Eaton 400TPHSR431W AutoVAR 600 Capacitor Bank - UL Listed

Part Number: 400TPHSR431W
Manufacturer
Eaton
Part number
400TPHSR431W

Quick Summary

Eaton LV AutoVAR 600 capacitor bank delivers automated power-factor correction for large industrial facilities. It helps reduce energy waste and PF penalties by automatically adjusting reactive power in a 480 V three-phase system. The unit carries CSA Certified and UL Listed alongside UL 508A and IEEE 18, underscoring safety and electrical reliability in demanding environments. With a NEMA 3R enclosure and heavy-duty capacitor cells, installation supports outdoor or harsh-area deployments, while 8 x 50 kvar steps provide precise PF tuning up to 400 kvar total. By improving power quality, facilities see lower utility costs, steadier voltage profiles, and a faster return on investment when managing motor loads and drives.

Product Information

Extended Description

400TPHSR431W Eaton: Eaton AutoVAR 600 Capacitor Bank, 481A, 60 Hz, Three-phase, 480V, Fuses, Heavy duty capacitor cells, NEMA 3R enclosure, Power Factor Correction, 8 x 50 kvar, 400 kVAR
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
400TPHSR431W
UPC
786685924519
Product Length/Depth
25 in
Product Height
80 in
Product Width
41.3 in
Product Weight
960 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
CSA Certified UL Listed UL 508A CSA Std. C22.2 No. 190 UL 810 IEEE Std. 18
Type
Power Factor Correction
Amperage Rating
481A
Frequency rating
60 Hz
Options
Heavy duty capacitor cells, NEMA 3R enclosure
Phase
Three-phase
Voltage rating
480 V
kVA rating
400 KVR
Protection
Fuses
Step X kVAR
8 x 50 kVAR
Feature → Business Impact → Application: The AutoVAR 600 delivers automated, responsive power-factor correction, reducing reactive power and lowering energy costs across peak and off-peak periods. This translates to measurable utility savings and improved motor efficiency in high-load production lines and pumps. Feature → Application: It’s designed for three-phase, 480 V networks, making it suitable for manufacturing floors, processing plants, and large facilities where multiple motors and drives operate simultaneously. Feature → Business Impact → Application: With 8 x 50 kvar steps (total 400 kvar), the system offers precise PF tuning as load profiles shift, ensuring consistent voltage stability and compliance with utility requirements in facilities with variable demand. Feature → Application: Heavy-duty capacitor cells housed in a NEMA 3R enclosure enable reliable outdoor or rugged-area operation, reducing maintenance cycles and enabling easier installation near outdoor switchgear. Feature → Business Impact → Application: Fuses provide essential protection, supporting safer operation and simplifying regulatory compliance during long-term maintenance. Feature → Application: The 25 in L x 41.3 in W x 80 in H footprint and 960 lb weight are compatible with common LV switchgear layouts, facilitating straightforward integration and fast deployment in existing electrical rooms. Certifications such as CSA Certified, UL Listed, UL 508A, and IEEE 18 reinforce reliability for regulated environments, while the one-year warranty (or 18 months from shipment) offers procurement-ready risk mitigation for asset management.

Get a Quick Quote for a Eaton 400TPHSR431W

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 400TPHSR431W? Enquire Now

FAQs

The capacitor bank is designed for three-phase 480 V systems and fits typical LV switchgear setups. It uses a NEMA 3R enclosure with fuses and heavy-duty capacitor cells, supporting outdoor or rugged-area installations. It can be integrated alongside standard LV equipment in facilities with motor loads and drives, provided the enclosure and connection clearances meet local codes.
It automates power-factor correction by supplying reactive power as loads vary, reducing reactive energy and PF penalties. The result is lower energy costs, steadier voltage profiles, and reduced stress on motors and drives, improving overall equipment efficiency and extending asset life in continuous production environments.
Yes. The unit uses a NEMA 3R enclosure and heavy-duty capacitor cells, making it appropriate for outdoor or harsh environments. Protective fusing and enclosure design support weather resistance and safe operation, reducing the need for indoor space and enabling placement near external switchgear where reactive power is generated.
The capacitor bank is CSA Certified and UL Listed, with UL 508A, CSA Std. C22.2 No. 190, UL 810, and IEEE Std. 18 certifications. These credentials support electrical safety, performance reliability, and regulatory compliance in many industrial markets and data centers.
With an 8 x 50 kvar configuration (400 kvar total) and automatic PF control, facilities typically see reduced utility penalties and energy costs, delivering faster ROI. The solution includes a one-year warranty from installation (or 18 months from shipment) and standard maintenance considerations centered on periodic inspection of fuses and capacitor banks to sustain performance.