Eaton CHP14B100 Main Breaker Loadcenter - 10 kAIC
Part Number: CHP14B100
Quick Summary
CHP14B100 main breaker loadcenter from Eaton is designed for reliable 120/240 V service in commercial and light industrial settings. This configuration delivers 28 circuits across 14 spaces with a 100 A main breaker, offering a compact footprint for crowded electrical rooms. The enclosure is NEMA 1 metallic indoor, with a cover included for quick installation. Key certifications include UL 67 and UL 50 recognition, ensuring safe operation and panel compliance. The CH series is known for field reliability and ease of maintenance, reducing downtime and service costs. For project teams, this model pairs well with copper bus and CH series breakers, delivering robust protection and straightforward wiring for control panels and service entrances.
Product Information
Extended Description
CHP14B100 Eaton: Eaton CH main breaker loadcenters,Main breaker,100 A,X1,Copper,Cover included,NEMA 1 indoor,Metallic,10 kAIC,CH,28,14,Three-wire,Single-phase,#6-1/0 AWG,120/240 V
Product Name
Eaton CH main breaker loadcenter
Catalog Number
CHP14B100
UPC
786689054564
Product Length/Depth
23.2 in
Product Height
4.7 in
Product Width
15.9 in
Product Weight
18.15 lb
Warranty
Limited lifetime
Certifications
UL 67 UL 50
Catalog Notes
Retail Packaging
Type
Main breaker
Amperage Rating
100 A
Bus material
Copper
Cover
Cover included
Main circuit breaker
CH
Number of circuits
28
Number of spaces
14
Phase
Single-phase
Wire size
#6-1/0 AWG
Voltage rating
120/240 V
Box size
X1
Enclosure
NEMA 1
Enclosure material
Metallic
Interrupt rating
10 kAIC
Number of wires
3
AFCI Educational Video
Eaton Specification Sheet - CHP14B100
Eaton type CH circuit breaker limited warranty June 2024
Feature → Business Impact → Application: The CHP14B100 uses a 100 A main breaker with 28 circuits across 14 spaces and single-phase 120/240 V operation, fed by copper bus bars. Business Impact: This configuration delivers reliable overcurrent protection while maximizing circuit density, reducing panel depth and improving heat management in crowded electrical rooms. Application: Ideal for service entrances, commercial panels, and light industrial control rooms where space is at a premium and future expansion is anticipated. Feature → Business Impact → Application: The enclosure is a NEMA 1 metallic indoor cabinet with a cover included and a 10 kAIC interrupt rating. Business Impact: Provides robust protection against dust and incidental damage while enabling quick installation and service access. Application: Suitable for indoor electrical rooms in offices, retail complexes, and manufacturing floors. Feature → Business Impact → Application: Copper bus material with #6-1/0 AWG wiring and 14 spaces supports robust current flow and easy termination. Business Impact: Reduces contact resistance and enables consistent performance under high-load conditions, while simplifying conductor terminations for future upgrades. Application: Used in automation panels, motor control centers, and distribution boards. Feature → Business Impact → Application: CH main breaker compatibility with UL 67 and UL 50 listings ensures compliance and broad parts availability. Business Impact: Lowers procurement risk and streamlines QA, making warranty claims and field service more straightforward. Application: Required in regulated facilities and when building code compliance is mandatory. Feature → Business Impact → Application: Includes cover and back panel assembly; dimensions 23.2 in depth, 15.9 in width, 4.7 in height; weight 18.15 lb. Business Impact: Facilitates installation planning and ensures proper fit in tight spaces, reducing retrofit time and inventory concerns. Application: Retrofit projects and new builds where exact dimensions matter.
Get a Quick Quote for a Eaton CHP14B100
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton CHP14B100?
Enquire Now
FAQs
Begin by verifying 120/240 V single-phase supply and turning off power. Mount the CHP14B100 enclosure in the designated space, secure to the backbox, and align with DIN rails. Terminate conductors up to #6-1/0 AWG to the copper bus per the CH series guidelines, then install the cover. Ensure appropriate clearances and torque values per Eaton's specifications to complete a code-compliant retrofit.
CHP14B100 features a 100 A main breaker, 28 circuits across 14 spaces, copper bus, 120/240 V single-phase, NEMA 1 indoor metallic enclosure, cover included, and a 10 kAIC interrupt rating. The wiring is compatible with #6-1/0 AWG conductors, and the unit supports CH series breakers for expansion while maintaining UL 67 and UL 50 compliance.
Yes. The NEMA 1 indoor metallic enclosure with a cover provides solid protection in typical commercial rooms, and the 100 A main breaker with 28 circuits supports scalable distribution for service entrances and light industrial applications. Its copper bus and CH series compatibility enhance reliability, while UL certifications help ensure compliance with essential safety and performance standards.
CHP14B100 is UL 67 and UL 50 certified, indicating it meets recognized standards for electrical enclosures and general-purpose switchgear. These certifications support safe operation, reliability, and ease of procurement, reducing QA checks and warranty disputes while facilitating compliance with electrical codes in commercial and light industrial facilities.
The 100 A CH loadcenter benefits from a limited lifetime warranty and durable metallic NEMA 1 construction, reducing downtime and service calls. Copper bus bars offer low resistance and better long-term performance, lowering energy losses. The enclosure cover ships with the unit, speeding installation and enabling quicker returns on investment for new projects or panel retrofits.