Eaton 600483MVF3 LV Unipak capacitor bank - NEMA 1, 3R, 12
Part Number: 600483MVF3
Quick Summary
The Eaton LV Unipak capacitor bank 600483MVF3 provides reliable reactive power support for industrial power systems. It helps prevent voltage dips and nuisance trips by stabilizing voltage during load swings, reducing downtime and maintenance costs. With NEMA 1, NEMA 3R, and NEMA 12 enclosure options, it suits both indoor and outdoor installations while meeting rugged industrial requirements. This fixed capacitor bank complements fixed capacitor banks with 4800 V rating and 600 kVAR, delivering scalable efficiency gains and improved power quality for engineers and procurement teams. Warranty coverage and Eaton's global support network further de-risk procurement and installation. This combination supports fast commissioning and long-term reliability in critical facilities.
Product Information
Extended Description
600483MVF3 Eaton: Eaton UNIVAR XV, Fixed Capacitor Banks, 4800V, Three-phase, 600 kVAR, Three-fuse, NEMA 1, 3R, and 12, 14 ga. steel finished with durable baked-on enamel, Viewing window, top and side entry, removable front cover
Product Name
Eaton LV Unipak capacitor bank
Catalog Number
600483MVF3
UPC
786685261690
Product Length/Depth
20.42 in
Product Height
41.94 in
Product Width
20.26 in
Product Weight
238 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Catalog Notes
The wiring enclosure is gasketed to create a weatherproof, dustproof seal. Universal mounting flanges are provided for floor installation. The elimation of knockouts permits indoor/outdoor use.
Type
UNIVAR XV
Fuse type
Three-fuse
Options
Viewing window, top and side entry, removable front cover
Phase
Three-phase
Product Category
Fixed Capacitor Banks
Voltage rating
4800 V
Enclosure
NEMA 1, NEMA 3R, NEMA, NEMA 12
Enclosure material
14 gauge steel finished with durable baked-on enamel
Rating
600 kVAR
Feature UNIVAR XV capacitor bank is designed for fixed capacitor bank applications at 4800 V, three-phase, delivering 600 kVAR. Business Impact this sizing provides substantial reactive power compensation, improving power factor, reducing utility penalties, and lowering energy losses across motors and drives. Application ideal for industrial environments with large motor loads, presses, pumps, and HVAC systems seeking reliable, scalable power quality. Feature Three-fuse protection ensures bank and upstream equipment have fast-acting overcurrent protection. Business Impact minimizes fault propagation and unplanned outages, extending equipment life and reducing maintenance costs. Application suitable for utility-grade feeds where protective coordination matters, such as manufacturing lines and data centers. Feature Viewing window, top and side entry, and removable front cover streamline inspection and servicing. Business Impact reduces downtime during routine checks and fault investigations, improving maintenance efficiency. Application on-site technicians benefit from quick status checks without fully dismantling the enclosure. Feature Enclosure options include NEMA 1, NEMA 3R, and NEMA 12 with gasketed seals; this combination supports indoor and outdoor installation in dusty or damp environments. Business Impact compliance with harsh environments, weatherproofing, and dust control lowers corrosion risk and extends service life. Application ideal for factory floors, outdoor substations, and equipment rooms. Feature Durable 14-gauge steel with baked-on enamel offers tough protection against corrosion in aggressive industrial settings. The design includes universal mounting flanges for floor installation and eliminates knockouts to simplify wiring enclosure installation. Business Impact faster installation, lower labor costs, and easier retrofit. Application OEMs and maintenance teams value flexible mounting and ready-to-wire capability. Feature Warranty and service are built into the design with Eaton's global support network. Business Impact predictable ROI through reduced downtime and easier parts sourcing. Application coverage and service continuity are ensured by a global support ecosystem. Feature Compatibility with UNIVAR XV accessories and field wiring guidelines reduces engineering time. Application supports efficient integration in new builds and plant upgrades.
Get a Quick Quote for a Eaton 600483MVF3
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 600483MVF3?
Enquire Now
FAQs
Yes. The unit is a fixed three-phase UNIVAR XV capacitor bank rated at 4800 V and 600 kVAR, with universal mounting flanges for floor installation, gasketed enclosure for indoor/outdoor use, and top/side entry. Ensure matching bus rating and protections, review the three-fuse configuration, and consult Eaton's installation guidelines and the 600483MVF3 specification sheet for field wiring diagrams.
600483MVF3 provides 600 kVAR of reactive power at 4,800 V in a three-phase configuration, delivering essential power-factor support for large motor and drive loads. It uses three-fuse protection to limit fault current and prevent upstream outages, and includes a viewing window, removable front cover, and top/side entry for easy inspection and wiring. Enclosures include NEMA 1, 3R, and 12 options.
Industries with heavy, energy-intensive loads—such as manufacturing, data centers, HVAC systems, pumps, and large conveyors—benefit from improved power quality and reduced electrical penalties. The fixed 4,800 V, three-phase design supports critical drives and motors, while gasketed, weatherproof enclosures enable indoor and outdoor installations, and 600 kVAR provides scalable reactive power compensation for growing facilities.
Enclosures meet NEMA 1, NEMA 3R, and NEMA 12 protection levels, suitable for indoor and outdoor environments. The unit uses 14-gauge steel with baked-on enamel and a gasketed seal for weatherproof and dustproof performance. The warranty aligns with Eaton policy: one year from installation or eighteen months from shipment, whichever comes first.
Reactive power compensation reduces utility penalties and improves power factor, delivering energy-cost savings. With three-fuse protection and a viewing window, fault detection is quicker and service intervals are shortened, lowering maintenance spend. The unit’s rugged enclosure and Eaton support network help minimize downtime and simplify spares management, contributing to a favorable ROI over its service life.