Eaton 6063HURF Unipak capacitor bank - UL Listed
Part Number: 6063HURF
Quick Summary
6063HURF is an Eaton LV Unipak capacitor bank that improves power factor in low-voltage three-phase systems. This design helps reduce reactive power charges, stabilize voltage, and lower demand charges in manufacturing and process environments. CSA Certified and UL Listed provide third-party safety and compliance assurance, while a NEMA 12 enclosure guards the banking in dirty or damp facilities. Manufacturers benefit from easy integration with existing low-voltage fixed capacitor systems, thanks to a standard frame C1, 14 gauge steel, and a durable powder-coated finish. The 60 kVAR rating at 600 V, combined with a 58.8 A current capacity, supports scalable power factor correction in modern plants.
Product Information
Extended Description
6063HURF Eaton: Eaton LV Unipak capacitor bank, UNIPAK with Heavy-Duty Cells, Low Voltage Fixed Capacitor Systems, 58.8A, 600V, Three-phase, 60 kVAR, NEMA 12, 14 ga. steel finished with durable powder coat finish, C1 Frame
Product Name
Eaton LV Unipak capacitor bank
Catalog Number
6063HURF
UPC
782116143757
Product Length/Depth
10.6 in
Product Height
26.3 in
Product Width
12.1 in
Product Weight
52.8 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
CSA Certified UL Listed
Catalog Notes
Multiply the 240V kVAR rating by 0.75 to calculate the kVAR value at 208V.
Type
UNIPAK with Heavy-Duty Cells
Amperage Rating
58.80A
Phase
Three-phase
Product Category
Low Voltage Fixed Capacitor Systems
Voltage rating
600 V
Enclosure
NEMA 12
Enclosure material
14 gauge steel finished with durable powder coat finish
Frame size
C1
Rating
60 kVAR
Feature UNIPAK with Heavy-Duty Cells is designed for high-duty operation, delivering improved reliability in harsh industrial environments. Business Impact This reduces unplanned downtime and extends service life, lowering total cost of ownership when deployed in continuous process lines. Application Suitable for manufacturing facilities and heavy-duty motor loads that demand consistent reactive power control. Feature 58.80 A Amperage Rating and 60 kVAR at 600 V provide precise PF correction, enabling tighter voltage regulation and reduced utility penalties. Application Ideal for three-phase feeders in process facilities and HVAC systems where stable power factor drives energy savings. Feature NEMA 12 enclosure with 14 gauge steel and powder coat finish protects internal components from dust and moisture, minimizing maintenance windows. Application Suitable for control panels and equipment rooms in dirty or damp industrial settings. Feature Frame size C1 and a compact footprint simplify retrofits and panel integration, reducing installation time and labor costs. Application Works well in standard industrial racks and integrated with low voltage fixed capacitor systems. Feature CSA Certified and UL Listed to meet regulatory safety requirements, easing procurement and audits. Application Particularly important for facilities with North American electrical compliance and supplier qualification programs. Feature Catalog Notes state that multiplying the 240V kVAR rating by 0.75 yields the estimated kVAR at 208V, offering a practical sizing check for mixed-voltage plants.
Get a Quick Quote for a Eaton 6063HURF
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 6063HURF?
Enquire Now
FAQs
For installation, ensure adequate clearance and mounting within a NEMA 12, 14 gauge steel enclosure. Align with the C1 frame footprint and confirm cable entry points accommodate the 58.8 A rating. Use properly rated torque on connection hardware and follow Eaton wiring diagrams to maintain fault tolerance and safe operation in three-phase, 600 V networks.
The 6063HURF delivers 58.80 A of current and a rated 60 kVAR reactive power at 600 V. This combination supports consistent PF correction for three-phase low-voltage feeders, enabling stable voltage profiles and reduced utility penalties in industrial plants with motor drives and process loads.
Catalog notes indicate a 240 V kVAR rating can be scaled for 208 V by multiplying by 0.75. Practically, if you know the 240 V kVAR rating, apply the 0.75 factor to estimate the 208 V kVAR. This helps engineers size the bank for mixed-voltage environments while maintaining target PF improvements.
The 6063HURF is CSA Certified and UL Listed, which verifies safety and compliance with North American electrical standards. These certifications streamline procurement, satisfy internal and customer audit requirements, and reduce regulatory risk when deploying in regulated facilities and critical automation systems.
The UNIPAK design with Heavy-Duty Cells is built for reliability, minimizing maintenance downtime in continuous operation environments. By improving power factor, you can lower kVA demand and energy costs, delivering a favorable ROI over the life of the equipment. Regular visual inspections and periodic electrical testing are recommended per the Eaton specification.