Eaton 7X43PMURF Unipak Capacitor Bank - UL Listed

Part Number: 7X43PMURF
Manufacturer
Eaton
Part number
7X43PMURF

Quick Summary

Eaton LV Unipak capacitor bank is a low-voltage capacitor solution for power factor correction in three-phase electrical systems. Too many options can lead to underperforming reactive power management and costly downtime due to mis-sizing or protection conflicts. CSA Certified and UL Listed provide safety and compliance assurances, with rugged NEMA 1 and NEMA 3R enclosures for versatile environments. This solution offers reliable PF correction, efficient reactive power management, and straightforward installation within a compact A1 frame footprint. Designed for industrial control panels, it accommodates 480 V three-phase systems, provides 7.5 kVAR of reactive power, and includes three neon-blown fuse indicators protected by a weatherproof guard.

Product Information

Extended Description

7X43PMURF Eaton: Eaton LV Unipak capacitor bank, UNIPAK, Low Voltage Fixed Capacitor Banks, 9A, 480V, Three-phase, 7.5 kVAR, Protected, Neon red blown-fuse indicating lights, Three midget-type fuses, A1 Frame
Product Name
Eaton LV Unipak capacitor bank
Catalog Number
7X43PMURF
UPC
782116058617
Product Length/Depth
5.254 in
Product Height
17.3 in
Product Width
8.5 in
Product Weight
20 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
CSA Certified UL Listed
Catalog Notes
Multiply the 240V kVAR rating by 0.75 to calculate the kVAR value at 208V.
Type
UNIPAK
Amperage Rating
9A
Fuse type
Three midget-type fuses with 100,000 ampere interrupting capacity
Phase
Three-phase
Product Category
Low Voltage Fixed Capacitor Banks
Voltage rating
480 V
Enclosure
NEMA 1, NEMA 3R
Enclosure material
14 gauge steel finished with durable powder coat finish
Frame size
A1
Indicators
Red, neon blown-fuse indicating lights are protected by transparent weatherproof guard
Protection
Three fuses, three lights
Rating
7.5 kVAR
Feature: Compact A1 frame with 14 gauge steel and powder-coated finish. Business Impact: Enables easier installation in crowded control panels and improves long-term durability in harsh environments. Application: Panel-mounted power factor correction in 480 V three-phase systems. Feature: 7.5 kVAR rating at 480 V with a 9A current rating. Business Impact: Delivers precise reactive power compensation for motors and pumps while avoiding over-sizing, reducing energy losses and utility costs. Application: Industrial drives, conveyors, and HVAC systems seeking PF optimization. Feature: Three midget-type fuses with 100,000 ampere interrupting capacity and indicator lights. Business Impact: Enhances safety and maintenance through rapid fault indication and high fault-current protection. Application: Critical plant circuits where quick isolation is essential. Feature: Enclosure options NEMA 1 and NEMA 3R. Business Impact: Provides indoor protection and outdoor weather resistance, expanding site usability. Application: Panels in varied environments, from clean rooms to exposed outdoor installations. Feature: UL Listed and CSA Certified. Business Impact: Meets regulatory requirements and simplifies procurement with recognized safety credentials. Application: Any compliant facility seeking reliable third-party certification. Feature: Catalog notes for 208 V sizing (0.75 Ă— 240 V kVAR). Business Impact: Aids accurate selection and sizing across voltages, reducing misapplication risk. Application: Projects migrating or operating at 208 V systems while preserving reactive power performance.

Get a Quick Quote for a Eaton 7X43PMURF

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 7X43PMURF? Enquire Now

FAQs

Begin by mounting the UNIPAK unit on a suitable frame within a compliant enclosure. Connect per the wiring diagram to the 480 V three-phase supply, ensuring the 9A rating is not exceeded. Install the three midget-type fuses and verify the neon-blow fuse indicators are visible behind the weatherproof guard. Confirm enclosure is appropriately rated (NEMA 1 or NEMA 3R) and secure all(terminals) connections before power-up.
Verify 480 V operation, three-phase configuration, and a 7.5 kVAR rating with a 9A current draw. Check enclosure suitability (NEMA 1 or NEMA 3R), frame size A1, and three fuses with 100,000 AIC. Use the catalog note to adjust kVAR for 208 V applications by multiplying the 240 V kVAR value by 0.75.
Yes. The 7X43PMURF Unipak delivers fixed reactive power in a three-phase 480 V setting, optimizing PF for motor drives, pumps, and conveyors. Benefits include reduced line losses, improved voltage profile, and enhanced equipment efficiency. Ensure proper coordination with existing reactive power sources and protective devices to avoid overcompensation.
The unit is UL Listed and CSA Certified, affirming compliance with safety and performance standards. These certifications facilitate regulatory approvals, supplier qualification, and safer maintenance practices in industrial facilities, while providing confidence in electrical isolation, enclosure integrity, and fuse protection essential for robust operation.
Maintenance is straightforward thanks to the neon indicators that signal blown fuses and the rugged powder-coated enclosure. The 1-year warranty (or 18 months from shipment) supports initial ROI, while energy savings from improved PF reduce utility bills and extend motor life. Regular inspection of fuses and indicators helps sustain performance and minimize unplanned downtime.