Eaton 800TPHSR631MW LV AutoVAR - UL Listed, CSA Certified
Part Number: 800TPHSR631MW
Quick Summary
Eaton LV AutoVAR 600 capacitor bank delivers high-capacity reactive power support for low-voltage, three-phase systems. Facility teams routinely confront downtime and wiring complexity when expanding capacitor banks, making quick installation and reliable protection essential. This unit carries UL Listed and CSA Certified marks, and it uses a rugged NEMA 3R, KK enclosure to withstand demanding factory floor conditions. The integrated main breaker simplifies commissioning and enhances fault containment, helping reduce maintenance events. With scalable 8 x 100 kVAR steps and a 600 V rating, it supports efficient power factor correction across diverse loads, while remaining compatible with the AUTOVAR 600 family. In short, it combines safety, reliability, and cost efficiency for industrial buyers.
Product Information
Extended Description
800TPHSR631MW Eaton: AUTOVAR 600 Switched Capacitor Bank, 768A, 800 kVAR, 8 x 100 step, 600V rating, 60 Hz, Three-phase, Heavy-duty capacitor cells, Floor-mount, KK sized NEMA 3R enclosure, Fused, Low voltage applications, with Integrated main breaker
Product Name
Eaton LV AutoVAR 600 capacitor bank
Catalog Number
800TPHSR631MW
UPC
786685993041
Product Length/Depth
29 in
Product Height
80 in
Product Width
80.4 in
Product Weight
1834 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed CSA Certified
Type
Switched Capacitor Bank
Amperage Rating
768A
Frequency rating
60 Hz
Options
Integrated main breaker
Phase
Three-phase
Voltage rating
600 V
Mounting
Floor
Used with
AUTOVAR 600
Application
Low voltage
Enclosure
NEMA 3R
Enclosure size
KK
kVA rating
800 kVAR
Protection
Fuses
Step X kVAR
8 x 100 kVAR
The 800 kVAR Switched Capacitor Bank provides robust reactive power support for low-voltage, three-phase systems, delivering 768A of current with eight 100 kVAR steps. This granular step sizing translates into precise power factor correction, reduced distribution losses, and improved motor efficiency, ultimately lowering energy costs for facilities with heavy motor loads and varying demand. By leveraging a floor-mounted KK enclosure and a 600 V, 60 Hz rating, it offers installation flexibility and compatibility with standard industrial distributions, enabling quick deployment in new builds or upgrades without rework on the existing switchgear. Integrated protection through fuses and a main breaker minimizes external components, reduces fault exposure, and shortens maintenance windows during commissioning or servicing. The unit’s NEMA 3R enclosure supports durable use in challenging environments, while UL Listed and CSA Certified marks simplify procurement and regulatory compliance. Compatibility with AUTOVAR 600 families ensures scalable upgrades as facility loads evolve, delivering predictable, repeatable performance with proven industry standardization. This combination of rugged build, precise kVAR stepping, and integrated protection translates into measurable ROI through improved power factor, reduced peak demand, and lower total cost of ownership for industrial operators.
Get a Quick Quote for a Eaton 800TPHSR631MW
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton 800TPHSR631MW?
Enquire Now
FAQs
The unit is floor-mounted with a KK sized NEMA 3R enclosure, designed for robust on-site use. It weighs about 1834 lb and requires space for the 29 in depth, 80 in height, and 80.4 in width, plus access for wiring to the integrated main breaker and fuse protection. This configuration supports straightforward installation alongside existing AUTOVAR 600 systems and standard low-voltage switchgear. Ensure proper clearances, grounding, and compliance with local codes during commissioning.
Key specs include a 768A amperage rating, 800 kVAR kVA rating, 600 V voltage rating, and 60 Hz frequency. It features 8 x 100 kVAR steps, three-phase operation, fused protection, and an option for an integrated main breaker. The product is designed for low-voltage applications and is compatible with AUTOVAR 600 systems, making it suitable for scalable reactive power control in industrial facilities.
Yes. The 800TPHSR631MW is explicitly rated for low-voltage, three-phase distribution with a 600 V rating and 60 Hz. Its design, including the integrated main breaker and fused protection, supports reliable operation in manufacturing environments where precise power factor correction and maintenance-friendly protection are critical.
The unit is UL Listed and CSA Certified, providing safety and electrical standard compliance for industrial installations. These marks help simplify procurement and regulatory acceptance. The enclosure also adheres to rugged NEMA 3R ratings, which supports durable operation on factory floors.
The integrated main breaker simplifies fault isolation, reduces the number of external components, and shortens commissioning and maintenance cycles. This leads to lower downtime, faster troubleshooting, and reduced total cost of ownership, especially in facilities with variable loads and frequent reactive power adjustments.