Eaton 550TPHSR431MW Capacitor Bank - UL Listed

Part Number: 550TPHSR431MW
Manufacturer
Eaton
Part number
550TPHSR431MW

Quick Summary

Eaton LV AutoVAR 600 capacitor bank provides power factor correction for large 480V three-phase industrial systems. Facilities often struggle with efficiency penalties and equipment wear from poor PF; this bank stabilizes voltage, reduces penalties, and supports smoother operation. Certified UL Listed and CSA Certified, with UL 508A, CSA Std. C22.2 No. 190, UL 810, and IEEE Std. 18 compliance, it meets rigorous control panel and industrial safety standards. By delivering scalable PF correction through 11 x 50 kVAR steps in a 550 kVAR package, it enables reliable, cost-effective energy management while integrating easily with existing electrical architectures and protection schemes.

Product Information

Extended Description

550TPHSR431MW Eaton: Eaton AutoVAR 600 Capacitor Bank, 662A, 60 Hz, Three-phase, 480V, Main breaker and fuses, Heavy duty capacitor cells, NEMA 3R enclosure, Power Factor Correction, 11 x 50 kvar, 550 kVAR
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
550TPHSR431MW
UPC
786685924618
Product Length/Depth
25 in
Product Height
80 in
Product Width
41.3 in
Product Weight
1160 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed CSA Certified UL 508A CSA Std. C22.2 No. 190 UL 810 IEEE Std. 18
Type
Power Factor Correction
Amperage Rating
662A
Frequency rating
60 Hz
Options
Heavy duty capacitor cells, NEMA 3R enclosure
Phase
Three-phase
Voltage rating
480 V
kVA rating
550 KVR
Protection
Main breaker and fuses
Step X kVAR
11 x 50 kVAR
Feature: High total kVAR with 11 x 50 kVAR steps and 550 kVAR total; Business Impact: Precise, scalable PF correction that matches load growth without overcapitalizing; Application: Large manufacturing plants needing dynamic correction across motor drives and process loads. The three-phase 480 V rating aligns with common industrial power systems, enabling straightforward retrofits and new installations. Feature: Main breaker and fuses provide robust protection; Business Impact: Safer startups, easier maintenance, and reduced fault propagation; Application: Facilities requiring compliant, fail-safe operation in control panels. Feature: Heavy-duty capacitor cells extend service life in demanding environments; Business Impact: Lower maintenance costs and higher reliability; Application: Outdoor or semi-exposed installations with NEMA 3R enclosure. Feature: NEMA 3R enclosure enables indoor/outdoor flexibility; Business Impact: Simplified siting and protection against weather exposure; Application: Plants with outdoor electrical rooms. Feature: Certifications including UL Listed, CSA Certified, UL 508A, and IEEE 18 compliance; Business Impact: Streamlined procurement and regulatory alignment; Application: Regulated industries and panel manufacturers seeking verified compliance.

Get a Quick Quote for a Eaton 550TPHSR431MW

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 550TPHSR431MW? Enquire Now

FAQs

Plan for a sturdy mounting surface, proper clearances for heat dissipation, and space for wiring access to the main breaker and fuses. Ensure compatibility with a 480V three-phase system and confirm outdoor or indoor placement aligns with the NEMA 3R enclosure requirements. Verify panel ambient temperature ratings and allow for expansion if additional 50 kVAR steps are desired in the future.
Yes. The unit is specifically rated for 480V three-phase operation with a 60 Hz frequency, 662A amperage, and a 550 kVAR total PF correction capacity distributed across 11 x 50 kVAR steps, making it compatible with common industrial power distribution architectures.
It is UL Listed and CSA Certified, with compliance to UL 508A, CSA Std. C22.2 No. 190, UL 810, and IEEE Std. 18, ensuring electrical safety, control panel compatibility, and performance reliability in regulated environments.
The 11Ă—50 kVAR stepping allows staged PF correction that adapts to load fluctuations, reducing overshoot and minimizing capacitor switching stress. This translates to faster payback, reduced utility penalties, and better voltage regulation for motor loads and drives.
The product carries Eaton’s standard warranty policy, with one year from installation or 18 months from shipment, whichever occurs first. Support includes documentation, field service guidance, and access to Eaton’s specification literature and datasheets to assist with commissioning and ongoing maintenance.