Eaton DCU1062UPM DC Disconnect - UL 98B/NEC 690

Part Number: DCU1062UPM
Eaton logo
Manufacturer
Eaton
Part number
DCU1062UPM

Quick Summary

Eaton DCU1062UPM DC disconnect is a rugged switch designed to safely interrupt and isolate DC power in solar installations. The design addresses common field challenges like weather exposure, reliable isolation, and compliance with strict PV codes. It carries UL 98B and NEC 690 per UL 1741 certifications, backed by a NEMA 4 enclosure and a 600 VDC rating to perform in harsh outdoor environments. By delivering a non-fusible, ungrounded solution with a robust painted galvanized steel enclosure, it reduces risk during routine maintenance and string commissioning. The unit supports diverse conductor configurations and integrates smoothly with #14-#2 AWG lugs and #14-1/0 AWG returns, enabling flexible system layouts and faster install times.

Product Information

Extended Description

DCU1062UPM Eaton: Eaton heavy duty DC disconnect,DC disconnect/ungrounded system,60A,NEMA 4,Painted steel,Non-fusible,Ungrounded,#14-#2 AWG lug capacity, #14-1/0 AWG solid return,600 Vdc,1,DC Photovoltaic Applications
Product Name
Eaton heavy duty DC disconnect
Catalog Number
DCU1062UPM
UPC
786685557014
Product Length/Depth
10.22 in
Product Height
19.08 in
Product Width
8.76 in
Product Weight
21 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL 98B NEC 690 per UL 1741
Catalog Notes
Not all configurations for ampere rating and number of circuits are available. All circuit configurations can be found in the product dimension tables.
Type
DC disconnect/ungrounded system
Amperage Rating
60 A
Number of circuits
1
Ground
Ungrounded
Maximum voltage
600 VDC
NEMA rating
NEMA 4
Protection
Non-fusible
Application
Solar
Main lug wire size
#14-#2 AWG lug capacity, #14-1/0 AWG solid return
System voltage
600 VDC per pole
Voltage rating
600 VDC
Series
DC Photovoltaic Applications
Enclosure
NEMA 4
Enclosure material
Painted galvanized steel
Fuse configuration
Non-fusible
Switch type
Heavy duty
Protection
Non-fusible
60 A amperage rating and a single circuit configuration provide straightforward field wiring, improving safety by reducing potential fault paths and enabling efficient maintenance workflows on PV arrays. This translates to quicker string isolation during commissioning and routine checks, shortening project timelines while maintaining high reliability. The NEMA 4 enclosure with painted galvanized steel delivers outdoor durability, minimizing corrosion-related downtime and lowering enclosure maintenance costs for rooftop or ground-mounted installations. A 600 VDC rating supports high-voltage DC strings, expanding system design options and reducing the need for additional protective devices on smaller PV configurations. Lug compatibility for #14-#2 AWG and #14-1/0 AWG solid return simplifies wiring, cuts splicing needs, and accelerates field wiring. UL 98B and NEC 690 per UL 1741 certification ensure compliant, risk-mitigated PV system integration across commercial and industrial applications. Catalog notes remind users to consult dimension tables for available configurations, ensuring accurate selection for specific ampacity and circuit counts.

Get a Quick Quote for a Eaton DCU1062UPM

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton DCU1062UPM? Enquire Now

FAQs

Confirm that the DCU1062UPM is installed in a NEMA 4 weatherproof enclosure and that the lug sizing matches your conductors (#14-#2 AWG, #14-1/0 AWG solid return). Verify the single 60 A circuit configuration and that the system voltage does not exceed 600 VDC per pole. Reference the Eaton datasheet for dimension tables to ensure fitment in the planned enclosure footprint.
This unit carries UL 98B and NEC 690 per UL 1741 certifications, aligning with PV safety and performance requirements. Use in applications that demand certified isolation devices for ungrounded PV systems, and ensure installation complies with local electrical codes and utility interconnection standards.
Yes. The enclosure is NEMA 4 rated with painted galvanized steel, designed to withstand outdoor exposure and wet or dusty conditions typical of rooftop and outdoor PV installations, reducing corrosion-related maintenance and extending service life.
This device is specified as an ungrounded, non-fusible DC disconnect. It is intended for ungrounded solar applications where a simple, robust isolation device is required for PV strings, with appropriate protection upstream and in accordance with NEC 690 guidance.
The combination of a single 60 A circuit, durable NEMA 4 enclosure, and UL/NEC compliance reduces maintenance hours during commissioning and service checks. The straightforward wiring with standard lug sizes minimizes field labor, while the non-fusible design lowers replacement risk during fault events, contributing to faster ROI in commercial PV deployments.