Eaton 900THFSR432MY LV AutoVAR filter - UL Listed & CSA Certified

Part Number: 900THFSR432MY
Manufacturer
Eaton
Part number
900THFSR432MY

Quick Summary

Eaton LV AutoVAR filter 900THFSR432MY delivers automatic capacitor bank control to optimize reactive power on 3‑phase 480 V systems in industrial facilities. This solution helps reduce energy waste and voltage flicker by automatically switching capacitor banks as load conditions change, minimizing manual intervention. The unit carries UL Listed and CSA Certified safety credentials, supported by a rugged NEMA 1 enclosure and floor-mounted KK+KK frame design. With 60 Hz operation and a 900 kVAR rating, it integrates into standard plant distributions while delivering tangible savings and reliability. For procurement teams, the combination of certified safety, robust construction, and scalable capacity supports faster approvals and long-term operating cost reductions.

Product Information

Extended Description

900THFSR432MY Eaton: Eaton AUTOVAR Filter, Automatic Capacitor Banks, 4.2 Detuned Reactors, 480V, 900 kVAR, Floor-mounted, 9 x 100, KK+KK Frame, NEMA 1, Main Breaker
Product Name
Eaton LV AutoVAR filter
Catalog Number
900THFSR432MY
UPC
786689282141
Product Length/Depth
180 in
Product Height
86 in
Product Width
38 in
Product Weight
3900 lb
Certifications
UL Listed CSA Certified
Type
AUTOVAR Filter
Accessories
molded-case circuit breaker rated 65 kAIC
Frequency rating
60 Hz
Mounting
Floor
Phase
Three-phase
Product Category
Switched Capacitor Banks
Tuning
4.2H
Voltage rating
480 V
Enclosure
NEMA 1
Enclosure material
Powder coated carbon steel
Enclosure size
KK + KK
Rating
900 kVAR
Step X kVAR
9 x 100 kVAR
Feature → Business Impact → Application: Automatic AutoVAR control reduces manual switching and operator intervention, lowering maintenance costs and improving reliability in continuous‑duty plants. Application: large manufacturing lines and processing facilities where reactive power fluctuates with motor loads. Feature → Business Impact → Application: 9 x 100 kVAR stepping (900 kVAR total) provides scalable reactive power correction, enabling precise PF targets and reduced utility penalties. Application: OEMs and end users with variable motor loads and multiple drives. Feature → Business Impact → Application: 4.2H detuned reactors limit harmonic currents and protect sensitive equipment, improving power quality and reducing nuisance trips. Application: facilities with VFDs and high harmonic content. Feature → Business Impact → Application: Floor-mounted, NEMA 1, powder-coated carbon steel enclosure delivers rugged durability on the plant floor. Application: manufacturing, packaging, and process environments requiring reliable installation. Feature → Business Impact → Application: KK+KK frame and 60 Hz, 480 V three‑phase compatibility simplify integration with existing switchgear and bus systems. Application: retrofit projects and new builds with standard plant voltages. Feature → Business Impact → Application: Accessory compatibility with molded‑case circuit breaker rated 65 kAIC enables coordinated protection and selective coordination. Application: electrical distribution designs prioritizing safety and fault containment. Feature → Business Impact → Application: UL Listed and CSA Certified compliance reduces risk in audits and procurement, accelerating project sign-off. Application: regulated industries and service providers seeking proven safety credentials.

Get a Quick Quote for a Eaton 900THFSR432MY

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 900THFSR432MY? Enquire Now

FAQs

The unit is floor-mounted in a 3‑phase 480 V system with a KK+KK frame and a NEMA 1 enclosure. Plan for adequate floor space, access for wiring and breakers, and alignment with existing switchgear. Ensure compatibility with molded-case breakers rated 65 kAIC and proper clearance for maintenance access.
It automatically tunes reactive power via 9 x 100 kVAR steps (900 kVAR total) and 4.2H tuning, reducing VAR demand, lowering current, and stabilizing voltage. This results in fewer utility penalties, improved motor efficiency, and enhanced system reliability without frequent manual intervention.
Yes. The filter is designed to integrate with molded-case circuit breakers rated at 65 kAIC, enabling proper coordination and protection. This compatibility supports straightforward retrofits and ensures safe, orderly fault isolation within standard plant distributions.
The unit carries UL Listed and CSA Certified markings, confirming compliance with recognized electrical safety standards. While not listed here, verify any additional regional requirements (such as CE or IP ratings) for your specific project scope and facility.
ROI comes from reduced reactive power charges, lower line current, and improved equipment efficiency. While exact payback varies by site load profile and tariff, the automatic control, high-capacity 900 kVAR bank, and durable on-floor installation typically yield measurable annual savings and quicker procurement cycles through certified safety and compatibility.