Eaton 600243MVF3C LV Unipak capacitor bank - CSA Certified
Part Number: 600243MVF3C
Quick Summary
The Eaton LV Unipak capacitor bank is designed to provide reliable reactive power compensation in three-phase industrial systems. Operators often struggle with voltage dips, motor overheating, and utility penalties tied to poor power factor. This unit carries CSA certification for electrical safety and performance, with broader industry compliance typically pursued for international deployments. Its compact footprint, accessible documentation, and Eaton compatibility streamline installation and maintenance, enabling faster ROI. By clarifying electrical loading and enabling proactive power quality management, this capacitor bank supports greener, more efficient operations across manufacturing, data centers, and process industries.
Product Information
Extended Description
600243MVF3C Eaton: Eaton 600 KVAR 2400V 3PH FIXED 3 FUSES CSA
Product Name
Eaton LV Unipak capacitor bank
Catalog Number
600243MVF3C
UPC
786685235653
Product Length/Depth
20.42 in
Product Height
36.19 in
Product Width
26.68 in
Product Weight
265 lb
Phase
Three-phase
Feature: Three-phase fixed capacitor bank provides stable reactive power support across loads. Business Impact: Reduces reactive power demand, improves power factor, and lowers utility charges, contributing to lower operating costs. Application: Suitable for manufacturing lines, heavy-duty motors, and other high-load environments where voltage stability is critical. Feature: Fixed configuration with three fuses and a CSA-rated enclosure. Business Impact: Enhances safety, reliability, and ease of maintenance while minimizing fault propagation during service events. Application: Plant upgrades and new installations in industrial facilities where safety compliance is paramount. Feature: Compact footprint and documented dimensions (20.42 in depth, 26.68 in width, 36.19 in height) and weight (265 lb). Business Impact: Simplifies equipment room planning, facilitates retrofit projects, and enables precise space budgeting. Application: Retrofit projects and new builds with tight installation envelopes. Feature: Compatibility with Eaton LV systems and standard wiring practices. Business Impact: Streamlines procurement, reduces integration risk, and speeds commissioning. Application: OEM integrations and retrofit programs across three-phase electrical networks. Feature: Access to Eaton specification sheets and robust support. Business Impact: Accelerates design verification, ensures correct installation, and supports ongoing maintenance planning. Application: Engineering teams requiring clear wiring diagrams and service guidance for long-term reliability.
Get a Quick Quote for a Eaton 600243MVF3C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 600243MVF3C?
Enquire Now
FAQs
This model is designed for three-phase 2400V operation with a fixed capacitor bank and three fuses. Installation should follow the Eaton specification sheet, including proper enclosure mounting, cable sizing for the rated voltage, fuse protection layout, and wiring to the main switchgear. Verify clearance for heat dissipation and ensure safe de-energization procedures prior to service. Proper torque on connectors and adherence to local electrical codes are essential for reliable operation.
The 600243MVF3C carries CSA certification for electrical safety and performance, which supports compliance in North American installations. For international deployments, consult regional safety standards and Eaton’s technical documentation to determine additional certifications such as CE or UL equivalents. Always verify your site’s regulatory requirements before commissioning to ensure full compliance and safety.
The LV Unipak design is intended for seamless integration within Eaton low-voltage systems and typical electrical rooms using standard 2400V three-phase wiring. While it can be incorporated into mixed environments, compatibility depends on bus connections, protective devices, and control schemes. Consulting Eaton installation guides and performing a site-specific review ensures reliable interoperability and minimizes integration risk.
Expect a measurable improvement in power factor and a reduction in reactive power demand, which translates to lower line currents and reduced utility penalties. The 600 KVAR rating at 2400V is designed for significant reactive power compensation in three-phase loads, improving motor efficiency and reducing heat losses. Actual savings depend on load profile, existing power factor, and energy tariffs; run a baseline study to quantify ROI.
Maintenance typically focuses on ensuring fuse integrity, electrical connections, and enclosure integrity remain intact. Regular inspections per Eaton’s recommendations help prevent unexpected outages and extend service life. While maintenance adds a small ongoing cost, the resulting reductions in energy waste, improved reliability, and faster return on investment often justify the capacitor bank purchase over its life cycle.