Eaton 500TPCSR631M LV AutoVAR Capacitor Bank - UL/CSA
Part Number: 500TPCSR631M
Quick Summary
Eaton LV AutoVAR 600 capacitor bank enables automated reactive power control for 600 V distribution in industrial facilities. Facilities often struggle with fluctuating voltage and rising demand charges, making reliable VAR management essential. Certifications UL 508A, CSA Std. C22.2 No. 190, UL 810, and IEEE Std. 18 provide confidence for panel integration and safe operation in harsh environments. This three-phase capacitor bank delivers fast response and scalable capacity, while standard dimensions and a robust enclosure support straightforward installation in dedicated cabinets or switchgear. Designed for power factor correction and harmonic-aware operation, it integrates with existing feeders for efficient commissioning. Customers benefit from reduced energy charges, improved voltage profiles, and simplified procurement with a single Eaton solution across maintenance and plant upgrades.
Product Information
Extended Description
500TPCSR631M Eaton: Eaton AUTO CAP BANK, FLR MTD, 600V, 500 KVAR W/800 AMP CB
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
500TPCSR631M
UPC
786685376035
Product Length/Depth
26.25 in
Product Height
78 in
Product Width
38.5 in
Product Weight
1019 lb
Certifications
UL 508A CSA Std. C22.2 No. 190 UL 810 IEEE Std. 18
Type
AutoVAR
Phase
Three-phase
Feature: 600 V rating with a 500 KVAR capacity enables substantial reactive power compensation for motors and non-linear loads. Business Impact: enhanced power factor reduces line currents, lowers utility demand charges, and minimizes voltage drop along feeders. Application: ideal for manufacturing lines and process facilities where high motor start-up currents and variable loads are common. Feature: AutoVAR control with fast response and an 800 A circuit breaker. Business Impact: delivers automatic VAR management that stabilizes voltage and supports peak shaving, reducing plant-wide energy spend. Application: retrofit or new builds in assembly lines, presses, and extrusion where stable voltage is critical to product quality. Feature: Three-phase design and a robust enclosure with dimensions of 26.25 in length, 78 in height, and 38.5 in width, plus a weight of 1019 lb. Business Impact: predictable footprint simplifies space planning and compliant mounting in standard switchgear or dedicated cabinets. Application: centralized motor control centers and feeder panels. Feature: Certifications UL 508A, CSA Std C22.2 No 190, UL 810, and IEEE Std 18. Business Impact: regulatory alignment reduces audit risk and accelerates approvals in regulated environments. Application: essential for facilities with strict safety and interoperability requirements. Feature: Comprehensive data and availability of Eaton specification sheets. Business Impact: streamlines procurement and ensures compatibility across upgrades. Application: supports fast, single-source installations in new builds and modernization projects.
Get a Quick Quote for a Eaton 500TPCSR631M
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 500TPCSR631M?
Enquire Now
FAQs
Installation requires mounting within a dedicated cabinet or compatible switchgear, ensuring proper clearance around the enclosure, and wiring to the 800 A circuit breaker and bus connections per the Eaton spec sheet. Verify voltage class and phase connections, perform a thorough insulation check, and confirm grounding and protection devices are configured to meet UL 508A and IEEE 18 requirements. A qualified electrician should complete commissioning, and Eaton documentation should be consulted for any site-specific adjustments.
Key specs include a 600 V rating, 500 KVAR reactive power capacity, and an 800 A circuit breaker. It is a three-phase AutoVAR capacitor bank with overall dimensions of 26.25 in length, 78 in height, and 38.5 in width, weighing 1019 lb. It carries UL 508A, CSA C22.2 No. 190, UL 810, and IEEE 18 certifications, with UPC 786685376035.
Yes. The model provides automatic reactive power control suitable for facilities with variable motor loads and high startup currents. Its 500 KVAR capacity supports significant PF improvement, reducing current and demand charges. The three-phase design simplifies integration with existing switchgear, and the robust enclosure is designed for industrial environments, making it a practical fit for manufacturing lines and processing equipment.
The unit is certified UL 508A, CSA Std C22.2 No 190, UL 810, and IEEE Std 18. These certifications verify electrical safety, panel accessibility, and performance in industrial settings. They matter for regulatory compliance, safer installations, and smoother audits in sectors with strict safety codes and interoperability requirements.
Expect benefits from power factor correction and voltage stabilization that can lower energy charges over time. Maintenance typically includes periodic enclosure inspection, connection verification, and thermal checks as recommended in the Eaton datasheet. A well-maintained AutoVAR bank also reduces equipment fatigue by stabilizing voltages, contributing to longer motor and drive life and predictable plant performance.