Eaton CB1233T120208RA9 Pressure Contact Switch - UL Listed

Part Number: CB1233T120208RA9
Manufacturer
Eaton
Part number
CB1233T120208RA9

Quick Summary

CB1233T120208RA9 pressure contact switch provides reliable single-phase protection for industrial electrical systems in panels and switchgear. Engineers often struggle with coordinating protection and trip timing in compact control panels, which can lead to unplanned downtime and safety risks. UL Listed and NEMA-rated for indoor and harsh environments (NEMA 1, 3R, 4, 12) ensure compliant performance across plant floors and enclosures. Designed for high-current applications, it integrates with Eaton switching devices and standard control circuits, reducing wiring complexity and maintenance costs. Optional features such as Ground Fault Relay, Blown Fuse Detection, and auxiliary provisions enable scalable protection strategies as facilities evolve.

Product Information

Extended Description

CB1233T120208RA9 Eaton: Eaton pringle bolted pressure contact switch,Single-phase relay with capacitor trip device (SPVR), BFD with three on lights (trips switch),1200A,120V,Top feed,No ground fault,208V,Three-pole,Three-wire,Fusible
Product Name
Eaton pringle bolted pressure contact switch
Catalog Number
CB1233T120208RA9
UPC
782116956043
Product Length/Depth
16 in
Product Height
28 in
Product Width
24 in
Product Weight
180 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
OPTIONAL Ground Fault Relay, Blown Fuse Detection, Single Phase Protection, Kirk Provisions, Auxiliary Contact Provisions, AVAILABLE.
Feed type
Top
Fuse configuration
Top feed
Ground
No ground fault
Number Of Poles
Three-pole
Number of wires
3
Switch type
Electrical trip with charge-before-close mechanism
Type
Pringle bolted pressure contact switch
Amperage Rating
1200A
Control voltage
120 V
NEMA rating
NEMA 1, NEMA 3R, NEMA 4, NEMA 12
Protection
Fusible
System voltage
208 V
Voltage - max
208 V
Voltage rating
208 V
Special features
Single-phase voltage relay with capacitor trip device (SPVR), BFD with three normally on lights (trips switch)
The single-phase relay with a capacitor trip device (SPVR) delivers a precise, fast trip sequence, enhancing circuit protection. This architecture minimizes nuisance trips and improves safety margins in motor circuits subject to inrush and fault transients. Ideal for motor control centers and panelboards where predictable response times directly impact uptime. With a 1200A amperage rating and 208V system voltage paired with a 120V control voltage, the CB1233T120208RA9 supports large motors and heavy feeders while keeping control power reliable. This combination reduces the need for upgrades when plant loads change and simplifies protection coordination with downstream devices. Applications include manufacturing lines, pumps, and material handling where high current and robust protection are essential. Top-feed configuration and three-pole, three-wire construction streamline wiring inside enclosures, cutting installation time and potential misconnections. The fusible protection option provides selective protection, allowing fuses to be sized to protect feeders and individual circuits. This setup is well-suited for retrofit projects where existing top-fed panels are in service. NEMA ratings of 1, 3R, 4, and 12, along with UL Listing, give designers confidence in this switch’s performance across ambient conditions and enclosure types. The device supports single-phase protection with BFD indicators and auxiliary contact provisions, simplifying status monitoring and maintenance. These certifications help support compliance programs in food & beverage, water treatment, and general manufacturing. Catalog notes indicate optional Ground Fault Relay, Blown Fuse Detection, Single Phase Protection, Kirk Provisions, and Auxiliary Contact Provisions are available, enabling scalable protection architectures. When combined with Eaton switching devices and standard control circuits, the CB1233T120208RA9 fits neatly into existing control schemes. This reduces risk during upgrades and helps ensure consistent protection across new and legacy equipment.

Get a Quick Quote for a Eaton CB1233T120208RA9

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton CB1233T120208RA9? Enquire Now

FAQs

CB1233T120208RA9 uses a top-feed configuration with three-pole, three-wire design, simplifying wiring in control panels and switchgear. Ensure enclosure clearance matches the 24x16x28 inch profile and verify available space for the fusible protection option. Check that the panel supports 208 V system power and a 120 V control circuit to maintain reliable protection without wire rewiring.
The capacitor trip device (SPVR) provides a controlled, capacitor-assisted trip sequence that reduces nuisance trips during inrush and transient faults. This leads to faster, more predictable shutdown of problematic feeders, minimizing arc exposure and equipment damage while maintaining safe startup sequences for motors and drives.
Yes, the CB1233T120208RA9 is UL Listed, signaling compliance with recognized safety standards for electrical protection devices. This supports regulatory acceptance in many jurisdictions, simplifies procurement paperwork, and streamlines acceptance testing for panels, switchgear, and industrial automation projects.
This switch is ideal for high-current motor feeders, large panel assemblies, and switchgear in manufacturing and process environments. Its 1200A rating, 208V system compatibility, and optional fault-detection features make it suitable for heavy-duty applications such as conveyors, pumps, and line-start protection schemes.
The device’s robust protection, UL-listed assurance, and optional features like Ground Fault Relay and Blown Fuse Detection reduce maintenance interruptions and unplanned downtime. By simplifying wiring and status monitoring through auxiliary provisions, facilities achieve faster fault diagnosis, lower service costs, and improved equipment uptime over the life of the installation.