Eaton CV3110 CH thermal magnetic circuit breaker - 65 kAIC

Part Number: CV3110
Manufacturer
Eaton
Part number
CV3110

Quick Summary

Eaton CV3110 CH thermal magnetic circuit breaker protects industrial electrical panels in distribution systems. This device delivers reliable overcurrent protection for three-pole circuits up to 100 A, helping you maintain uptime in demanding environments. Design engineers often battle nuisance trips, mis-sizing, and slow fault isolation that disrupt production and escalate maintenance costs. The CV3110 is a molded case circuit breaker with a 65 kAIC interrupt rating at 240 V, and it supports line and load terminals for straightforward installation. Certification specifics vary by region; refer to Eaton documentation for applicable approvals and compliance notes. By combining robust protection with easy integration, this solution enhances electrical protection strategy while driving operational efficiency and safety.

Product Information

Extended Description

CV3110 Eaton: CV 3 Pole 100 Amps 65kA 240 V Line and Load Terminals
Product Name
Eaton CH thermal magnetic circuit breaker
Catalog Number
CV3110
UPC
786685953809
Product Length/Depth
7.5 in
Product Height
5 in
Product Width
5 in
Product Weight
4.2 lb
Certifications
Contact Manufacturer
Type
Molded Case Circuit Breaker
Amperage Rating
100 A
Voltage rating
240 V - 240 V
Circuit breaker type
CV
Terminals
Line and load
Interrupt rating
65 kAIC
Number of poles
Three-pole
Feature → Three-pole design provides synchronized protection for three-phase circuits. Business Impact → Improves fault isolation and reduces cross-phase faults, increasing system reliability. Application → Ideal for motor feeds, conveyors, and process lines in manufacturing environments. Feature → 65 kAIC interrupt rating at 240 V. Business Impact → Enables safe interruption of high fault currents common in heavy industry, protecting equipment further downstream. Application → Suitable for main feeders and critical branch circuits in harsh plant settings. Feature → 100 A nominal rating with line and load terminals. Business Impact → Precise sizing reduces nuisance trips, minimizes energy waste, and simplifies wiring. Application → Used for feeders to motors, pumps, and control panels. Feature → Molded case construction within Eaton CH family. Business Impact → Compact footprint with robust protection and straightforward installation. Application → Retrofit or new panel designs in electrical protection and circuit control. Feature → 240 V operating range. Business Impact → Aligns with common industrial power distribution standards, easing procurement and panel integration. Application → Suitable for global plant electrical distribution that employs three‑phase 240 V systems.

Get a Quick Quote for a Eaton CV3110

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton CV3110? Enquire Now

FAQs

To install the CV3110, verify three-pole mounting and ensure correct orientation for line and load terminals. Connect the three incoming phase conductors to the line terminals and the protected circuits to the load terminals. Confirm the unit is rated for 240 V and 100 A with a 65 kAIC interrupt capability. Tighten all connections to the manufacturer’s torque recommendations and secure the breaker within a compatible CH panel frame. This approach minimizes nuisance trips and ensures reliable coordination with downstream devices.
65 kAIC indicates the maximum fault current the breaker can interrupt without electrical or mechanical damage. It is essential for systems with high fault currents, such as large motors or feeders connected to robust power supplies. In facilities where fault currents may approach or exceed standard levels, selecting a 65 kAIC-rated CH breaker like the CV3110 helps ensure safe isolation, equipment protection, and compliance with design standards.
Yes. The CV3110 is a three‑pole molded case circuit breaker designed for motor feeders and other inductive loads in industrial settings. Its thermal magnetic operation provides overload protection and short‑circuit interruption, helping to prevent motor burnout and equipment damage. For motor start‑ups with high inrush, the CH series offers coordination options and appropriate interrupt ratings to balance protection with reliability.
Certification details for CV3110 vary by region. The data indicates “Certifications: Contact Manufacturer,” so verify regional approvals directly with Eaton for your locale. In practice, CH series breakers commonly align with global standards and local electrical codes; check the Eaton specification sheet and regional certificates to ensure compliance for your installation and maintenance program.
CH series breakers, including CV3110, are designed for long service life with minimal maintenance when installed correctly and operated within rated conditions. Regular inspections of mounting integrity, terminals, and enclosure cleanliness help prevent overheating and contact wear. By avoiding nuisance trips and extending replacement intervals, you reduce unplanned downtime and maintenance costs, improving total cost of ownership for panel protection and system reliability.