Eaton 650483MVF3C LV Unipak capacitor bank - CSA
Part Number: 650483MVF3C
Quick Summary
Eaton LV Unipak capacitor bank is a high-capacity power factor correction solution for large motor loads in industrial facilities. Too often, voltage sags and utility penalties erode uptime and raise operating costs, especially in facilities with pumps, fans, or extrusion lines. This unit carries CSA Certification (Canada Only) and IEEE Std. 18 compliance, underscoring safety and performance in critical environments. With 650 KVAR at 4800 V in a three-phase configuration, it delivers measurable energy savings and improved voltage stability, while integrating with common Eaton LV switchgear and supporting long-term maintenance planning.
Product Information
Extended Description
650483MVF3C Eaton: Eaton 650 KVAR 4800V 3PH FIXED 3 FUSES CSA
Product Name
Eaton LV Unipak capacitor bank
Catalog Number
650483MVF3C
UPC
786685236360
Product Length/Depth
20.42 in
Product Height
41.94 in
Product Width
26.68 in
Product Weight
279 lb
Certifications
CSA Certified (Canada Only) IEEE Std. 18
Phase
Three-phase
Feature: 650 KVAR capacity at 4800 V. Business Impact: Reduces reactive power draw, improves power factor, and lowers peak kWh charges for heavy-inductive loads. Application: Suitable for large motors, compressors, and HVAC in manufacturing plants. Feature: Three-phase fixed capacitor bank with three fuses. Business Impact: Enhances system protection during switching events and reduces fault exposure, supporting safer maintenance and faster restoration. Application: Ideal for alignment with standard three-phase feeders in industrial facilities. Feature: CSA Certified (Canada Only) and IEEE Std. 18 compliance. Business Impact: Provides regulatory credibility and predictable performance across cross-border sites, easing procurement and testing cycles. Application: Critical for multinational operations and compliance-driven projects. Feature: Manageable footprint and weight (20.42 in L × 26.68 in W × 41.94 in H; 279 lb). Business Impact: Facilitates installation in constrained electrical rooms and simplifies crane or rack mounting. Application: Suitable for retrofit or new-build power factor correction in existing panels. Feature: UPC 786685236360 and catalog number 650483MVF3C. Business Impact: Enables straightforward ordering, inventory control, and compatibility checks with Eaton’s LV Unipak family. Application: Streamlined project planning and replacement workflows.
Get a Quick Quote for a Eaton 650483MVF3C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 650483MVF3C?
Enquire Now
FAQs
Plan for a suitable electrical room footprint to accommodate the 20.42 in L × 26.68 in W × 41.94 in H enclosure and 279 lb weight. Ensure three-fuse protection is wired into the feeder and that clearances meet local codes. Verify CSA/IEEE 18 certification requirements and coordinate with existing Eaton LV components for seamless integration.
650 KVAR at 4800 V delivers substantial reactive power compensation, raising system power factor toward unity. This reduces utility penalties, lowers kVA demand, and minimizes voltage drop under heavy inductive loads such as motors and pumps. The result is lower energy costs, improved motor performance, and extended equipment life.
Yes. The three-phase 4800 V configuration is well-suited for large HVAC systems and pump assemblies common in manufacturing. It stabilizes voltage, mitigates harmonics where applicable, and reduces reactive current. Compatibility with the Eaton LV Unipak line supports straightforward installation and future expansion within industrial power distribution schemes.
The unit is CSA Certified (Canada Only), indicating compliance with Canadian safety standards, and it references IEEE Std. 18 for capacitor bank performance and testing. These certifications help meet regulatory requirements, simplify cross-border procurement, and provide documented reliability for critical industrial applications.
ROI hinges on reduced reactive power charges and improved efficiency, particularly in facilities with heavy inductive loads. Regular maintenance includes monitoring capacitor health, inspecting fuses, and verifying insulation integrity. With CSA/IEEE 18 compliance and a robust three-fuse design, downtime is minimized during service and routine testing can be scheduled to avoid peak production periods.