Eaton 800TPHSR631M Switched Capacitor Bank - UL Listed

Part Number: 800TPHSR631M
Manufacturer
Eaton
Part number
800TPHSR631M

Quick Summary

Eaton LV AutoVAR 600 capacitor bank is a switched-capacitor bank for low-voltage power factor correction in three-phase industrial systems. Facilities struggle with rising demand charges and harmonics, making commissioning and maintenance costly; this solution reduces both through precise VAR stepping and robust protection. Two critical certifications—UL Listed and CSA Certified—back safety, reliability, and compliance in North American markets. Designed for low-voltage applications with a floor-mounted KK enclosure, it actively reduces energy costs while staying serviceable and compliant during routine maintenance. By integrating the main breaker option and AUTOVAR 600 compatibility, procurement is streamlined and installation time is reduced, delivering tangible business value to industrial plants.

Product Information

Extended Description

800TPHSR631M Eaton: AUTOVAR 600 Switched Capacitor Bank, 768A, 800 kVAR, 8 x 100 step, 600V rating, 60 Hz, Three-phase, Heavy-duty capacitor cells, Floor-mount, KK sized NEMA 1 enclosure, Fused, Low voltage applications, with Integrated main breaker
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
800TPHSR631M
UPC
786685992426
Product Length/Depth
29 in
Product Height
80 in
Product Width
41.3 in
Product Weight
1814 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed CSA Certified
Type
Switched Capacitor Bank
Amperage Rating
768A
Frequency rating
60 Hz
Options
Integrated main breaker
Phase
Three-phase
Voltage rating
600 V
Mounting
Floor
Used with
AUTOVAR 600
Application
Low voltage
Enclosure
NEMA 1
Enclosure size
KK
kVA rating
800 kVAR
Protection
Fuses
Step X kVAR
8 x 100 kVAR
Feature: High-current 768 A, 800 kVAR switched capacitor bank with 8 x 100 kVAR steps enables precise VAR control; Business Impact: Enables staged correction that adapts to load swings, lowers peak demand, and reduces utility charges; Application: Ideal for indoor, low-voltage, three-phase facilities seeking reliable power quality. Feature: Integrated main breaker option simplifies electrical installation and commissioning; Business Impact: Reduces panel space, wiring complexity, and startup time; Application: Retrofit projects and new builds requiring compact, safer protection. Feature: Floor-mounted, NEMA 1 KK enclosure with heavy-duty capacitor cells and fuse protection; Business Impact: Enhances safety, serviceability, and durability in demanding industrial environments; Application: Manufacturing floors and distribution centers. Feature: 600 V, 60 Hz three-phase design with AUTOVAR 600 compatibility; Business Impact: Ensures broad compatibility with existing plant equipment and scalable expansion; Application: Automotive, metal, and process facilities powered by standard grids. Feature: Robust protection and warranty support; Business Impact: Improves uptime and total cost of ownership; Application: Plants prioritizing reliability and predictable maintenance.

Get a Quick Quote for a Eaton 800TPHSR631M

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 800TPHSR631M? Enquire Now

FAQs

The 800TPHSR631M is designed as a floor-mounted, three-phase capacitor bank that works with Eaton's AUTOVAR 600 system. It uses 8 x 100 kVAR steps, 600 V, 60 Hz, and can include an integrated main breaker for simplified integration in low-voltage applications.
The unit delivers 800 kVAR at 600 V with a 768 A rating, configured as eight 100 kVAR steps. This stepping supports staged correction, enabling precise control over load variation and improved energy cost management.
This capacitor bank is UL Listed and CSA Certified, confirming adherence to key electrical safety standards for North American installations and regulatory compliance in industrial environments.
Floor mounting in a KK NEMA 1 enclosure and optional integrated main breaker simplify installation, reduce wiring, and speed up commissioning. The rugged enclosure and fuse protection support reliable operation in busy plant environments.
Ideal for low-voltage, three-phase industrial networks seeking power factor correction and demand reduction. It suits manufacturing lines, pumps, and compressors, with gradual VAR stepping to minimize voltage dips and harmonics while improving overall equipment efficiency.