Eaton DPF222R Air Conditioning Disconnect - UL Listed 10 kAIC
Part Number: DPF222R
Quick Summary
The Eaton DPF222R air conditioning disconnect provides a reliable, code-compliant isolation point for commercial HVAC systems. Operators and maintenance teams often struggle with compact, weather-resistant enclosures that still offer safe, code-conforming shutoff during start-up. CSA Certified and UL Listed, with a NEMA 3R galvanized steel enclosure, supports outdoor and harsh indoor environments; ANSI 61 gray finish aids visibility in equipment rooms. This disconnect also delivers 60A capacity, 120/240V operation, and 3 hp at 120 V/10 hp at 240 V, enabling straightforward integration with HVAC drives while reducing wiring complexity and inventory costs.
Product Information
Extended Description
DPF222R Eaton: Eaton air conditioning disconnect, Fused pullout, 60A, 120/240V, 10 kAIC, #14-3 Cu/Al 60°C or 75°C, NEMA 3R Galvanized Steel enclosure, 3 hp at 120V, 10 hp at 240V, ANSI 61 gray
Product Name
Eaton air conditioning disconnect
Catalog Number
DPF222R
UPC
782114166932
Product Length/Depth
5.4 in
Product Height
8.7 in
Product Width
3.15 in
Product Weight
2.7 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
CSA Certified UL Listed
Catalog Notes
For replacement pullout head, order part number 96-3258-4.
Type
Fused pullout
Amperage Rating
60A
Horsepower
3 hp at 120 V, 10 hp at 240 V
Voltage rating
120/240 V
Wire size
#14-3 AWG Cu/Al
Color
ANSI 61 gray
Enclosure
NEMA 3R
Enclosure material
Galvanized steel
Interrupt rating
10 kAIC
Residential and Light Commercial, Air Conditioning Disconnects, Volume 1 Tab 6
Eaton Specification Sheet - DPF222R
Feature → Business Impact → Application pattern: The DPF222R uses a fused pullout design rated for 60A, delivering safe, code-compliant isolation during compressor start-up and fault events, reducing panel heat and arc exposure. This directly translates to lower downtime and safer maintenance in light commercial HVAC or industrial cooling installations, such as rooftop units and outdoor condensers. The unit’s 120/240V dual voltage capability supports common HVAC motors and drives, enabling a single part to service multiple units, while simplifying stocking and service logistics in facilities with mixed voltage equipment. The NEMA 3R galvanized steel enclosure provides weather resistance and robust protection against dust and moisture, driving higher uptime and lower corrosion risk in outdoor installations. Its #14-3 Cu/Al conductors and compact footprint simplify field wiring, speeding install and reducing labor costs without compromising safety. With a 10 kAIC interrupt rating, the disconnect withstands high-fault currents; maintenance teams experience fewer nuisance trips and quicker fault isolation, improving overall system reliability. Catalog notes enable a quick replacement pullout head (96-3258-4) to minimize downtime during component wear; this aligns with service contracts demanding rapid turnover. The Eaton DPF222R carries CSA Certification and UL Listing, reinforcing compliance for regulated environments and streamlining procurement across facilities with strict purchasing controls.
Get a Quick Quote for a Eaton DPF222R
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton DPF222R?
Enquire Now
FAQs
The catalog notes indicate replacement pullout head part number 96-3258-4. This head is designed to fit the DPF222R fused pullout assembly, enabling quick field service without replacing the entire disconnect. Ensure the replacement head matches the unit's amperage rating and enclosure to maintain NEMA 3R protection and 10 kAIC interrupt performance.
DPF222R is a 60A fused pullout with a dual voltage rating of 120/240 V. It provides 3 hp at 120 V and 10 hp at 240 V, and features a 10 kAIC interrupt rating for robust fault protection. The conductors supported are #14-3 Cu/Al, compatible with common HVAC components.
Yes. The unit uses a NEMA 3R galvanized steel enclosure with ANSI 61 gray finish, designed for outdoor and damp indoor environments. Its weather-resistant construction helps keep electrical connections protected from rain, dust, and temperature fluctuations, supporting reliable operation of outdoor air conditioning units.
The DPF222R carries CSA Certified and UL Listed marks, indicating compliance with North American safety standards. These certifications simplify regulatory approvals, supplier qualification, and customer audits in regulated sectors, and they support installation in commercial and industrial facilities where compliance with electrical safety codes is mandatory.
Plan for #14-3 Cu/Al conductors and a compliant mounting within a NEMA 3R enclosure. The 60A fused pullout is compatible with 120/240 V HVAC equipment, and the unit’s compact dimensions (5.4 in depth, 8.7 in height, 3.15 in width) simplify indoor crawlspaces or outdoor disconnect enclosures. Ensure adherence to local codes and proper torque on terminations.