Eaton BP/FRN-R-20 fuse - RK5 Time-delay, CE Marked

Part Number: BP/FRN-R-20
Manufacturer
Eaton
Part number
BP/FRN-R-20

Quick Summary

The Eaton BP/FRN-R-20 fuse provides reliable motor protection in control panels and power distribution. Nuisance trips from inrush currents can stall automation cycles, so a time-delay design minimizes unnecessary outages. CE Marked and RK5 class compatibility, along with high interrupt ratings of 200 kAIC Vac and 20 kAIC Vdc, help ensure safe, compliant installations. This solution integrates seamlessly with ferrule-end wiring and standard blister packaging, offering predictable maintenance and a lower total cost of ownership for panel builders and OEMs in industrial environments. Engineers benefit from clear specs, fast replacement cycles, and consistent stock availability when upgrading legacy systems. Its ferrule-end design simplifies field termination and reduces installation time, helping maintenance teams meet tight project schedules.

Product Information

Extended Description

BP/FRN-R-20 Eaton: Eaton Bussmann series FRN-R fuse, Time-delay current-limiting fuse, 20 A, Dual, RK5, Non-indicating, Ferrule end x ferrule end, 8 sec at 500%, 20 kAIC Vdc, 200 kAIC V, Blister pack
Product Name
Eaton Bussmann series FRN-R fuse
Catalog Number
BP/FRN-R-20
UPC
051712112024
Product Length/Depth
2 in
Product Height
0.56 in
Product Width
0.56 in
Product Weight
0.124 lb
Compliances
CE Marked
Amperage Rating
20 A
Interrupt rating
200 kAIC Vac 20 kAIC Vdc
Response time
8 sec at 500%
Number of elements
Dual
Packaging type
Standard Blister
Class
Class RK5
Connection
Ferrule end x ferrule end
Fuse indicator
Non-indicating
Special features
Rejection style
Time-delay, current-limiting protection is a hallmark of the FRN-R line. This approach tolerates short inrush currents typical of motors, transformers, and power supplies, reducing nuisance trips during startup and accelerating line throughput. The result is higher machine availability, fewer emergency shutdowns, and smoother ramping of industrial processes. Engineers can rely on a single protective device across conveyors, pumps, and press lines without compromising safety or device longevity. Class RK5 compatibility and dual-element construction deliver selective protection and fast fault isolation. By matching common RK5 fuse blocks, BP/FRN-R-20 supports straightforward retrofits and standardized inventories. The dual elements provide redundancy in fault conditions while maintaining voltage and current ratings consistent with industrial panels. This reduces spare part complexity and simplifies procurement for OEMs building multi-line equipment. High interrupt ratings of 200 kAIC Vac and 20 kAIC Vdc ensure safe interruption of faults across both AC and DC bus architectures. With a response time of about 8 seconds at 500% overload, protection is fast enough to limit damage yet gentle enough to avoid unnecessary trips during normal startup. This translates to lower maintenance costs and longer service life for transformers, drives, and downstream devices. Ferrule-end terminations speed installation and improve reliability in harnessed panels. Ferrule-end terminations are compatible with common wiring harnesses and crimp tools, ensuring consistent termination quality in harsh plant environments and reducing rework due to loose connections. Non-indicating, rejection-style design helps prevent misidentification in crowded control panels, while blister packaging supports quick stocking and fast replacements during maintenance and retrofits.

Get a Quick Quote for a Eaton BP/FRN-R-20

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton BP/FRN-R-20? Enquire Now

FAQs

Power should be off before installation. Verify ferrule-end terminations and slide the BP/FRN-R-20 into the compatible RK5 holder with a firm seating. Ensure proper ferrule crimping and alignment to prevent loose connections. Tighten only to spec if torque guidance exists, and verify there is adequate clearance for vibration-prone panels.
The BP/FRN-R-20 excels in motor drives, conveyors, pumps, and automated machinery where brief inrush currents occur. Its 20 A rating, time-delay behavior, and 8 sec at 500% overload protect downstream controllers while allowing normal startup, delivering higher line efficiency, reduced downtime, and easier lifecycle management in industrial panels.
Yes, BP/FRN-R-20 is CE marked and designed for RK5 circuits. It offers an interrupt rating of 200 kAIC Vac and 20 kAIC Vdc, enabling safe fault interruption across both AC and DC systems and supporting compliant installations in European manufacturing environments and machine-building standards.
BP/FRN-R-20 can be used on DC circuits, with a 20 kAIC Vdc rating, suitable for mixed-technology panels. Proper coordination with upstream breakers and downstream contactors is essential. The dual-element RK5 construction helps maintain discrimination and reliable protection in combined AC/DC applications common in modern automation systems.
Using BP/FRN-R-20 reduces maintenance costs by lowering nuisance trips and extending equipment life through stable time-delay protection. Faster installation, standardized ferrule-terminals, and familiar FRN-R form factors simplify retrofits and stocking, delivering predictable ROI for OEMs and panel builders while minimizing downtime in high-inrush production environments.