Eaton 700TPCSR431 LV AutoVAR 600 - UL Listed

Part Number: 700TPCSR431
Manufacturer
Eaton
Part number
700TPCSR431

Quick Summary

Eaton LV AutoVAR 600 capacitor bank provides reactive-power management for industrial facilities. Engineers often struggle with voltage sags, poor power factor, and rising demand charges when motor loads spike. This unit carries UL Listed and CSA Certified markings, plus UL 508A and UL 810 compliance, ensuring safety and code conformity. With three-phase 480 V operation, a floor-mounted double-door enclosure, and optional IQ 250 digital metering, it fits retrofit projects and new builds alike. By integrating scalable capacity (700 kVAR) with modular 7 x 100 kVAR steps, it supports long-term efficiency and predictable ROI across manufacturing, process, and data-center adjacencies.

Product Information

Extended Description

700TPCSR431 Eaton: Eaton AUTOVAR 600, Switched Capacitor Banks, 840A, 480V, Three-phase, 700 kVAR, Floor-mounted, Double-Door Enclosure Unit, 7 x 100, L Frame, Optional molded-case circuit breaker rated 65 kAIC at 480V and 600V, Opt digital metering-IQ 250
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
700TPCSR431
UPC
786685157016
Product Length/Depth
26.25 in
Product Height
78 in
Product Width
38.5 in
Product Weight
1616 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed CSA Certified UL 508A CSA Std. C22.2 No. 190 UL 810 IEEE Std. 18
Type
AUTOVAR 600
Amperage Rating
840A
Mounting
Floor
Options
Optional molded-case circuit breaker rated 65 kAIC at 480V and 600V, Optional digital metering-IQ 250
Phase
Three-phase
Product Category
Switched Capacitor Banks
Voltage rating
480 V
Enclosure
Double-door enclosure unit
Frame size
L
Rating
700 kVAR
Step X kVAR
7 x 100 kVAR
Feature → Business Impact → Application: 700 kVAR rating and 840A amperage deliver meaningful PF correction, reducing demand charges and improving motor efficiency in facilities with large motor loads; Application: metal fabrication plants and continuous process lines seeking stable voltage. Feature → Business Impact → Application: 7 x 100 kVAR stepped banks enable staged correction as load varies, lowering oversizing risk and enabling smoother transitions during start-ups; Application: facilities with cyclic or peaking loads such as plastics and packaging lines. Feature → Business Impact → Application: 480 V three-phase operation and floor-mounted double-door enclosure simplify installation, service access, and safety compliance; Application: new builds or retrofits in industrial plants. Feature → Business Impact → Application: optional molded-case circuit breaker rated 65 kAIC at 480/600 V provides robust protection, reducing fault propagation and maintenance costs; Application: critical production lines requiring enhanced protection. Feature → Business Impact → Application: IQ 250 digital metering enables real-time monitoring and data-driven energy management, supporting audits and continuous improvement; Application: facilities pursuing ISO 50001 or electrical efficiency programs. Feature → Business Impact → Application: UL Listed, CSA Certified, UL 508A and UL 810 certifications deliver regulatory confidence, easing procurement and installation approvals; Application: compliance-driven projects across manufacturing and utilities.

Get a Quick Quote for a Eaton 700TPCSR431

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 700TPCSR431? Enquire Now

FAQs

The 700TPCSR431 ships with UL Listed and CSA Certified markings, and adheres to UL 508A and UL 810 standards. It is a floor-mounted, double-door enclosure designed for safe service access and straightforward installation in industrial spaces. For retrofit projects, ensure adequate floor space and forklift-accessible loading, with clearance for 78 inch height.
Key ratings include 840A amperage and 700 kVAR capacity at 480 V in a three-phase configuration. The unit features a floor-mounted enclosure with 7 x 100 kVAR steps, enabling staged correction. Optional MCCB protection up to 65 kAIC enhances fault protection, making it suitable for medium-to-large industrial drives and systems.
Yes. The 700TPCSR431 is designed for both new installations and retrofits. Its floor-mounted footprint and modular 7 x 100 kVAR steps support staged capacity additions as loads grow. Optional IQ 250 metering provides modern energy monitoring to align with existing energy management programs and retrofit timelines.
The unit carries UL Listed and CSA Certified marks, plus UL 508A and UL 810 compliance, ensuring electrical safety, control circuit reliability, and equipment protection. These certifications help with supplier qualification, code compliance, and installation approvals across manufacturing plants and utility-scale facilities.
Optional IQ 250 digital metering delivers real-time energy data, enabling proactive maintenance planning and energy-efficiency targeting. With a 700 kVAR rating and modular steps, you gain scalable capacity to match load growth, reducing penalties and extending asset life, supporting a faster return on investment in industrial environments.