Eaton LV Unipak capacitor bank 75243MVF3C - CSA
Part Number: 75243MVF3C
Quick Summary
Eaton LV Unipak capacitor bank provides compact, reliable power factor correction for three-phase industrial systems. Engineers often contend with limited space, heat buildup, and variable loads that complicate capacitor maintenance and switching. CSA certification reinforces safety and regulatory compliance for critical electrical upgrades in harsh plant environments. With a 75 KVAR rating at 2400 V and a fixed three-fuse configuration, this unit reduces energy waste, stabilizes voltage, and simplifies scheduled service. Designed for quick installation and enduring reliability, it scales from mid-size facilities to large manufacturing sites while integrating with standard switchgear footprints and existing protection schemes.
Product Information
Extended Description
75243MVF3C Eaton: Eaton 75 KVAR 2400V 3PH FIXED 3 FUSES CSA
Product Name
Eaton LV Unipak capacitor bank
Catalog Number
75243MVF3C
UPC
786685235448
Product Length/Depth
12.37 in
Product Height
34.44 in
Product Width
20.26 in
Product Weight
70 lb
Phase
Three-phase
75 KVAR capacity at 2400 V enables effective power factor correction across typical industrial loads, reducing reactive power and lowering utility demand charges. By delivering precise reactive compensation, the unit improves voltage stability at motors, pumps, and conveyors, boosting overall equipment efficiency. In real-world plants, the result is measurable energy savings and smoother operation during peak demand periods. This configuration is well-suited for mid-to-large facilities looking to balance performance with reliability. Three-phase configuration ensures balanced current among phases, minimizing neutral currents and reducing thermal stress on feeders and cables. This translates to longer component life and lower maintenance costs when supporting large drives or high-demand manufacturing lines. The three-phase approach also simplifies coordination with existing switchgear and protection schemes. Fixed three fuses provide robust, straightforward protection and eliminate field-fabricated fuse blocks, speeding installation and simplifying future servicing. CSA-based safety features support regulatory compliance, reducing commissioning risk in critical upgrades. With clear fault indication and standard wiring practices, maintenance teams can diagnose issues quickly and reduce downtime. Compact dimensions and weight—12.37 in depth, 20.26 in width, 34.44 in height, and 70 lb—fit within standard electrical rooms and panel housings. The unit’s footprint supports easy retrofits and scalable expansion without major rework. Its rigid enclosure and CSA-rated components withstand industrial dust, humidity, and temperature swings, contributing to longer service life. Access to Eaton’s specification sheet enhances engineering validation, procurement, and on-site installation planning. Integrated with common lugs and bus connections, it aligns with typical switchgear configurations and reduces field engineering time. Rugged construction and predictable performance make it a cost-effective choice for power factor correction projects. Business value is realized through reduced energy waste, improved motor performance, and faster project delivery for upgrades and expansions.
Get a Quick Quote for a Eaton 75243MVF3C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 75243MVF3C?
Enquire Now
FAQs
Installers should verify that the switchgear bus is rated for 2400 V and that the enclosure footprint accommodates 12.37 in depth, 20.26 in width, and 34.44 in height. Connect three-phase wiring to the capacitor assembly per Eaton’s specification sheet, ensuring proper fused protection. Use qualified electrical personnel and follow all CSA-related safety practices during mounting, wiring, and commissioning to minimize downtime.
75 KVAR indicates the reactive power the bank can supply to offset inductive loads at 2400 V. In practice, this enables significant power factor improvement for motors and drives, reducing reactive penalties and stabilizing voltage under peak load. Actual PF gain depends on site load profile, but sizing is suitable for mid-to-large industrial installations with substantial inductive demand.
Yes, the 75243MVF3C is designed for three-phase systems typical of manufacturing lines and can support data centers with high inductive loads. With its CSA-certified safety and robust fixed-fuse design, it integrates with standard switchgear and protects critical equipment while delivering reliable power factor correction and voltage stability in demanding environments.
This capacitor bank carries CSA certification, confirming compliance with safety and performance standards for electrical equipment used in industrial settings. CSA certification supports regulatory acceptance, reduces retrofit risk, and streamlines the commissioning process when upgrading power factor correction infrastructure.
Maintenance is streamlined by the fixed fuse configuration and CSA-rated design, reducing field-wiring adjustments and inspection time. ROI stems from energy savings from improved power factor, lower utility charges, and increased motor efficiency, which also translates to extended equipment life and reduced downtime during upgrades or retrofits.