Eaton 6023PMURF LV Unipak capacitor bank - UL Listed
Part Number: 6023PMURF
Quick Summary
Eaton LV Unipak capacitor bank is a three-phase solution for power factor correction in industrial power systems. It helps facilities improve voltage quality and reduce reactive power penalties, addressing common pain points like motor overload, nuisance trips, and higher energy costs. The design carries CSA Certified and UL Listed certifications, paired with a rugged NEMA 1/NEMA 3R enclosure for harsh environments. Built around a compact C1 frame, it delivers 60 kVAR at 240V with a 144A rating, while clear fusing and indicator lights streamline maintenance. This combination supports reliable operation, safer commissioning, and predictable total cost of ownership, aligning with procurement goals for efficiency, compliance, and long service life.
Product Information
Extended Description
6023PMURF Eaton: Eaton LV Unipak capacitor bank, UNIPAK, Low Voltage Fixed Capacitor Banks, 144A, 240V, Three-phase, 60 kVAR, Protected, Neon red blown-fuse indicating lights, Three slottedblade-type fuses, C1 Frame
Product Name
Eaton LV Unipak capacitor bank
Catalog Number
6023PMURF
UPC
782116058488
Product Length/Depth
10.6 in
Product Height
26.3 in
Product Width
12.1 in
Product Weight
69 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
CSA Certified UL Listed
Catalog Notes
Multiply the 240V kVAR rating by 0.75 to calculate the kVAR value at 208V.
Type
UNIPAK
Amperage Rating
144A
Fuse type
Three slottedblade type fuses with 200,000 ampere interrupting capacity
Phase
Three-phase
Product Category
Low Voltage Fixed Capacitor Banks
Voltage rating
240V
Enclosure
NEMA 1, NEMA 3R
Enclosure material
14 gauge steel finished with durable powder coat finish
Frame size
C1
Indicators
Red, neon blown-fuse indicating lights are protected by transparent weatherproof guard
Protection
Three fuses, three lights
Rating
60 kVAR
Feature: UNIPAK low voltage three-phase capacitor bank footprint. Business Impact: Reduces installation time and panel-space, enabling flexible retrofits and scalable expansion in existing switchgear. Application: Ideal for manufacturing lines and packaging facilities where compact, reliable PF correction is needed. Feature: 60 kVAR at 240V, 144A rating. Business Impact: Delivers targeted reactive power control with predictable energy savings and fewer utility penalties. Application: Suitable for multi-motor loads and variable-speed drives in industrial plants. Feature: Three slotted-blade fuses with 200,000 AIC and neon blown-fuse indicators. Business Impact: Improves fault isolation and reduces mean time to repair, boosting system uptime. Application: Critical in control panels and switchgear assemblies. Feature: NEMA 1 and NEMA 3R enclosure, 14-gauge powder-coated steel, C1 frame. Business Impact: Provides rugged durability and weather resistance, lowering maintenance costs. Application: Indoor or protected outdoor installations. Feature: Warranty and catalog notes. Business Impact: Clear support window with coverage for installation and shipment delays; 208V sizing note ensures correct kVAR calculation. Application: Procurement planning and field service readiness.
Get a Quick Quote for a Eaton 6023PMURF
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 6023PMURF?
Enquire Now
FAQs
Install within a standard switchgear footprint using the C1 frame, with NEMA 1 or NEMA 3R enclosure as required. It uses three slotted-blade fuses rated for 200,000 AIC and includes red neon indicating lights to show blown-fuse status. Ensure 240V three-phase supply and proper panel clearances for safe service access.
The 6023PMURF provides 60 kVAR of reactive power at 240V in a three-phase configuration, with a 144A amperage rating. This sizing supports targeted PF correction for multiple motor loads, enabling predictable energy savings while remaining compatible with standard switchgear and bus arrangements.
Yes. Its 60 kVAR rating at 240V is designed for power factor correction in facilities with motor loads and variable-speed drives. Use the 208V note from the catalog (kVAR × 0.75) to determine equivalent kVAR at 208V networks, ensuring accurate reactive-power compensation.
The unit is CSA Certified and UL Listed, meeting North American electrical-safety standards. It features three fuses with a 200,000 AIC rating and neon-operated fault indicators protected by a weatherproof guard, ensuring quick fault detection and safe operation in industrial environments.
Warranty covers one year from installation or 18 months from shipment. For maintenance, monitor the neon indicator lights and periodically inspect fuses and enclosure integrity. Keep spare three-slotted blade fuses on hand and verify voltage and current ratings match the site supply to maintain optimal PF correction.