Eaton 500TPHSR631 LV AutoVAR 600 capacitor bank - UL508A

Part Number: 500TPHSR631
Manufacturer
Eaton
Part number
500TPHSR631

Quick Summary

The Eaton LV AutoVAR 600 capacitor bank provides reactive power compensation for 3-phase 600 V industrial feeders. Facilities often struggle with poor power factor, voltage fluctuations, and rising demand charges that erode profitability. It carries UL 508A, UL 810, CSA C22.2 No. 190, and IEEE 18 certifications to support safety, compliance, and dependable operation. With a rugged floor-mount NEMA 1 steel enclosure and 600 V three-phase capability, it delivers measurable business value by improving power quality and reducing utility costs. Designed for heavy-duty industrial use, the unit integrates with existing motor drives and feeders, and Eaton provides data on efficiency gains and maintenance planning. This combination supports ongoing reliability and lower lifecycle costs.

Product Information

Extended Description

500TPHSR631 Eaton: Eaton Autovar 600, 600V, 500 kVAR, 60 Hz, NEMA 1, Includes heavy duty capacitor cells, seperate CT required
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
500TPHSR631
UPC
786685954486
Product Length/Depth
25 in
Product Height
80 in
Product Width
41.3 in
Product Weight
1050 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL 508A CSA Std. C22.2 No. 190 UL 810 IEEE Std. 18
Amperage Rating
480A
Frequency rating
60 Hz
Mounting
Floor
Phase
Three-phase
Voltage rating
600 V
Enclosure
NEMA 1
Enclosure material
Steel
Enclosure size
L
kVA rating
500 kVA
Step X kVAR
10 x 50 kVAR
Feature: 600 V three-phase, 500 kVA rating; Business Impact: enables substantial reactive power correction for large motor loads, delivering improved power factor and reduced utility demand charges; Application: manufacturing lines and process plants require robust, scalable compensation. Feature: NEMA 1 steel enclosure with floor mounting; Business Impact: withstands dusty factory environments while allowing safe, accessible service; Application: floor-mounted installations in industrial facilities. Feature: Heavy-duty capacitor cells with 10 x 50 kVAR stepping; Business Impact: precise, staged correction that matches load profile and minimizes overshoot; Application: staged commissioning for evolving automation needs. Feature: Separate current transformer requirement; Business Impact: ensures accurate monitoring and integration with existing control systems; Application: seamless retrofits and protection coordination. Feature: Certifications UL 508A, UL 810, CSA, IEEE 18; Business Impact: regulatory compliance and safety assurance; Application: regulated facilities across manufacturing and maintenance environments.

Get a Quick Quote for a Eaton 500TPHSR631

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 500TPHSR631? Enquire Now

FAQs

The unit is designed for 600 V three-phase systems, supporting 60 Hz operation and a 480 A current rating. It mounts on the floor in a NEMA 1 enclosure and integrates with standard power distribution layouts. For retrofits, ensure physical clearance for the 80 inch height and 41.3 inch width, plus alignment with existing CT circuits for proper control. This compatibility supports straightforward installation in typical industrial facilities.
Key specs include a 500 kVA kVAR rating, 480 A amperage rating, 60 Hz frequency, 600 V voltage rating, three-phase configuration, and a floor-mounted NEMA 1 enclosure made of steel. The assembly uses heavy-duty capacitor cells and requires a separate current transformer (CT) for monitoring. This combination enables scalable, precise power factor correction aligned with motor loads and process demands.
The unit carries UL 508A for industrial control panels, UL 810 for electrical equipment, CSA Std. C22.2 No. 190, and IEEE 18. These certifications demonstrate electrical safety, reliability, and compatibility with industry standards, which simplifies procurement for regulated environments and reduces risk during audits or inspections.
Expect improved power factor, reduced reactive power demand, and lower utility charges due to optimized voltage and current, especially with large motor loads. The NEMA 1 enclosure and floor mounting offer robust protection in harsh environments, while the 10 x 50 kVAR stepping enables staged compensation to match changing load profiles and minimize maintenance costs over time.
Plan for adequate floor space and vertical clearance to accommodate the 80 inch height and 41.3 inch width, plus the 1050 lb weight. Ensure proper mounting surface, access to a separate CT for control, and ventilation appropriate to a steel, enclosed cabinet. Coordinate with your electrical room layout to accommodate wiring, protection devices, and future scalability.