Eaton B222-60FGFST Air Conditioning Disconnect - UL Listed
Part Number: B222-60FGFST
Quick Summary
The Eaton air conditioning disconnect is a rugged, code-compliant solution for outdoor HVAC installations. It addresses common challenges such as weatherproof protection, accurate wiring, and safe isolation to minimize unplanned downtime. UL Listed, NEMA 3R enclosure, and a 10 kAIC interrupt rating ensure reliable performance in harsh outdoor environments. With a fused pullout design and 60A capacity, it enables quick maintenance and safer service for 120/240V systems. This disconnect is well-suited for commercial and residential HVAC applications, delivering dependable protection while integrating with standard wiring and field install practices.
Product Information
Extended Description
B222-60FGFST Eaton: Eaton air conditioning disconnect, Bussmann series 60A Fusible GFCI, 120/240V, 60A, 10 kAIC, Fused pullout, NEMA 3R, ANSI 61 gray
Product Name
Eaton air conditioning disconnect
Catalog Number
B222-60FGFST
UPC
786685982281
Product Length/Depth
0.01 in
Product Height
0.01 in
Product Width
0.01 in
Product Weight
0.01 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Type
Fused pullout
Amperage Rating
60A
Voltage rating
120/240 V
Wire size
#14-3 AWG Cu/Al
Color
ANSI 61 gray
Enclosure
NEMA 3R
Enclosure material
Galvanized steel
Interrupt rating
10 kAIC
Receptacle
15 A ground fault self-test receptacle
Residential and Light Commercial, Air Conditioning Disconnects, Volume 1 Tab 6
Residential and Light Commercial, Air Conditioning Disconnects, Volume 1 Tab 6
Eaton Specification Sheet - B222-60FGFST
Bussmann series Fused and non-fused HVAC disconnects data sheet no. 1143
Feature → Business Impact → Application: The 60A fused pullout with a ground fault self-test receptacle provides safe, code-compliant isolation and nuisance fault protection, reducing the risk of arc flash during servicing and enabling quick fault location in rooftop units and outdoor condensers. This directly supports uptime and maintenance efficiency in commercial HVAC deployments. Feature → Business Impact → Application: A NEMA 3R galvanized steel enclosure delivers durable, weatherproof protection against rain, dust, and corrosion, extending service life for outdoor installations on rooftops and exterior equipment pads. This enclosure choice lowers replacement costs and improves long-term reliability. Feature → Business Impact → Application: With UL Listed status, 10 kAIC interrupt rating, and 120/240V operation, the device aligns with electrical codes and supports safe, scalable wiring for HVAC circuits and outdoor disconnects. Feature → Business Impact → Application: Wire sizing support for #14-3 AWG Cu/Al enables straightforward integration with standard field wiring, reducing fabrication time and enabling faster project completion. Feature → Business Impact → Application: The 15 A ground fault self-test receptacle enhances safety and simplifies ongoing testing, reducing preventive maintenance time and ensuring continuous circuit protection. Feature → Business Impact → Application: The Eaton warranty policy (25-000) provides assurance for installation teams and procurement budgets, supporting lifecycle planning and total cost of ownership reductions.
Get a Quick Quote for a Eaton B222-60FGFST
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton B222-60FGFST?
Enquire Now
FAQs
The B222-60FGFST is designed for 120/240V HVAC equipment with a 60A fused pullout, 10 kAIC interrupt rating, and a 15 A GFCI receptacle, making it suitable for outdoor rooftop units, condensers, and similar outdoor HVAC installations.
Yes, the B222-60FGFST is UL Listed and features a NEMA 3R galvanized steel enclosure, providing weatherproof protection for outdoor installations in varying climates.
It supports wire sizes up to #14-3 AWG Cu/Al and operates at 120/240 V with a 60 A rating and an interrupt rating of 10 kAIC, enabling safe and compliant integration into HVAC circuits.
The unit includes a 15 A ground fault self-test receptacle and a fused pullout design, which together improve fault detection, isolation safety, and serviceability during routine maintenance or repair work.
Eaton provides a policy referenced as 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first, to support installation teams and maintenance planning.