Eaton 800TPCSR431M Switched Capacitor Banks - UL Listed
Part Number: 800TPCSR431M
Quick Summary
Eaton LV AutoVAR 600 capacitor bank provides compact reactive power management for industrial electrical systems. Facilities often struggle with rising energy costs and voltage flicker as motor starts impose peak demand, making capacitor banks essential for PF correction. UL Listed and CSA Certified, the unit’s rugged NEMA 1, powder-coated enclosure and integrated main breaker support safe, compliant operation in busy plant environments. The 800 kVAR rating paired with 8 x 100 kVAR steps offers precise tuning for varying loads, enabling scalable PF improvement across manufacturing lines. By aligning with procurement and maintenance goals, this solution reduces energy penalties while simplifying installation and service in floor-mounted configurations.
Product Information
Extended Description
800TPCSR431M Eaton: Eaton AUTOVAR 600, Switched Capacitor Banks, 960A, 480V, Three-phase, 800 kVAR, Floor-mounted, Double-Door Enclosure Unit, 8 x 100, KK Frame, Main Breaker
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
800TPCSR431M
UPC
786689282110
Product Length/Depth
26 in
Product Height
78 in
Product Width
79 in
Product Weight
1704 lb
Certifications
UL Listed CSA Certified
Type
AUTOVAR 600
Accessories
molded-case circuit breaker rated 65 kAIC
Amperage Rating
960A
Frequency rating
60 Hz
Mounting
Floor
Phase
Three-phase
Product Category
Switched Capacitor Banks
Voltage rating
480 V
Enclosure
NEMA 1
Enclosure material
Powder coated carbon steel
Enclosure size
KK
Rating
800 kVAR
Step X kVAR
8 x 100 kVAR
The 800 kVAR rating with a 960 A current capability and 60 Hz operation provides robust reactive power support for 480 V three-phase systems, enabling effective PF correction that reduces demand charges and improves voltage stability across motors and drives. This translates into tangible business outcomes by lowering utility penalties and extending equipment life through smoother power delivery. With 8 x 100 kVAR steps, the system offers granular tuning to adapt to changing load profiles, helping packaging lines, HVAC groups, and processing equipment achieve optimal energy efficiency and faster commissioning.
Get a Quick Quote for a Eaton 800TPCSR431M
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 800TPCSR431M?
Enquire Now
FAQs
Installation requires adequate floor space for a floor-mounted NEMA 1 enclosure, with a 26 in depth, 78 in height, and 79 in width providing enough room for safe access. The unit includes a main breaker and molded-case breaker rated at 65 kAIC, facilitating straightforward integration with existing 480 V three-phase bus configurations. Plan clearances, mechanical mounting, and wiring routes before energization to minimize downtime and ensure compliance with UL CSA certifications.
Core specs include an 800 kVAR rating, 960 A Amperage, 480 V voltage, three-phase operation, and 60 Hz frequency. It features 8 x 100 kVAR stepping for granular PF correction, a NEMA 1 powder-coated carbon steel enclosure, and a floor-mounted KK frame. The unit is UL Listed and CSA Certified, with an integrated main breaker and a molded-case breaker rated at 65 kAIC for protection.
Yes. Its 800 kVAR capacity with 8 x 100 kVAR steps supports diverse loads typical of manufacturing lines, conveyors, pumps, and large HVAC systems. The floor-mounted design and robust enclosure facilitate installation in plant environments, while UL CSA certification provides regulatory confidence. The 480 V three-phase rating matches standard industrial power distribution, making it a versatile PF correction solution.
The Eaton 800TPCSR431M is UL Listed and CSA Certified, indicating compliance with major safety and performance standards. The NEMA 1 enclosure supports protection in typical industrial environments, and the integrated main breaker simplifies electrical protection during commissioning and maintenance. These certifications aid procurement and reduce risk in regulated industries.
The PF correction provided by the 800 kVAR bank lowers energy penalties and improves equipment efficiency, contributing to a favorable ROI over time. Maintenance is streamlined by the integrated protection (main breaker and 65 kAIC MCCB) and access-friendly NEMA 1 enclosure. Routine checks focus on capacitor bank insulation, polarity, and breaker functionality to sustain reliability in manufacturing plants.