Eaton 9063PMURF UNIPAK Capacitor Bank - UL Listed

Part Number: 9063PMURF
Manufacturer
Eaton
Part number
9063PMURF

Quick Summary

Eaton LV Unipak capacitor bank provides reliable reactive power support for three-phase industrial motor systems. In compact spaces with frequent voltage fluctuations, undersized banks can cause voltage drop and overheating. Certified UL Listed and CSA Certified, the unit adheres to modern safety and performance standards, with NEMA 1/3R enclosures. Designed as a low voltage fixed capacitor bank, it supports power-factor correction and improves energy efficiency across industrial power systems. Its robust frame and protective fuses streamline installation, upgrade projects, and ongoing maintenance, helping you meet regulatory requirements while reducing downtime and energy costs. With UL Listed and CSA Certified assurance, this unit supports audits, safer commissioning, and scalable upgrades.

Product Information

Extended Description

9063PMURF Eaton: Eaton LV Unipak capacitor bank, UNIPAK, Low Voltage Fixed Capacitor Banks, 88.2A, 600V, Three-phase, 90 kVAR, Protected, Neon red blown-fuse indicating lights, Three slottedblade-type fuses, C1 Frame
Product Name
Eaton LV Unipak capacitor bank
Catalog Number
9063PMURF
UPC
782116059317
Product Length/Depth
10.6 in
Product Height
26.3 in
Product Width
12.1 in
Product Weight
68 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed CSA Certified
Catalog Notes
Multiply the 240V kVAR rating by 0.75 to calculate the kVAR value at 208V.
Type
UNIPAK
Amperage Rating
88.20A
Fuse type
Three slottedblade type fuses with 200,000 ampere interrupting capacity
Phase
Three-phase
Product Category
Low Voltage Fixed Capacitor Banks
Voltage rating
600 V
Enclosure
NEMA 1, NEMA 3R
Enclosure material
14 gauge steel finished with durable powder coat finish
Frame size
C1
Indicators
Red, neon blown-fuse indicating lights are protected by transparent weatherproof guard
Protection
Three fuses, three lights
Rating
90 kVAR
Feature → Business Impact → Application: The UNIPAK three-phase design integrates the capacitor bank into a compact assembly, reducing panel space and simplifying wiring during PF correction projects. This translates into shorter installation times, lower field labor costs, and quicker commissioning. Application: Ideal for motor drives, compressors, and HVAC loads in manufacturing facilities seeking stable voltage profiles and measurable energy savings across their power systems. Feature → Business Impact → Application: The 600 V rating with an 88.2 A current rating and a 90 kVAR output provides precise reactive power support for common low-voltage feeders. Impact: minimizes voltage drop, lowers utility penalties, and improves capacity for peak loads. Application: Suitable for control panels and distribution boards in robotics, packaging lines, and process plants. Feature → Business Impact → Application: The enclosure is NEMA 1 and NEMA 3R, with 14 gauge steel and durable powder coating, delivering rugged protection in indoor and outdoor installations. Impact: extended service life and reduced corrosion-related downtime. Application: Install in machine rooms, outdoor equipment bays, or near switchgear cabinets with minimal environmental constraints. Feature → Business Impact → Application: Protection includes three fuses with three neon indicators protected by a weatherproof guard, offering fast fault identification and safe maintenance. Impact: lowers repair time and improves operator safety. Application: Field servicing and routine checks where quick visual status helps maintenance teams respond promptly. Feature → Business Impact → Application: Comprehensive documentation and compliance are supported by UL Listed and CSA Certified status, plus a detailed specification sheet and warranty policy. Impact: simplifies audits, procurement, and post-sale service, while reducing total cost of ownership. Application: OEMs, energy managers, and reliability teams implementing PF correction programs.

Get a Quick Quote for a Eaton 9063PMURF

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton 9063PMURF? Enquire Now

FAQs

Installers should verify three-phase 600 V supply compatibility and ensure proper clearance around the unit for heat dissipation. The enclosure is NEMA 1 and NEMA 3R, with a 14 gauge steel frame (C1) and overall footprint of 10.6 in L, 12.1 in W, 26.3 in H. Use three slottedblade fuses (200kAIC) and observe the 240 V kVAR note for 208 V operation.
Key specs include a 90 kVAR rating, 88.20 A amperage, 600 V voltage rating, three-phase configuration, UNIPAK type, frame size C1, and enclosure NEMA 1/NEMA 3R. It includes three fuses with 200,000 AIC, red neon indicators, and a protected fault-detection system to enhance safety during maintenance.
Yes. With a 90 kVAR rating and 600 V operation, it provides targeted reactive power support for common industrial loads such as motors and drives, improving power factor and reducing energy costs. The UNIPAK design simplifies integration, and the protective features help maintain reliability in demanding manufacturing environments.
The unit is UL Listed and CSA Certified, signaling compliance with safety and performance standards. These certifications aid audits, simplify procurement decisions, and support safe commissioning. The warranty (one year from installation or 18 months from shipment) further assures ongoing field reliability.
Maintenance benefits include visible fuse status via neon indicators and robust fusing protection, which reduce downtime and speed fault response. ROI improves through power-factor correction, energy savings, and extended equipment life. The unit’s rugged enclosure and warranty terms help lower total cost of ownership in continuous operation environments.