Eaton 7063PMURN LV Unipak capacitor bank - UL Listed
Part Number: 7063PMURN
Quick Summary
The Eaton 7063PMURN LV Unipak capacitor bank provides reliable power factor correction for three-phase, low-voltage electrical systems. Many facilities struggle with rising energy costs and capacity constraints, especially when power factor correction is delayed or poorly implemented. CSA Certified and UL Listed certifications provide regulatory assurance, safety, and reliability for electrical installations across manufacturing floors and data centers. Designed as a rugged UNIPAK fixed-capacitor bank, it integrates with standard low voltage switchgear, helping engineers optimize efficiency, reduce penalties, and streamline maintenance planning. With a durable 14 gauge steel enclosure and powder-coat finish, it withstands demanding environments while maintaining consistent performance.
Product Information
Extended Description
7063PMURN Eaton: Eaton LV Unipak capacitor bank, UNIPAK, Low Voltage Fixed Capacitor Banks, 68.6A, 600V, Three-phase, 70 kVAR, Unprotected, Non-fused, 14 ga. steel finished with durable powder coat finish, C1 Frame
Product Name
Eaton LV Unipak capacitor bank
Catalog Number
7063PMURN
UPC
782116076383
Product Length/Depth
10.6 in
Product Height
26.3 in
Product Width
12.1 in
Product Weight
65 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
CSA Certified UL Listed
Catalog Notes
Multiply the 240V kVAR rating by 0.75 to calculate the kVAR value at 208V.
Type
UNIPAK
Amperage Rating
68.60A
Phase
Three-phase
Product Category
Low Voltage Fixed Capacitor Banks
Voltage rating
600 V
Enclosure
NEMA 1, NEMA 3R
Enclosure material
14 gauge steel finished with durable powder coat finish
Frame size
C1
Protection
Non-fused
Rating
70 kVAR
Eaton Specification Sheet - 7063PMURN
Selling Policy 25-000 - Distribution and Control Products and Services
Feature: UNIPAK architecture delivers compact, modular power factor correction for three-phase, 600 V systems. Business Impact: reduces reactive power demand, improving utility bills and energy efficiency. Application: ideal for manufacturing lines, commercial facilities, and data centers seeking reliable PF correction without complex wiring. Feature: rugged 14 gauge steel enclosure finished with durable powder coat and C1 frame provides long-term protection in harsh environments. Business Impact: minimizes maintenance and extends service life in dusty or moist plant areas. Application: indoor plant rooms and outdoor spaces requiring weather-resistant containment. Feature: non-fused protection and 68.60 A rating at 600 V for 70 kVAR enable straightforward integration with upstream protection and clear maintenance pathways. Business Impact: simplifies installation and reduces upfront wiring costs. Application: three-phase distribution panels and motor control centers in industrial settings. Feature: CSA Certified and UL Listed certifications deliver regulatory assurance and safety for critical operations; warranty policy supports long-term reliability. Business Impact: provides procurement confidence, reduces risk, and supports compliant asset management. Application: regulated industries and large-scale facilities with strict supplier requirements. Feature: catalog guidance notes voltage conversion from 240 V to 208 V by multiplying kVAR by 0.75; 240 V kVAR vs 208 V. Business Impact: enables accurate planning and sizing during design and retrofit, avoiding oversizing. Application: projects operating at different line voltages and in mixed-voltage environments.
Get a Quick Quote for a Eaton 7063PMURN
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 7063PMURN?
Enquire Now
FAQs
The unit fits a C1 UNIPAK frame with a 10.6 in depth, 26.3 in height, and 12.1 in width, weighing about 65 lb. It uses a NEMA 1 or NEMA 3R enclosure and is non-fused, requiring standard upstream protection. Plan for 600 V three-phase service and allocate space for wiring connections and clearance around a compact 70 kVAR bank to facilitate service and future maintenance.
The capacitor bank operates at 600 V, three-phase, with an amperage rating of 68.60 A and a reactive power rating of 70 kVAR. It is a UNIPAK low voltage fixed capacitor bank designed for fixed PF correction, unprotected and non-fused, with a 600 V rating and a 14 gauge steel enclosure.
Yes. The enclosure supports indoor and protected outdoor use via NEMA 1 and NEMA 3R ratings, enabling installation in varied plant environments while maintaining safety and performance.
The unit is CSA Certified and UL Listed, providing regulatory compliance and safety assurances for industrial deployments and procurement activities.
Warranty is Eaton Selling Policy 25-000: one year from installation or 18 months from shipment, whichever occurs first. Power factor correction reduces reactive power, lowering demand charges and energy costs, delivering measurable ROI over typical project lifetimes when properly sized and integrated.