Eaton CCP2S-2-100CF Fusible Disconnect - UL98 Certified
Part Number: CCP2S-2-100CF
Quick Summary
CCP2S-2-100CF is a UL98 fusible disconnect for safe isolation of 600 VAC circuits in industrial panels. Engineers often struggle with space, wiring complexity, and ensuring safe isolation during fault conditions. This CCP2S-2-100CF is designed to meet UL98 requirements for fusible disconnects, supports up to 200 kAIC short-circuit rating, and operates at 60 Hz. Built for industrial panels with a two-pole design, compact dimensions, and straightforward installation, it reduces wiring footprint and maintenance costs while delivering reliable isolation.
Product Information
Extended Description
CCP2S-2-100CF Eaton: Eaton Bussmann series CCP UL98 fusible disconnect, 600 Vac, 125 Vdc, 100A, UL98 fusible disconnect, Two-pole, 60 Hz, CUBEFuse, 200 - CCP2S-2-100CF
Product Name
Eaton Bussmann series CCP UL98 fusible disconnect
Catalog Number
CCP2S-2-100CF
UPC
051712710046
Product Length/Depth
3.4 in
Product Height
5.3 in
Product Width
3 in
Product Weight
1.43 lb
Warranty
Not Applicable
Certifications
Contact Manufacturer
Amperage Rating
100A
Frequency rating
60 Hz
Short-circuit rating
200 kAIC
Voltage rating
600 Vac, 125 Vdc
Fuse type
CUBEFuse
Number Of Poles
Two-pole
Suitable for fuses
TCF6 to TCF100 TCF1RN to TCF100RN FCF1RN to FCF100RN
Bussmann series complete full line catalog no. 1007
Bussmann series complete full line catalog no. 1007
Eaton Specification Sheet - CCP2S-2-100CF
Feature: 100 A rating with 600 VAC and 125 VDC limits. Business Impact: Enables safe, high-current disconnection across common industrial loads while meeting voltage requirements. Application: Motor control centers, feeders, and power distribution panels where reliable sectionalization is critical. Feature: UL98 fusible disconnect with CUBEFuse construction. Business Impact: Improves safety, selectivity, and fault isolation, reducing nuisance outages. Application: Service panels and equipment rooms requiring code-compliant disconnection. Feature: 200 kAIC short-circuit rating. Business Impact: High fault tolerance minimizes equipment damage and downtime during faults. Application: Heavy-duty motor drives and high-inrush circuits. Feature: Compact form factor (3.4 in depth × 5.3 in height × 3 in width) and 1.43 lb weight. Business Impact: Easier integration into tight control cabinets and crowded panels, saving space and labor during installation. Application: New builds and retrofits with limited enclosure space. Feature: Two-pole design. Business Impact: Simplifies wiring, reduces installation time, and improves safety monitoring on dual-conductor circuits. Application: Standalone disconnects and multi-point motor protection schemes. Feature: Compatibility with Bussmann fuses (TCF6–TCF100, TCF1RN–TCF100RN, FCF1RN–FCF100RN). Business Impact: Broad fuse interoperability lowers stock diversity and simplifies maintenance. Application: Replacements and upgrades across existing CCP-based installations.
Get a Quick Quote for a Eaton CCP2S-2-100CF
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton CCP2S-2-100CF?
Enquire Now
FAQs
Begin with de-energizing the panel and confirming proper lockout/tagout. Mount the CCP2S-2-100CF in a suitable enclosure, align the two-pole terminals for secure mounting, and connect conductors per the wiring diagram. Use the recommended Bussmann fuse range (TCF6–TCF100, TCF1RN–TCF100RN, FCF1RN–FCF100RN) and torque specifications to ensure reliable connection and fault performance.
The device is rated for 100 A, 60 Hz operation, with a voltage rating of 600 VAC and 125 VDC. It provides a short-circuit rating of 200 kAIC, and uses a CUBEFuse fuse type. It is a two-pole disconnect designed for industrial power distribution and motor-control applications.
Yes, the 100 A, two-pole CCP2S-2-100CF is suitable for industrial motor protection when paired with appropriate Bussmann fuses and protective accessories. Its 200 kAIC short-circuit rating supports high fault withstand, helping protect downstream drives and cabling in the event of faults.
The CCP2S-2-100CF is specified as a UL 98 fusible disconnect, providing UL-listed protection for disconnecting means in electrical circuits. Always verify current listings and regional compliance requirements for your installation, as Certifications can affect panel approvals and safety documentation.
Regular fuse-based isolation simplifies replacement and minimizes downtime during maintenance or fault clearing. The compact footprint and straightforward wiring reduce labor costs during installation. With broad fuse compatibility and high fault current tolerance, operational reliability translates to lower unscheduled outages and improved total cost of ownership for panel upgrades.