Eaton CB1633B120480GAX7 Pressure Contact Switch - UL Listed

Part Number: CB1633B120480GAX7
Manufacturer
Eaton
Part number
CB1633B120480GAX7

Quick Summary

Eaton CB1633B120480GAX7 pressure contact switch is designed to trip on fault in three-phase, bottom-fed 480V systems. The goal is to reduce downtime by providing reliable, fast protection in demanding industrial environments. Maintenance teams often struggle with nuisance trips and inconsistent protection; this unit delivers a clean, Fusible protection strategy with robust mechanical integrity. UL Listed certification and compatible NEMA ratings (1, 3R, 4, 12) support safe integration into standard control enclosures. By aligning with Eaton switching devices and common control voltages, this switch streamlines procurement and installation, delivering measurable value through safer operations and longer equipment life.

Product Information

Extended Description

CB1633B120480GAX7 Eaton: Eaton pringle bolted pressure contact switch,BFD with no lights (trips switch),1600A,2NO-2NC,120V,Bottom feed,Ground fault,480V,Three-pole,Three-wire,Fusible
Product Name
Eaton pringle bolted pressure contact switch
Catalog Number
CB1633B120480GAX7
UPC
782116958597
Product Length/Depth
16 in
Product Height
32 in
Product Width
24 in
Product Weight
200 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
OPTIONAL Ground Fault Relay, Blown Fuse Detection, Single Phase Protection, Kirk Provisions, Auxiliary Contact Provisions, AVAILABLE.
Contact configuration
2 NO-2 NC
Feed type
Bottom
Fuse configuration
Bottom feed
Ground
Ground fault with control power transformer
Number Of Poles
Three-pole
Number of wires
3
Switch type
Electrical trip with charge-before-close mechanism
Type
Pringle bolted pressure contact switch
Amperage Rating
1600A
Control voltage
120 V
NEMA rating
NEMA 1, NEMA 3R, NEMA 4, NEMA 12
Protection
Fusible
System voltage
480 V
Voltage - max
480 V
Voltage rating
480 V
Special features
BFD with no lights (trips switch)
Feature: 2 NO-2 NC contact configuration. Business Impact: Provides flexible interlock and signaling options for complex control schemes, reducing wiring errors and enabling precise trip coordination. Application: Three-pole motor feeders and switchgear in manufacturing lines. Long-tail keywords: bolted pressure contact switch, three-pole electrical switch, 2NO-2NC configuration. Feature: Bottom feed and fusible protection. Business Impact: Simplifies panel wiring and enhances fault isolation, lowering installation time and material costs. Application: Enclosed control panels in dusty or humid environments. Long-tail keywords: bottom feed disconnect, fusible switch, control panel protection. Feature: Ground fault with control power transformer. Business Impact: Improves safety and fault detection on ground faults without compromising control power. Application: Industrial power distribution with sensitive electronics. Long-tail keywords: ground fault protection, control power transformer, low-voltage protection. Feature: High amperage rating of 1600A. Business Impact: Supports large motor and feeder protection, reducing the need for multiple devices and simplifying coordination. Application: High-current switchgear, main feeders. Long-tail keywords: 1600A protection, high-current switch, motor feeder protection. Feature: 120V control voltage and UL listing. Business Impact: Standardized control interfaces simplify integration with existing control circuits and ensure safety compliance. Application: 120V control circuits in industrial environments. Long-tail keywords: 120V control voltage, UL Listed switch, industrial control compatibility. Feature: Optional ground fault relay, blown fuse detection, single-phase protection, auxiliary provisions. Business Impact: Additive protection capabilities without replacing the base switch, enabling scalable safety features. Application: Retrofit projects and upgrade campaigns in evolving facilities. Long-tail keywords: optional protection features, auxiliary contact provisions, Kirk provisions. The combination of these features supports a robust, compliant protection strategy, minimizes downtime, and aligns with enterprise maintenance programs across manufacturing and processing facilities.

Get a Quick Quote for a Eaton CB1633B120480GAX7

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton CB1633B120480GAX7? Enquire Now

FAQs

Choose CB1633B120480GAX7 for three-pole, bottom-fed assemblies with 2NO-2NC contacts to match existing control logic. Ensure enclosure is rated for the NEMA 1, 3R, 4, 12 environments and that the frame supports fusible protection. Optional provisions like auxiliary contacts and Kirk provisions can simplify integration with existing Eaton devices.
A 1600A rating handles high fault currents typical of large feeders and motors, reducing the need for multiple devices. Select complementary fusible protection sized for anticipated faults and confirm enclosure clearance. Coordination with downstream devices and proper grounding minimize nuisance trips while maintaining fast, reliable protection during faults.
Yes. The unit provides a 120V control voltage suitable for standard industrial control circuits. Its ground fault options and control power transformer support safer operation in facilities that require reliable control power. When integrating, verify control wiring meets 120V practices and that any optional ground fault relay is compatible with the overall control scheme.
The CB1633B120480GAX7 is UL Listed, ensuring compliance with electrical safety standards for industrial equipment. It also carries NEMA ratings of 1, 3R, 4, and 12, enabling reliable operation in enclosures exposed to dust, moisture, and varying temperatures. These certifications support audits, vendor qualification, and safe deployment in regulated industries.
The switch’s high-current capability, robust enclosure compatibility, and optional protection features reduce downtime by delivering dependable trips and fewer nuisance events. Integration with existing Eaton devices streamlines spare parts and maintenance planning, while UL/NEMA compliance lowers retrofit risk and extends service life for critical plant feeders.