Eaton APSD42870 Linear Fluorescent Fixture - IP66

Part Number: APSD42870
Manufacturer
Eaton
Part number
APSD42870

Quick Summary

The Eaton APSD42870 Linear Fluorescent Fixture delivers reliable illumination for hazardous locations in industrial facilities. In these environments, persistent glare, corrosion, and maintenance downtimes erode safety and productivity; a robust solution is essential. This fixture carries Hazardous/Classified Locations ratings, IP66 ingress protection, and a NEMA 4X rugged housing, ensuring performance under tough conditions. With a 2-lamp, 4 ft configuration operating on 120–277 VAC at 50/60 Hz and a 48 W draw, it integrates seamlessly into standard installations and existing Pauluhn AllPro line. The result is safer, compliant lighting that reduces downtime and simplifies ongoing maintenance while enabling efficient operations in demanding environments.

Product Information

Extended Description

APSD42870 Eaton: Eaton’s Crouse-Hinds series Pauluhn AllPro APS linear fluorescent light fixture,3/4" entry ,50/60 Hz,4 ft lamp,Fluorescent,Drop,Acrylic lens,T12HO RDC,304 stainless steel,2-lamp,Standard wall/ceiling,120-277 Vac,48W
Product Name
Eaton Crouse-Hinds series Pauluhn AllPro APS linear fluorescent light fixture
Catalog Number
APSD42870
UPC
662276389120
Product Length/Depth
55.5 in
Product Height
9 in
Product Width
9.75 in
Product Weight
34 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 1 Class III
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lamp type
Fluorescent
Lens type
Drop
Material
304 stainless steel
Lamp length
4 ft
Number of lamps
2-lamp
Light type
T12HO RDC
Voltage rating
120-277 Vac
Frequency rating
50/60 Hz
Mounting
Standard wall/ceiling
Entry size
3/4"
Wattage
48W
Lens material
Acrylic
Feature → Business Impact → Application: 304 stainless steel housing provides exceptional corrosion resistance, extending service life in washdown and chemical exposure areas, reducing replacement intervals and total cost of ownership for offshore platforms and chemical plants; Applied in hazardous locations, the IP66 and NEMA 4X ratings help ensure safety and compliance in marine terminals and petrochemical facilities. Feature → Business Impact → Application: Drop, acrylic lens minimizes glare and protects the lamp chemistry from dust and splashes, improving worker comfort and visibility in cramped utility rooms and maintenance corridors. Feature → Business Impact → Application: 3/4" entry and standard wall/ceiling mounting simplify retrofits and new installs, enabling quick, outage-minimized upgrades in manufacturing floors and processing plants. Feature → Business Impact → Application: 4 ft lamp length with 2 lamps and 48 W power draw balances illumination quality with energy efficiency, supporting lower operating costs in long-run process basements and water treatment facilities. Feature → Business Impact → Application: 120–277 VAC, 50/60 Hz compatibility ensures broad electrical compatibility across facilities, reducing the need for transformers and reducing installation complexity in mixed-use campuses. Feature → Business Impact → Application: NEC/CEC compliance and Hazardous/Classified Locations rating deliver regulatory assurance for compliant design reviews, reducing risk during audits and commissioning of new sites.

Get a Quick Quote for a Eaton APSD42870

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton APSD42870? Enquire Now

FAQs

APSD42870 supports standard wall/ceiling mounting with a 3/4" entry for conduit connections. Verify conduit suitability by ensuring enclosure rating and wiring methods comply with NEC/CEC for Class I, II, III environments. Use listed wiring methods and seal where applicable to maintain IP66 protection. Pre-install checks should include lamp type and ballast compatibility for T12HO RDC lamps.
The fixture is rated for Hazardous/Classified Locations with NEC/CEC standards compliance, offering Class I Division 2, Class II Division 1, and Class III suitability. IP66 ingress protection and NEMA 4X construction provide rugged protection against dust, water jets, and corrosion, making it appropriate for chemical processing, oil and gas, and similar industrial settings.
Yes, the APSD42870 uses standard wall/ceiling mounting and a 3/4" entry, enabling straightforward retrofits or new installs. Its 55.5 in length, 9 in height, and 9.75 in width align with common 4 ft class fixtures, reducing field adaptations and shortening commissioning time in industrial facilities.
Key references include Hazardous/Classified Locations ratings, NEC/CEC standards, IP66 ingress protection, and NEMA 4X enclosure. These specify suitability for hazardous environments and washdown-ready operation, helping meet regulatory requirements and pass routine safety and insurance audits.
With 2-lamp 48W operation and 55.5 in length, the fixture provides bright, even illumination with relatively low energy use. The 304 stainless steel housing and acrylic lens resist corrosion and dirt, reducing cleaning and replacement frequency. Lifecycle cost is improved through longer intervals between maintenance, lower downtime, and compatibility with existing Pauluhn AllPro components.