Eaton C0005P8ASES Industrial Control Transformer - UL

Part Number: C0005P8ASES
Manufacturer
Eaton
Part number
C0005P8ASES

Quick Summary

Eaton C0005P8ASES industrial control transformer powers control circuits from a 400 V primary to 120/240 V secondary in demanding equipment. Engineers often contend with voltage drift, cramped panel space, and wiring congestion that stall startups. This unit carries UL Recognized safety certification and RoHS compliance, with resin-encapsulated construction and 60 Hz operation for consistent performance in harsh environments. The design emphasizes copper windings, electrostatic shielding, and a compact frame that helps reduce heat buildup while simplifying panel wiring. By delivering stable control power, it enables reliable automation, reduces maintenance cycles, and supports scalable installations in modern manufacturing settings.

Product Information

Extended Description

C0005P8ASES Eaton: Eaton Type AP industrial control transformer, pv: 400v, taps: 2 at +2.5% fcan, 2 at -2.5% fcbn, sv: 120/240v, 115°c, 5000 va, cu magnet wire, elec. shield, frame: 257
Product Name
Eaton Type AP industrial control transformer
Catalog Number
C0005P8ASES
UPC
786680090745
Product Length/Depth
10.748 in
Product Height
12 in
Product Width
10.827 in
Product Weight
129 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
RoHS Compliant
Certifications
UL Recognized
Catalog Notes
Resin encapsulated, 60 Hz operation, 180°C insulation system, Convenient screw-type terminal board
Coil material
Copper windings
Design
AP
Frame
257
Tap size
2 at +2.5% FCAN, 2 at -2.5% FCBN
Wiring connection
405B
Primary voltage
400 V
Temperature rating
115°C
Volt ampere rating
5000 VA
Secondary voltage
120/240 V
Modification 1
Side/wall mounted
Special features
Electrostatically shielded
Feature: 400 V primary input and 120/240 V secondary output with a 5000 VA rating. Business Impact: Delivers robust, shared-control power for multiple panels or PLC inputs, reducing voltage drop and improving system uptime in automated lines. Application: Ideal for machine control enclosures and automation cabinets where stable control power is critical. Feature: Tap adjustments with 2 at +2.5% FCAN and 2 at -2.5% FCBN. Business Impact: Allows fine-tuning to counter supply variations, minimizing nuisance tripping and protecting sensitive electronics. Application: Panel power conditioning in regions with fluctuating mains voltage. Feature: Resin-encapsulated construction and 180°C insulation system. Business Impact: Increases ruggedness and insulation life in heat- and dust-prone environments, lowering replacement costs. Application: Heavy-duty manufacturing floors and outdoor enclosures where reliability is paramount. Feature: Copper windings with electrostatic shielding. Business Impact: Improves EMI performance and reduces interference with nearby control electronics, boosting signal integrity. Application: Dense control rooms or equipment with mixed analog and digital signals. Feature: Side/wall mounting, 405B wiring connection, and frame 257 with a 129 lb weight. Business Impact: Simplifies installation and wiring, supports retrofit projects, and enables secure mounting in compact panels. Application: Retrofit upgrades and new panel builds in OEM and industrial settings. Feature: RoHS compliant and UL Recognized with 60 Hz operation. Business Impact: Ensures regulatory compliance and safety, enabling easier procurement and supplier qualification. Application: Standardized power transformation for industrial equipment across manufacturing facilities.

Get a Quick Quote for a Eaton C0005P8ASES

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton C0005P8ASES? Enquire Now

FAQs

What mounting and wiring steps are recommended? The unit supports side/wall mounting and uses a 405B wiring terminal board. When installing, ensure proper clearance for cooling, connect the 400 V primary to the input and tie the 120/240 V secondary to the control circuits. Verify taps are set to match supply conditions and secure the transformer firmly to avoid vibration.
The transformer features a 400 V primary and a 120/240 V secondary, rated at 5000 VA. It operates at 60 Hz, with copper windings and a 180°C insulation system, suitable for demanding industrial control applications requiring reliable power conversion.
Yes. It is RoHS compliant and UL Recognized, ensuring regulatory compliance and safety in electrical installations. This reduces procurement risk and simplifies supplier qualification for industrial projects.
Best suited for control panels in manufacturing and automation equipment, where stable 120/240 V control power is needed from a 400 V feed. Its shielded design minimizes EMI, making it suitable for PLCs, servo drives, and other sensitive electronics in dense panel layouts.
Copper windings and resin encapsulation provide rugged durability and long insulation life, reducing maintenance frequency. EMI shielding lowers interference-related downtime, and the side-mount, compact frame simplifies retrofits and panel upgrades, delivering cost savings over time.