulatory compliance, and supplier qualification. Application: industries with strict safety and reliability requirements. Space and weight considerations: Dimensions 25 in D × 41.3 in W × 80 in H and weight of 1000 lb require planning in electrical rooms. Business impact: informs layout, cooling needs, and crane/handling considerations during installation. Application: retrofit projects and new builds where footprint and load calculations matter.

Get a Quick Quote for a Eaton 400TPHSR431M

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 400TPHSR431M? Enquire Now

FAQs

The unit requires a three-phase 480V supply at 60 Hz and adequate space in the electrical room to accommodate dimensions of 25 inches depth, 41.3 inches width, and 80 inches height. With a weight around 1000 pounds, plan for proper lifting gear and ventilation. It connects to the main switchgear via a dedicated feeder and includes a main breaker and fuses for safe, code-compliant integration.
Key specs include a 400 kVAR total rating achieved through 8 x 50 kvar steps, 481A amperage rating, 60 Hz frequency, and 480 V three-phase voltage. This configuration delivers precise reactive-power management, enabling rapid PF improvements and better control of demand charges for industrial motors and drives.
Yes. The unit is UL Listed and CSA Certified, with additional compliance to UL 508A, CSA Std. C22.2 No. 190, UL 810, and IEEE Std. 18. These certifications support safe operation, electrical-code compliance, and reliability in regulated industrial environments.
Warranty terms specify one year from installation or eighteen months from shipment, whichever occurs first, per Eaton Selling Policy 25-000. Post-sale support includes access to Eaton datasheets and specification sheets, with options for service coordination, spare parts, and installation guidance to maintain optimum PF performance.
By delivering up to 400 kvar of PF correction, the unit reduces reactive power, lowers energy costs, and minimizes demand charges. It also stabilizes voltage during motor starts and drives operation, improving equipment life and process uptime. The 480 V three-phase configuration supports scalable upgrades within existing automation and power-distribution infrastructure.