Eaton BSPD400480D3P Surge Protection Device - NEMA 4X

Part Number: BSPD400480D3P
Manufacturer
Eaton
Part number
BSPD400480D3P

Quick Summary

BSPD400480D3P is a surge protection device designed to protect industrial electrical systems from transient overvoltages. Unplanned surges can cause downtime, equipment damage, and costly repairs, eroding productivity and margins. This model delivers robust protection in challenging environments thanks to a NEMA 4X enclosure, a 400 kAIC interrupt rating, and SCAQMD compliance where applicable. For panel builders, maintenance teams, and project managers, the BSPD400480D3P offers a reliable retrofit path within the Eaton Bussmann BSPD family, combining familiar integration with enhanced protection. By aligning with existing Eaton architectures, it reduces spares inventory and simplifies procurement, while delivering clear ROI through uptime gains and longer equipment life. The product name and catalog number are straightforward for ordering and field service.

Product Information

Extended Description

BSPD400480D3P Eaton: Eaton Bussmann series BSPD surge protection device, 400 kAIC, Surge protection device, BSPD series, NEMA 4X - BSPD400480D3P
Product Name
Eaton Bussmann series BSPD surge protection device
Catalog Number
BSPD400480D3P
UPC
786685934532
Product Length/Depth
14 in
Product Height
10 in
Product Width
10 in
Product Weight
18 lb
Compliances
SCAQMD compliance Contact Manufacturer
Type
Surge protection device
Enclosure
NEMA 4X
Interrupt rating
400 kAIC
Series
BSPD
Feature: 400 kAIC interrupt rating provides robust surge tolerance, which translates into reduced insulation stress on feeders and drives. Business impact: lowers the likelihood of catastrophic equipment damage and minimizes unplanned downtime, improving line uptime. Application: ideal for control panels and motor circuits in manufacturing environments where high-energy transients are common. Feature: NEMA 4X enclosure offers corrosion resistance and weatherproof protection, enabling both indoor and outdoor installations. Business impact: extends service life in harsh environments and reduces enclosure maintenance costs. Application: outdoor substations, exterior panels, and wash-down areas on industrial sites. Feature: Defined dimensional footprint (14 in depth, 10 in height, 10 in width) with a weight of 18 lb for straightforward mounting. Business impact: simplifies retrofits and SKUs management, accelerating installation and reducing labor time. Application: retrofit projects and new builds with space-constrained panels. Feature: Compatibility with the BSPD series and straightforward procurement using catalog BSPD400480D3P and UPC 786685934532. Business impact: lowers stocking complexity and ensures consistent protective strategy across multiple panels. Application: harmonized protection across Eaton Bussmann BSPD installations. Feature: SCAQMD compliance (where applicable) supports regulatory alignment and environmental responsibility. Business impact: reduces compliance risk and potential penalties, enabling smoother permitting processes. Application: California projects and facilities with stringent emission guidelines.

Get a Quick Quote for a Eaton BSPD400480D3P

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton BSPD400480D3P? Enquire Now

FAQs

BSPD400480D3P uses a NEMA 4X enclosure, designed for both indoor and outdoor use, including wash-down areas. Mounting should align with the 14 in depth, 10 in height, and 10 in width footprint, ensuring access to the catalog number BSPD400480D3P for serviceability. Plan for proper clearance and temperature conditions to maintain peak performance and ease of maintenance.
A 400 kAIC interrupt rating represents a high-energy surge tolerance, reducing insulation stress and the risk of transformer or switchgear damage. This translates to lower downtime and fewer field repairs, particularly for critical loads like PLCs, drives, and motor starters in demanding industrial lines.
Yes, the BSPD400480D3P aligns with SCAQMD compliance where applicable. For projects in California, confirm local permitting and ensure the installation adheres to environmental guidelines. The datasheet and Eaton support can verify specific compatibility for your site conditions.
Routine maintenance centers on visual inspections, verifying enclosure integrity, and confirming lead connections remain tight. The device’s high-visibility UPC and catalog information facilitate quick replacement if service is needed. Schedule periodic checks aligned with your preventive maintenance plan to sustain surge protection performance.
ROI stems from reduced surge-related outages, lower repair costs, and extended equipment life. While initial deployment costs are offset over time by uptime gains and fewer premature component failures, quantify expected downtime reductions from historical surge events to build a precise business case.