Eaton CB1633B120208AXCT is a bolted pressure switch used for three-pole protection in industrial switchgear. Facilities teams often struggle with nuisance trips and coordination between devices in 208V systems. UL Listed certification supports safety compliance, while the unit’s rugged, NEMA-rated enclosure options tolerate harsh plant environments. The design includes a charge-before-close mechanism and a 1600A fault rating, with 208V system voltage and 120V control to fit standard control schematics. This combination delivers robust protection, reduces unplanned downtime, and lowers lifecycle costs for panel builders and maintenance teams.

Product Information

Extended Description

CB1633B120208AXCT Eaton: Eaton pringle bolted pressure contact switch,BFD with no lights (trips switch),,1600A,120V,Bottom feed,No ground fault,208V,Three-pole,Three-wire,Fusible
Product Name
Eaton pringle bolted pressure contact switch
Catalog Number
CB1633B120208AXCT
UPC
782116958924
Product Length/Depth
16 in
Product Height
32 in
Product Width
24 in
Product Weight
200 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
OPTIONAL Ground Fault Relay, Blown Fuse Detection, Single Phase Protection, Kirk Provisions, Auxiliary Contact Provisions, AVAILABLE.
Feed type
Bottom
Fuse configuration
Bottom feed
Ground
No ground fault
Number Of Poles
Three-pole
Number of wires
3
Switch type
Electrical trip with charge-before-close mechanism
Type
Pringle bolted pressure contact switch
Amperage Rating
1600A
Control voltage
120 V
NEMA rating
NEMA 1, NEMA 3R, NEMA 4, NEMA 12
Protection
Fusible
System voltage
208 V
Voltage - max
208 V
Voltage rating
208 V
Special features
BFD with no lights (trips switch), with control power transformer
Feature: Amperage rating of 1600A and fusible protection. Benefit: Enables high fault-current handling while coordinating with upstream protection to minimize damage to conductors and equipment. Application: Large motor feeders in manufacturing or processing facilities. Feature: 208V system voltage and 120V control voltage. Benefit: Simplifies integration with standard plant power and control circuits, reducing installation complexity. Application: Control panels and motor control centers. Feature: Three-pole bottom-fed configuration. Benefit: Easier wiring, faster panel integration, and simpler maintenance in tight spaces. Application: Industrial switchgear and distribution panels. Feature: Optional Ground Fault Relay, Blown Fuse Detection, Auxiliary Contacts. Benefit: Enhanced protection signaling and remote monitoring capabilities, lowering risk of undetected faults. Application: Safety interlocks and protection schemes. Feature: NEMA ratings 1, 3R, 4, 12. Benefit: Rugged enclosure performance in harsh environments, improving uptime. Application: Factories with dust, moisture, or outdoor exposure. Feature: Charge-before-close mechanism. Benefit: Safer operation with controlled switching during energization sequences. Application: High-energy switching in critical loads. Feature: Size and weight (16 in x 32 in x 24 in; 200 lb). Benefit: Predictable enclosure footprint for panel design and installation planning. Application: Large control cabinets and MCCs.

Get a Quick Quote for a Eaton CB1633B120208AXCT

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton CB1633B120208AXCT? Enquire Now

FAQs

Begin by confirming exact ratings (1600A, 208V system, 120V control) and ensuring enclosure compatibility (NEMA 1, 3R, 4, 12). Mount the unit in a bottom-fed position per catalog notes, wire the three poles in a three-wire arrangement, and connect to the control transformer if used. Verify ground fault options are wired correctly and document auxiliary contacts for signaling.
The switch is rated for 1600A with a 208V system voltage and 120V control voltage, featuring fusible protection and a three-pole configuration. It supports bottom feed and is UL Listed. The NEMA-rated enclosure options offer suitability across a range of industrial environments, aiding reliability in large motor feeders and panel assemblies.
Yes. This unit is designed for large-motor feeders and distribution panels, providing robust protection with a charge-before-close mechanism. Its 208V system compatibility and 120V control voltage streamline integration with standard plant controls, while optional features extend protection signaling and remote monitoring for critical manufacturing processes.
CB1633B120208AXCT is UL Listed, ensuring compliance with safety standards for low-voltage protective devices. It also carries NEMA enclosure ratings (1, 3R, 4, 12), which guide where the switch can be installed in tougher industrial environments and how it should be mounted within switchgear and MCCs.
Consider the one-year Eaton warranty from installation or 18 months from shipment, whichever comes first, and plan for routine inspections of fusible protection and contact integrity. The optional Ground Fault Relay, blown fuse detection, and auxiliary contacts support predictive maintenance and faster fault diagnostics, reducing downtime and extending panel lifecycle.