Eaton CHP14B100R Main Breaker Loadcenter - NEMA 3R
Part Number: CHP14B100R
Quick Summary
The Eaton CHP14B100R main breaker loadcenter delivers reliable 120/240 V power distribution for service panels. Engineers often struggle with service equipment sizing, weatherproofing, and installation complexity in tight spaces. UL 50 and UL 67 certifications provide electrical and enclosure compliance, while the NEMA 3R metallic enclosure offers rainproof protection. This unit's 14 spaces and 28 circuits, copper bus, and a cover included support fast installation, scalable expansion, and reduced maintenance, helping procurement control costs across projects. Designed for industrial environments, it supports overhead feed and single-phase configurations, aligning with Eaton CH accessories for a smooth lifecycle.
Product Information
Extended Description
CHP14B100R Eaton: Eaton CH main breaker loadcenters,Cover included,Main breaker,100 A,X0,Copper,NEMA 3R,Metallic,CH,28,14,Three-wire,Single-phase,Overhead,120/240 V
Product Name
Eaton CH main breaker loadcenter
Catalog Number
CHP14B100R
UPC
786689058517
Product Length/Depth
16.75 in
Product Height
5.19 in
Product Width
14.31 in
Product Weight
18 lb
Warranty
Limited lifetime
Certifications
UL 50 UL 67
Catalog Notes
Suitable for use as service equipment when not more than six service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Rainproof panels are furnished with hub closure plates. For rainproof hubs.
Special features
Cover included
Type
Main breaker
Amperage Rating
100 A
Bus material
Copper
Main circuit breaker
CH
Number of circuits
28
Number of spaces
14
Phase
Single-phase
Feed type
Overhead
Voltage rating
120/240 V
Box size
X0
Enclosure
NEMA 3R
Enclosure material
Metallic
Number of wires
3
AFCI Educational Video
Eaton Specification Sheet - CHP14B100R
Eaton type CH circuit breaker limited warranty June 2024
The CHP14B100R is a 100 A main breaker loadcenter built around an Eaton CH main breaker, delivering robust protection for branch circuits. In practice, this reduces fuse requirements, improves coordination with feeders, and simplifies panel schedules for electrical installations in commercial or light industrial facilities. The unit supports single-phase, overhead feed at 120/240 V, and its 14-space, 28-circuit format provides clear room for growth. With 14 spaces and 28 circuits, this loadcenter supports mid-sized distribution while leaving headroom for future expansion. Copper bus bars offer lower resistance and superior heat dissipation, improving trip performance under peak loads. The combination of copper conductors and a CH main breaker enhances reliability in demanding environments. The NEMA 3R metallic enclosure delivers rainproof protection for outdoor or damp locations, reducing field modifications and strengthening compliance for exterior service equipment. Rainproof hubs and compatible cover designs further simplify installation in variable weather. Overall, the enclosure is designed for rugged industrial use where protection and longevity matter. Compatibility and installation efficiency are improved by native CH breaker compatibility and Eaton accessories, enabling streamlined procurement and consistent spare parts stocking. The unit ships with a cover included, protecting internal components during install and reducing protective hardware requirements. The limited lifetime warranty adds long-term value by lowering maintenance risk and supporting a lower total cost of ownership. Dimensions and mounting considerations are aligned with standard practice to facilitate retrofits and new installations, with a depth of 16.75 in, width of 14.31 in, height of 5.19 in, and a weight of 18 lb to ease handling and installation.
Get a Quick Quote for a Eaton CHP14B100R
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton CHP14B100R?
Enquire Now
FAQs
CHP14B100R is a 100 A main breaker loadcenter with 14 spaces and 28 circuits for 120/240 V single-phase service. It uses overhead feed, copper bus, and accepts CH series breakers. The enclosure is NEMA 3R metallic with a cover included, enabling outdoor or damp-location installations with straightforward wiring and safe access to conductors.
Yes. The CHP14B100R is designed to accept Eaton CH circuit breakers, and it is compatible with Eaton accessories, aiding in procurement, parts stocking, and future expansion. This compatibility simplifies maintenance, ensures consistent performance, and reduces cross-brand integration concerns during upgrades or replacements.
The CHP14B100R carries UL 50 and UL 67 certifications, acknowledging safe enclosure and component performance. It features a NEMA 3R metallic enclosure for weather resistance and a 100 A main breaker with copper bus. A limited lifetime warranty further supports reliability and long-term maintenance planning.
The unit uses a NEMA 3R metallic enclosure with rainproof hubs and a cover included, which protects internal components from rain, dust, and incidental contact. This makes it suitable for outdoor service equipment installations and damp environments, reducing the need for field enclosure modifications while satisfying code requirements.
The loadcenter measures 16.75 in in depth, 14.31 in in width, and 5.19 in in height, weighing 18 lb. These dimensions align with standard mounting practices and facilitate overhead-feed installations. The unit supports straightforward wiring, with copper bus and CH main breaker compatibility aiding retrofit projects and new builds alike.