Quick Summary
Eaton LV AutoVAR 600 capacitor bank provides targeted reactive power correction for low-voltage, three-phase Power networks. A common challenge is energy waste and equipment stress from poor power factor, which this bank mitigates. UL Listed and CSA Certified ensure safety and compliance across industrial sites, while 480 V and 60 Hz specs match standard facilities. Used with AUTOVAR 600, this solution scales PF correction, reduces energy costs, and supports reliable operation of critical loads. It features eight 100 kVAR steps, a floor-mounted NEMA 3R enclosure, fuse protection, and compatibility with the AUTOVAR 600 family for modular expansion. This design prioritizes installability and serviceability in busy facilities, with heavy-duty capacitor cells for long life.
Product Information
Extended Description
800TPHSR431M Eaton: AUTOVAR 600 Switched Capacitor Bank, 462A, 800 kVAR, 8 x 100 step, 480V rating, 60 Hz, Three-phase, Heavy-duty capacitor cells, Floor-mount, KK sized NEMA 1 enclosure, Fused, Low voltage applications, Main Breaker
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
800TPHSR431M
UPC
786689282226
Product Length/Depth
29 in
Product Height
80 in
Product Width
80.4 in
Product Weight
1784 lb
Certifications
UL Listed CSA Certified
Type
Switched Capacitor Bank
Amperage Rating
462A
Frequency rating
60 Hz
Options
Heavy duty capacitor cells, NEMA 3R enclosure
Phase
Three-phase
Voltage rating
480 V
Mounting
Floor
Used with
AUTOVAR 600
Application
Low voltage
Enclosure
NEMA 3R
Enclosure size
KK
kVA rating
800 kVAR
Protection
Fuses
Step X kVAR
8 x 100 kVAR
Feature: Heavy-duty capacitor cells with fused protection deliver reliable, safe operation in demanding environments. Business Impact: Minimizes unexpected downtime and protects downstream equipment from PF swings, improving motor efficiency and reducing energy waste. Application: Ideal for low-voltage capacitor bank deployments on manufacturing lines and HVAC systems. Feature: Eight 100 kVAR steps with a 462 A rating enable scalable reactive power correction. Business Impact: Matches load growth and seasonal variations, lowering peak demand charges and extending capacitor life. Application: Suitable for facilities with fluctuating loads and varying process demands. Feature: NEMA 3R floor-mount enclosure and KK sized housing provide rugged, space-efficient installation. Business Impact: Simplifies on-site integration, reduces installation time, and enhances indoor/outdoor suitability. Application: Factory floors and service corridors where space is at a premium. Feature: Compatibility with AUTOVAR 600 offers a clear upgrade path and modular expansion. Business Impact: Protects capital investment while enabling gradual capacity increases. Application: Buildings and plants planning PF improvements across multiple stages. Feature: UL Listed and CSA Certified markings ensure regulatory compliance and safer procurement. Business Impact: Eases audits, vendor qualification, and maintenance planning. Application: Industrial facilities with strict safety standards. Feature: 480 V, 60 Hz three-phase ratings align with common industrial distributions. Business Impact: Reduces engineering changes during integration and accelerates project timelines. Application: Data centers, process lines, and large machinery in low-voltage networks.
Get a Quick Quote for a Eaton 800TPHSR431M
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 800TPHSR431M?
Enquire Now
FAQs
Install as a floor-mounted unit in a protected area using the NEMA 3R enclosure. Ensure proper clearances for cooling and access to fuse protection and main breaker. Verify compatibility with AUTOVAR 600 and connect to a 480 V, three-phase distribution. Follow the manufacturer’s installation instructions and local electrical codes for safe, compliant operation.
The unit provides 462 A amperage, 800 kVAR kVAR rating, operates at 480 V, 60 Hz in a three-phase configuration, and features 8 x 100 kVAR stepping. It uses fuses for protection and is designed for low-voltage reactive power correction in industrial facilities.
Yes. With 480 V three-phase operation, 800 kVAR capacity, and eight 100 kVAR steps, the 800TPHSR431M is designed for PF correction in manufacturing environments. It integrates with AUTOVAR 600 for scalable capacity and helps reduce energy costs while protecting equipment from PF-related stress.
The unit is UL Listed and CSA Certified, providing safety and compliance assurances for industrial procurement. These certifications support regulatory acceptance and simplify safety audits during site qualification and commissioning.
Plan periodic inspections of fuse protection and capacitor cells, monitor for vibration and heat, and verify connections to the main breaker. The modular eight-step design facilitates phased maintenance and future upgrades within AUTOVAR 600 ecosystems, helping sustain PF correction performance and extend overall system life.